TP系列無環流靜止式進相器是襄陽拓邦(bang)電(dian)(dian)氣(qi)自選(xuan)研制開發(fa)的(de)(de)(de)新一(yi)代高新技術產品(pin),是一(yi)種專為(wei)大中(zhong)型繞線式(shi)異步電(dian)(dian)動機設計制作的(de)(de)(de)就(jiu)地無(wu)功功率補償(chang)裝置。它串(chuan)接于(yu)電(dian)(dian)機轉(zhuan)(zhuan)子(zi)回路(lu),改變轉(zhuan)(zhuan)子(zi)電(dian)(dian)流(liu)與(yu)轉(zhuan)(zhuan)子(zi)電(dian)(dian)壓(ya)的(de)(de)(de)相位(wei)關(guan)系,通過磁(ci)場進而改變電(dian)(dian)機定子(zi)電(dian)(dian)流(liu)與(yu)電(dian)(dian)壓(ya)的(de)(de)(de)相位(wei)關(guan)系,達到提(ti)高電(dian)(dian)機自身功率因數、降(jiang)(jiang)低(di)電(dian)(dian)機定子(zi)電(dian)(dian)流(liu)和溫(wen)升的(de)(de)(de)目的(de)(de)(de)。這種方式(shi)從根(gen)本上改善了電(dian)(dian)機的(de)(de)(de)運行狀況,顯著降(jiang)(jiang)低(di)電(dian)(dian)機及電(dian)(dian)網的(de)(de)(de)無(wu)功損耗(hao)(hao),對節能(neng)降(jiang)(jiang)耗(hao)(hao)、降(jiang)(jiang)低(di)單(dan)位(wei)產品(pin)成本,提(ti)高企業的(de)(de)(de)經濟(ji)效益具有重要的(de)(de)(de)意義。
TP系列(lie)無(wu)(wu)環流靜止式進(jin)相(xiang)器對無(wu)(wu)功(gong)功(gong)率的(de)(de)補(bu)償(chang)與(yu)電(dian)(dian)(dian)機(ji)(ji)定(ding)子側并聯電(dian)(dian)(dian)容器的(de)(de)補(bu)償(chang)有著本(ben)質的(de)(de)區別。電(dian)(dian)(dian)容補(bu)償(chang)只是(shi)在電(dian)(dian)(dian)機(ji)(ji)之(zhi)外的(de)(de)電(dian)(dian)(dian)網上對無(wu)(wu)功(gong)進(jin)行(xing)(xing)補(bu)償(chang),減(jian)少電(dian)(dian)(dian)網的(de)(de)無(wu)(wu)功(gong)輸入,電(dian)(dian)(dian)網的(de)(de)功(gong)率因(yin)數得到提(ti)高,但(dan)是(shi)電(dian)(dian)(dian)機(ji)(ji)的(de)(de)無(wu)(wu)功(gong)消耗并沒(mei)有減(jian)少,無(wu)(wu)法改善電(dian)(dian)(dian)機(ji)(ji)本(ben)身的(de)(de)運行(xing)(xing)狀況;而TP系列靜止式進相器是串接(jie)在電機(ji)轉子回路(lu)中,不(bu)僅可顯(xian)著提高功(gong)率因(yin)數,使電機(ji)定子電流大幅度降(jiang)低,而且電機(ji)溫升明顯(xian)降(jiang)低,電機(ji)的(de)效率和過載(zai)能力顯(xian)著提高。
TP系(xi)列靜止式進(jin)相(xiang)(xiang)器(qi)與自(zi)(zi)激(旋轉)式進(jin)相(xiang)(xiang)機(ji)(ji)也不同。TP系(xi)列靜止式進(jin)相(xiang)(xiang)器(qi)采(cai)用了 的(de)(de)(de)交-交變(bian)(bian)頻(pin)技(ji)(ji)術和微(wei)機(ji)(ji)、可控(kong)硅控(kong)制技(ji)(ji)術,可自(zi)(zi)動跟蹤電機(ji)(ji)運行狀(zhuang)態的(de)(de)(de)變(bian)(bian)化并自(zi)(zi)動調整(zheng)相(xiang)(xiang)關參(can)數以達到(dao)佳的(de)(de)(de)補償(chang)效(xiao)果,這是自(zi)(zi)激式進(jin)相(xiang)(xiang)機(ji)(ji)無(wu)法做(zuo)到(dao)的(de)(de)(de)。而(er)且,TP系(xi)列靜止式進(jin)相(xiang)(xiang)器(qi)從根本(ben)上克服了自(zi)(zi)激式進(jin)相(xiang)(xiang)機(ji)(ji)“整(zheng)流(liu)子”結構特別怕塵埃、壽(shou)(shou)命短、維(wei)修頻(pin)繁的(de)(de)(de)缺點;具(ju)有參(can)數調節容(rong)易、主回路無(wu)轉動部件、不怕灰(hui)塵、可靠性高、使用壽(shou)(shou)命長(chang)、維(wei)護(hu)方便(bian),是理想(xiang)的(de)(de)(de)取代自(zi)(zi)激式進(jin)相(xiang)(xiang)機(ji)(ji)的(de)(de)(de)新型高科技(ji)(ji)產品(pin)。
TP系列(lie)靜(jing)止式(shi)進相器可廣泛用(yong)于水(shui)泥、化工、礦山(shan)、冶(ye)金、鋼鐵、造紙、制藥等(deng)行業的大(da)中(zhong)型高(gao)低壓繞線式(shi)異步電機(ji)。
二型號命名
TP系列靜止式進相器型號命(ming)名方(fang)法(fa)如下:
型(xing)號:TP-800,表(biao)示適用于額定轉子電(dian)流(liu)不(bu)超過800A的電(dian)機的靜止式進相器。
三工作(zuo)原理
當電(dian)機運行(xing)進(jin)相(xiang)(xiang)(xiang)時,進(jin)相(xiang)(xiang)(xiang)器通過(guo)轉(zhuan)子(zi)(zi)電(dian)流傳感器采(cai)集到的(de)(de)(de)(de)轉(zhuan)子(zi)(zi)電(dian)流信號及(ji)工頻(pin)(pin)電(dian)壓(ya)提供的(de)(de)(de)(de)同(tong)步信號經(jing)微處理器CPU進(jin)行(xing)數(shu)據和(he)相(xiang)(xiang)(xiang)位(wei)(wei)處理,控制可(ke)控硅的(de)(de)(de)(de)觸發信號,調整由12只晶閘(zha)管組成的(de)(de)(de)(de)交—交變(bian)頻(pin)(pin)裝置(zhi),將降壓(ya)后的(de)(de)(de)(de)工頻(pin)(pin)電(dian)源變(bian)為(wei)和(he)轉(zhuan)子(zi)(zi)電(dian)流同(tong)頻(pin)(pin)率,相(xiang)(xiang)(xiang)位(wei)(wei)滯后90°的(de)(de)(de)(de)附加電(dian)勢加在電(dian)機轉(zhuan)子(zi)(zi)回路(lu)中(zhong)。轉(zhuan)子(zi)(zi)的(de)(de)(de)(de)電(dian)流和(he)電(dian)壓(ya)相(xiang)(xiang)(xiang)位(wei)(wei)因(yin)此(ci)改變(bian),通過(guo)磁場(chang)進(jin)而改變(bian)電(dian)機定子(zi)(zi)電(dian)流與定子(zi)(zi)電(dian)壓(ya)的(de)(de)(de)(de)相(xiang)(xiang)(xiang)位(wei)(wei)角,使電(dian)機的(de)(de)(de)(de)功率因(yin)數(shu)提高,得到補償(chang)。
當電機在某一負載下(xia)(xia)運(yun)行時(shi),其轉(zhuan)子電流(liu)為I2e、定子電流(liu)為I1e, 向量圖如下(xia)(xia)所示。
從(cong)電(dian)(dian)機(ji)學我們知道,激磁(ci)電(dian)(dian)流Im由(you)關系(xi)式(shi)Im=I1e-I2e,從(cong)向量圖(tu)可(ke)得出Im。當(dang)進相(xiang)器的(de)(de)(de)(de)電(dian)(dian)勢疊加在轉子回(hui)路(lu)后,轉子電(dian)(dian)流的(de)(de)(de)(de)相(xiang)位(wei)變(bian)為圖(tu)中的(de)(de)(de)(de)I2。由(you)于負載不變(bian),激磁(ci)電(dian)(dian)流Im不變(bian)。此時的(de)(de)(de)(de)定子電(dian)(dian)流I1由(you)關系(xi)式(shi)I1=Im+I2從(cong)向量圖(tu)可(ke)得出I1,如圖(tu)所示(shi)。從(cong)圖(tu)中可(ke)以(yi)看(kan)出I1的(de)(de)(de)(de)功率因數角和幅值都比I1e小,說明(ming)電(dian)(dian)機(ji)的(de)(de)(de)(de)功率因數有所提(ti)高,定子電(dian)(dian)流有所下降(jiang)。
進(jin)相(xiang)器(qi)就(jiu)是(shi)這樣改(gai)變轉(zhuan)子(zi)電(dian)流(liu)與轉(zhuan)子(zi)電(dian)壓的相(xiang)位(wei)關系,通過磁場進(jin)而改(gai)變電(dian)機(ji)定(ding)(ding)子(zi)電(dian)流(liu)與定(ding)(ding)子(zi)電(dian)壓的相(xiang)位(wei)關系,減小功率因數角(jiao),終(zhong)使電(dian)機(ji)本身的功率因數得(de)以提(ti)高,定(ding)(ding)子(zi)電(dian)流(liu)得(de)以下降,達到對電(dian)機(ji)補償(chang)的目的。
當負(fu)載發生改(gai)變(bian)時,微處理器(qi)實時檢測電機(ji)參數的變(bian)化(hua),并根據負(fu)載的變(bian)化(hua),動態調整附加在轉子上的電勢幅值,以使電機(ji)的功率因數始終(zhong)保持在期望(wang)值上。
四原理框(kuang)圖(tu)
電容式補償(chang)的矢(shi)量分析:
電容補償和進相器補償的原理圖分別如下:
圖(tu)中,將(jiang)電(dian)(dian)機(ji)(ji)(ji)進(jin)行了等(deng)(deng)(deng)效(xiao)簡化,R1、X1為(wei)(wei)電(dian)(dian)機(ji)(ji)(ji)定子等(deng)(deng)(deng)效(xiao)電(dian)(dian)路(lu)的(de)電(dian)(dian)阻和(he)(he)電(dian)(dian)感,R2、X2為(wei)(wei)電(dian)(dian)機(ji)(ji)(ji)轉子等(deng)(deng)(deng)效(xiao)電(dian)(dian)路(lu)的(de)電(dian)(dian)阻和(he)(he)電(dian)(dian)感,C為(wei)(wei)就(jiu)地補(bu)償的(de)電(dian)(dian)容,Uf為(wei)(wei)進(jin)相器的(de)等(deng)(deng)(deng)效(xiao)電(dian)(dian)路(lu),M為(wei)(wei)電(dian)(dian)機(ji)(ji)(ji)的(de)接(jie)線點(dian)。
從(cong)圖可(ke)以看出,靜止式(shi)(shi)進(jin)相器和電容補(bu)償(chang)(chang)(chang)對電機(ji)的作(zuo)用點不同(tong),電容是(shi)在電機(ji)的前端(duan)(duan)定子側進(jin)行(xing)補(bu)償(chang)(chang)(chang),其(qi)補(bu)償(chang)(chang)(chang)范圍是(shi)在補(bu)償(chang)(chang)(chang)點的前端(duan)(duan);靜止式(shi)(shi)進(jin)相器串(chuan)聯在電機(ji)的后端(duan)(duan),其(qi)補(bu)償(chang)(chang)(chang)范圍擴大到了電機(ji)。
五性能特(te)點
1、可使電機的功率因數提高到0.95以上,無功功率降(jiang)低60%以上。
2、降低定子電(dian)流10%-20%。
3、降低(di)線損、銅損20%-30%。
4、電(dian)機溫升降低5%。
5、過載能力和效率大大提高(gao),電機使用壽(shou)命延(yan)長。
6、具(ju)有故障(zhang)自動(dong)保護(hu)功(gong)能,保障(zhang)設備長期安全運行(xing)。
7、操(cao)作簡單,安裝調試和維修(xiu)保養均不影響正常(chang)生產,半年內可收回成本。
六使用條件
1、安裝地點環境(jing)溫(wen)度≤40℃
2、安裝地點相對濕度≤90%
3、 安裝(zhuang)地點無火災、爆炸危險品,無化學(xue)腐蝕及劇烈振(zhen)動(dong)。
4、海拔高(gao)度(du)≤1500M。
5、進相(xiang)器(qi)(qi)柜體上方0.5米(mi)內應通(tong)風;如無地溝(gou),須將進相(xiang)器(qi)(qi)柜體架空0.1米(mi)。
注(zhu):TP系列(lie)靜止式進(jin)相(xiang)器應滿足上方(fang)要求(qiu)的(de)使用條件,襄陽拓邦電氣還(huan)可(ke)提供(gong)適(shi)用于(yu)高(gao)原地區(海拔超過1500米)的靜止式進相器(但用戶須事先特別申請)。
七技術(shu)參數(shu)
進 相 器 型 號 |
適 配 電 機 參 數 |
|
額定轉子電流(A) |
額定功率(KW) |
|
TP-400 |
≤400 |
95-800 |
TP-500 |
400-500 |
245-1000 |
TP-600 |
500-600 |
315-1250 |
TP-800 |
600-800 |
630-1600 |
TP-1000 |
800-1000 |
1000-2000 |
TP-1200 |
1000-1200 |
1600-2500 |
TP-1500 |
1200-1500 |
2000以上 |
八安裝尺寸
1、外(wai)型尺寸圖
2、安裝基礎圖
3、規(gui)格尺寸(cun)表
型(xing)號 |
外形尺寸(MM) |
安裝尺寸(MM) |
||||
寬(W) |
深(D) |
高(H) |
寬(E) |
深(F) |
螺孔 |
|
TP400-600 |
1000 |
760 |
2000 |
780 |
620 |
14 |
TP800-1000 |
1100 |
800 |
2000 |
880 |
650 |
14 |
TP1200-1500 |
1200 |
900 |
2200 |
980 |
750 |
16 |
注(zhu):隨著產(chan)(chan)品不斷更新換代(dai),外形及(ji)安裝(zhuang)尺寸會有所變(bian)化,請以具體的產(chan)(chan)品為準。
九安裝調試
(一(yi))安(an)裝
1、將進(jin)(jin)相器(qi)搬到安裝位置(zhi),注意進(jin)(jin)相器(qi)柜(ju)體底部應(ying)與地溝相通或架空,首先(xian)是打開柜(ju)子的前后門,從上到下,逐一地擰緊螺(luo)絲,防止在運輸過(guo)程中螺(luo)絲松動造成(cheng)進(jin)(jin)相器(qi)不能正常工(gong)作。
2、準備好(hao)(hao)連(lian)接【主電(dian)機(ji)轉(zhuan)子至進(jin)(jin)相(xiang)(xiang)器(qi)(qi)接觸(chu)器(qi)(qi)KM13的三(san)(san)根電(dian)纜(lan)】、【進(jin)(jin)相(xiang)(xiang)器(qi)(qi)接觸(chu)器(qi)(qi)KM11至主電(dian)機(ji)起(qi)動柜的三(san)(san)根電(dian)纜(lan)】,其(qi)線(xian)徑應能承(cheng)載(zai)主電(dian)機(ji)轉(zhuan)子額定電(dian)流,比(bi)好(hao)(hao)長(chang)度并壓好(hao)(hao)接頭。
3、進(jin)相(xiang)(xiang)器(qi)上(shang)的(de)電(dian)(dian)流(liu)(liu)(liu)(liu)表(biao)、功(gong)率因數表(biao)是(shi)直接從(cong)電(dian)(dian)機(ji)定子回路上(shang)的(de)電(dian)(dian)流(liu)(liu)(liu)(liu)互(hu)(hu)感(gan)(gan)(gan)器(qi)、電(dian)(dian)壓(ya)互(hu)(hu)感(gan)(gan)(gan)器(qi)取信(xin)號,要求所用電(dian)(dian)流(liu)(liu)(liu)(liu)互(hu)(hu)感(gan)(gan)(gan)器(qi)副邊的(de)額定電(dian)(dian)流(liu)(liu)(liu)(liu)為(wei)5A、電(dian)(dian)壓(ya)互(hu)(hu)感(gan)(gan)(gan)器(qi)副邊的(de)額定電(dian)(dian)壓(ya)為(wei)100V,若(ruo)用戶現用的(de)不滿足(zu)該要求,則須另行準(zhun)備(bei)符合上(shang)述要求的(de)互(hu)(hu)感(gan)(gan)(gan)器(qi)。(注:電(dian)(dian)壓(ya)互(hu)(hu)感(gan)(gan)(gan)器(qi)僅適用于高壓(ya)電(dian)(dian)機(ji),對低壓(ya)電(dian)(dian)機(ji),進(jin)相(xiang)(xiang)器(qi)電(dian)(dian)壓(ya)信(xin)號直接從(cong)定子回路取)
4、新電(dian)機(ji)(ji)須(xu)帶上90%以(yi)上負(fu)載并正(zheng)(zheng)常(chang)(chang)運轉(zhuan)(zhuan)后(hou)才可調(diao)試進相器,用戶(hu)在(zai)通知我(wo)方(fang)調(diao)試前,應調(diao)試好(hao)電(dian)機(ji)(ji)、減速機(ji)(ji)、磨機(ji)(ji)等(deng)其它設(she)備,使其帶上負(fu)載正(zheng)(zheng)常(chang)(chang)運轉(zhuan)(zhuan),以(yi)免延(yan)誤進相器調(diao)試時(shi)間(jian)。
5、各聯鎖線意(yi)義(yi)如下:
(225、227)取(qu)自(zi)電機起動(dong)柜星(xing)點短(duan)接(jie)接(jie)觸器(qi)的輔助常(chang)開點,只(zhi)有在電機起動(dong)完畢后,進相器(qi)才(cai)可(ke)以進相。
(355、357)當開(kai)關柜(ju)主(zhu)開(kai)關是(shi)接(jie)觸器時(shi)與(yu)分閘按鈕并聯(lian);是(shi)斷路(lu)器時(shi)與(yu)分閘按鈕串聯(lian), 進(jin)相狀態下(xia)主(zhu)電(dian)機不能停(ting)機,只有先退相才能停(ting)主(zhu)機。
(359、361)串入(ru)開關柜(ju)合(he)閘回(hui)路。當(dang)KM11吸(xi)合(he)時,可以起動電機。
(363、369)從起動(dong)柜控(kong)制電(dian)源引單相380V,使KM11與(yu)起動(dong)柜控(kong)制回路同時得電(dian)。
(30、32)串入主電(dian)(dian)(dian)機電(dian)(dian)(dian)流(liu)(liu)計量(liang)回路;(40、42)并入主電(dian)(dian)(dian)機電(dian)(dian)(dian)壓計量(liang)回路。(取A相電(dian)(dian)(dian)流(liu)(liu)則取B,C相電(dian)(dian)(dian)壓,如此類(lei)推,電(dian)(dian)(dian)流(liu)(liu)和電(dian)(dian)(dian)壓不得取同相)。
(A、B、C、N)接三(san)相四線電源,導(dao)線橫截面(mian)積:TP600以(yi)下用(yong)4mm2;TP1000以(yi)下用(yong)6mm2;TP1500以(yi)下用(yong)10mm2。
6、控(kong)制器所有指(zhi)示燈的含義說明如下:
(1)主板(中間一塊)的指示燈(從上往下數)
●L1、L2、L3:電(dian)(dian)機(ji)轉(zhuan)子三(san)相電(dian)(dian)流信號指示(shi)(電(dian)(dian)機(ji)運轉(zhuan)時為循環(huan)顯示(shi)狀態;自檢試驗時為隨機(ji)狀態:或(huo)亮、或(huo)滅)
●L4:+5V電源(yuan)指示(保持亮的狀(zhuang)態)
●L5:熱故障(zhang)指示(有熱故障(zhang)時L5滅)
●L6:缺(que)相及自動故障保護指示(shi)(有(you)缺(que)相故障及其(qi)它故障時L6燈滅)
●L7:+15V電源指示(shi)(保(bao)持亮(liang)的狀態)
●L8:-15V電(dian)源指示(shi)(保持(chi)亮的狀態)
(2)驅動板(兩邊兩塊)
●分別(bie)代表12個可控(kong)制硅的觸發(fa)信號(指(zhi)示燈均亮,并有規律的閃爍(shuo))
(二)試驗
1、檢查主電纜、聯鎖(suo)線、儀表(biao)線連接是否正確。
2、檢查各(ge)器件(jian)螺絲(si)是否緊(jin)固。
3、用(yong)萬用(yong)表測量可控硅極(ji)間(jian)電阻:
●觸(chu)發極G與陰極K間(jian)電阻為幾(ji)十歐姆;
●觸(chu)發極G與陽極A間(jian)電阻大于幾(ji)十千歐;
●陰極(ji)K與(yu)陽極(ji)A間電阻大于幾十千歐;
●陰極(ji)K與陽極(ji)A用萬用表200K檔(dang)測量,阻值應從小變化到(dao)無限大(da)。
4、合(he)(he)(he)上(shang)(shang)起(qi)動柜電源(yuan),進相器背面的接觸器KM11應(ying)(ying)吸合(he)(he)(he),短接225、227;合(he)(he)(he)上(shang)(shang)進相器電源(yuan),電源(yuan)指示(shi)燈亮(liang);控制器應(ying)(ying)有電,控制器上(shang)(shang)指示(shi)燈亮(liang)。
5、控制(zhi)器上(shang)(shang)撥碼開關打在ON(上(shang)(shang)方(fang))位置(zhi),中(zhong)間主板L1、L2、L3循(xun)環亮或滅,L4~L8全(quan)亮;兩邊兩塊驅動板指示燈閃爍。
6、按綠色(se)(se)進相(xiang)按鈕(niu),進相(xiang)器(qi)前面(mian)的接(jie)觸(chu)器(qi)KM13吸合,延時(shi)后,背面(mian)的接(jie)觸(chu)器(qi)KM11斷開(kai),綠色(se)(se)進相(xiang)指示燈亮,風(feng)機運轉,風(feng)應(ying)向上吹,主變壓器(qi)副(fu)邊(bian)電(dian)流不超過(guo)30A,并(bing)且(qie)沒有大幅度變化(hua)。
7、按紅(hong)色退相(xiang)按鈕,進(jin)相(xiang)器后(hou)(hou)面(mian)的接觸(chu)器KM11吸(xi)合,延時后(hou)(hou),前面(mian)的接觸(chu)器KM13斷開,綠(lv)色進(jin)相(xiang)指示燈滅,紅(hong)色電源指示燈亮,進(jin)相(xiang)器即(ji)退出進(jin)相(xiang)狀態。
8、通電試驗結束,請務必斷開225、227。
(三)調試(shi)
1、運行(xing)前:控制器主板(ban)上撥碼開(kai)關應打在OFF(下(xia)方)位(wei)置。
2、起動主電機:打(da)開(kai)(kai)進相器前柜門,合上(shang)空(kong)氣開(kai)(kai)關,進相器電源接通(tong),面板上(shang)的紅色電源指(zhi)示(shi)燈亮,關閉柜門,等待主機起動。
3、進(jin)相(xiang):(1)電機正(zheng)常運(yun)轉后,按(an)(an)綠色(se)進(jin)相(xiang)按(an)(an)鈕(niu),進(jin)相(xiang)器(qi)前面的接觸器(qi)KM13吸(xi)合,延(yan)時后,背面的接觸器(qi)KM11斷(duan)開,綠色(se)進(jin)相(xiang)指示燈亮,風機運(yun)轉,定子(zi)電流應下降,功(gong)率因數(shu)應上升。如(ru)果(guo)定子(zi)電流不下降反(fan)而上升,調整同步(bu)變壓器(qi)上6V、6V0兩線的位(wei)置,再進(jin)相(xiang)。
(2)測量主(zhu)變壓(ya)器(qi)原、副邊電流,應無(wu)大幅度擺動。
(3)電機(ji)定子電流應平穩(wen),無大幅度(du)擺動。
(4)六個電(dian)抗(kang)器(qi)上端銅(tong)排的電(dian)流擺(bai)動幅度應一(yi)致。
4、退(tui)相(xiang):按(an)紅色(se)退(tui)相(xiang)按(an)鈕,進相(xiang)器后面的(de)接(jie)觸(chu)器KM11吸合,延時后,前面的(de)接(jie)觸(chu)器KM13斷開(kai),綠色(se)進相(xiang)指(zhi)示燈滅(mie),紅色(se)電(dian)源指(zhi)示燈亮,進相(xiang)器即退(tui)出(chu)進相(xiang)狀態。
5、停車:進相器退相后,按下主機(ji)停車按鈕,電機(ji)即停車。
(四)測量和觀察
1、測(ce)量可控(kong)硅、銅排、交流(liu)接觸器(qi)、電抗器(qi)、主變壓器(qi)、控(kong)制(zhi)板溫度。
2、測量可控(kong)硅觸(chu)發電壓;主變(bian)壓器(qi)一次、二(er)次電流;電抗(kang)器(qi)輸入電流。
3、觀(guan)察風(feng)機(ji)運行情況。
4、觀察整體運(yun)行(xing)情況,有(you)(you)無(wu)異常響聲或銅(tong)排有(you)(you)無(wu)大的抖(dou)動現象等(deng)。
十使用維(wei)護(hu)
為確保TP系列靜止式進相器長期安全、可靠地運行,請操(cao)作人員特別注意以(yi)下事(shi)項:
1、嚴(yan)禁在(zai)進(jin)相器運行期(qi)間(jian),切斷(duan)進(jin)相器外部電源。
2、定期檢查冷卻風(feng)(feng)機運轉狀況,冷卻風(feng)(feng)機停(ting)轉使可(ke)控硅散熱(re)能力下降,可(ke)能燒壞可(ke)控硅。
3、定期檢(jian)測(ce)主(zhu)變壓器原(yuan)、副邊運行電流。
4、定期(qi)檢測可控硅(gui)、聯接(jie)銅排、交流接(jie)觸器、電抗(kang)器、主變壓器、控制板的溫度。
5、定期(qi)檢修主回路(lu)接觸(chu)器(qi)的觸(chu)頭(tou)。真空接觸(chu)器(qi)定期(qi)檢測絕(jue)緣電阻,用5KV或2.5KV搖(yao)表檢查,當(dang)開關管絕(jue)緣電阻小(xiao)于100兆(zhao)歐時,應加強監(jian)視,小(xiao)于20兆(zhao)歐時應立(li)即更換新(xin)管,以延長(chang)接觸(chu)器(qi)的使(shi)用壽命,保障(zhang)進(jin)相器(qi)及電機(ji)安全運行。
6、當進相器停用一段時(shi)間又重新啟用時(shi), 次(ci)進相前應觀察柜內控制單元上各(ge)指示(shi)(shi)燈(deng)是否正常(chang)。電機起動并正常(chang)運(yun)轉后,各(ge)指示(shi)(shi)燈(deng)顯示(shi)(shi)如下:
·主(zhu)板(中(zhong)間(jian)一塊):除L1,L2,L3周期性(xing)循環顯示(shi)外(注意:此指(zhi)電機在(zai)運(yun)轉時的(de)狀態(tai),若電機未轉,該(gai)三燈為隨(sui)機狀態(tai)),其它各(ge)燈均亮。
·驅動(dong)扳(兩(liang)邊(bian)的兩(liang)塊):其上(shang)面各指示燈均亮并(bing)有輕微(wei)閃爍。
7、當電機定子電流出(chu)(chu)現異(yi)常大幅擺動時,應立(li)即退相,查出(chu)(chu)原因并檢修后投(tou)入使用(yong)。
8、定期(qi)打掃柜內衛生。
十一故障處理
主電機不能起動 |
端子363、369無380V 電源 |
檢查起(qi)動柜控制電源 |
||
|
接觸器KM11不吸合 |
檢查KM11線包及其控制回路 |
||
|
接觸器KM11吸合,但其輔助觸點未閉合 |
檢(jian)修其輔助觸點 |
||
|
端子359、361串入合閘回路的線未接通 |
檢(jian)查該回路 |
||
不能投入進相 |
空氣開關QF1、QF2、QF3沒合上 |
合上(shang)空(kong)氣開關 |
||
|
按鈕STP、ST接觸不良 |
|
||
|
中間繼電器KA11觸點接觸不良 |
|
||
|
主電機起動柜內星點接觸器常開輔助觸點不能閉合(225、227未接通) |
檢修該接觸器輔助觸點及連線(xian) |
||
|
KM13不(bu)能吸合 |
檢查KM13線包及其控制回路 |
||
|
固態繼電器FV損壞或者不導通 |
控制器主控制板L6燈滅 |
檢查主控板7腳對11、12、13腳有無+、-3伏左右電壓,否則更換電流傳感器 |
|
|
|
檢查固態繼電器FV |
FV的3、4腳有直流15V電(dian)壓,而323、325不(bu)通(tong),須(xu)更換(huan)該繼(ji)電(dian)器(qi) |
|
進(jin)相后主電機停機 |
接入開關柜的KM11、KM13的輔助觸點359、361接觸不好 |
維修(xiu)該觸(chu)點 |
||
|
進相(xiang)器投(tou)入進相(xiang)瞬間(jian)外部空氣開關跳閘 |
更(geng)換大規格的空氣開(kai)關 |
||
進相后無效果 |
接(jie)入主控板的電流傳(chuan)感器信號線錯誤 |
電流傳感器從左到右TA1、TA2、TA3的信號線應分別對應與主控板的13、12、11腳 |
||
|
主控板的(de)撥碼開(kai)關在自檢位 |
撥(bo)碼(ma)開關(guan)撥(bo)至工作位 |
||
|
KM13吸合(he)后KM11未(wei)釋(shi)放(時(shi)間繼電(dian)器KT11壞) |
更換KT11時間繼電器 |
||
|
KM15沒有吸合 |
KM11的輔助觸(chu)點301、305接(jie)觸(chu)不良(liang) |
維(wei)修該觸點(dian) |
|
|
|
KM15線圈(quan)故障 |
更換KM15線圈 |
|
|
KM15主(zhu)觸點接(jie)觸不(bu)良 |
更換KM15 |
||
|
主(zhu)變壓器(qi)原邊開路(lu) |
更換主(zhu)變壓(ya)器 |
||
進相后(hou)主電機(ji)電流不減反增 |
同步電(dian)源相序(xu)錯誤 |
調換進相器內小變壓器TC上輸出6V、6V0電壓的兩線位置 |
||
|
電機轉速(su)下降(缺相),自動退相 |
KM13主觸點接(jie)觸不良 |
維修該觸(chu)點 |
|
|
|
電機轉子線松動,進相時的電流(liu)沖(chong)擊導致(zhi)缺相 |
檢查電機(ji)轉子線 |
|
進相后主(zhu)電機電流擺動大 |
可控硅擊穿 |
測量(liang)可控硅極(ji)間電(dian)阻(zu)(詳細方法見調(diao)試部分(fen)) |
||
|
觸發板損(sun)壞 |
測量可控硅控制極與陰極之間應有0.2V以上的直流電壓信號,否則應檢查觸發板 |
||
|
主板的撥碼(ma)開關在自檢(jian)位 |
撥碼開(kai)關撥至工作位 |
||
|
電機轉子(zi)線松動 |
檢查電機轉(zhuan)子線(xian) |
||
|
當KM13采用節能型線圈時,線圈故障導致KM13進行瞬間來回釋放、吸合,導致主回路接觸不良 |
維修或更換KM13線圈 |
注意:進相器檢修不得在進相狀(zhuang)態下(xia)進行,發(fa)現(xian)問題(ti)應立(li)即退(tui)相。
十二(er)控(kong)制板檢修
現(xian)象(xiang) |
原因 |
對策 |
L1、L2、L3不循環閃爍,L6滅,其它各燈正常 |
轉子缺相 |
檢查接觸器KM2主觸頭是否損壞,若損壞,則維修觸頭或更換接觸器 |
電流傳感器器損壞 |
檢查電流傳感器是否有±2V以上的輸出信號,否則更換傳感器 |
|
主(zhu)控板元器件(jian)損壞 |
依次更換IC210、IC211 |
|
L1、L2、L3不周期性閃爍,其它各燈正常 |
主控(kong)板元器(qi)件損壞 |
依次更換IC210、IC211、IC205、IC207 |
L6滅,其它各燈正常 |
主控(kong)板元器件損(sun)壞(huai) |
依次更換IC207、IC209 |
L5滅,其它各燈正常 |
散熱器(qi)溫度檢測回路故障 |
檢查(cha)溫度開關(guan)及其連線 |
L4、L7、L8全部或部分滅 |
電(dian)源(yuan)故障 |
1、檢查變壓器及控制板是否有±18V電源 2、更換相應的7805、7815、7915 |
F1-L1~L6 或F2-L1~L6部分指示燈亮,主板各燈正常 |
觸發(fa)板元器件損壞 |
1、有一片ULN2004損壞,更換之 2、脈沖變壓器接觸不良,作相應處理 |
F1-L1~L6 或F2-L1~L6指示燈全滅,主板各燈正常 |
觸發板元器件損壞(huai) |
1、兩片ULN2004損壞,更換之 2、更換555芯片 |
觸發(fa)板無電源(yuan) |
1、檢查主板7815是否有虛焊 2、檢查觸發板19腳與主板6腳連接是否正常 |
十三(san)注意事項(xiang)
1、進相器(qi)檢修應在退相狀(zhuang)態下(xia)進行,發現問題(ti)應立即退相。
2、嚴禁隨意帶電插(cha)拔控制板,檢修控制板時,一(yi)定要把空開QF3打(da)下(xia)來。
3、更換可(ke)控硅(gui)(gui)時應注意陰、陽極的方向(xiang),并壓緊散(san)熱器(壓力(li)不要過(guo)大(da)),裝上后擰緊所有螺絲,之后再檢測可(ke)控硅(gui)(gui)各極間的電阻情況。若一只可(ke)控硅(gui)(gui)擊穿在柜(ju)體上直(zhi)接檢測,同一相(xiang)的四(si)個(ge)可(ke)控硅(gui)(gui)均(jun)顯示(shi)擊穿,此時應把該(gai)組可(ke)控硅(gui)(gui)間的聯接銅排拆掉再測 。
十四訂(ding)貨須(xu)知
1、提(ti)供電(dian)(dian)機型號(hao)、額定(ding)功(gong)率、定(ding)子電(dian)(dian)壓、定(ding)子電(dian)(dian)流、轉子電(dian)(dian)壓、轉子電(dian)(dian)流、額定(ding)功(gong)率因數(shu)。
2、提供電機(ji)拖動負(fu)載的特征及負(fu)載率(lv)。
預知TP系列無環流靜止式進相器的更(geng)多信(xin)息,請撥打襄陽(yang)拓邦(bang)電(dian)氣官(guan)網(wang)電(dian)話: 鄭經理17771133316或咨詢網(wang)站客服!!