欧美最猛性XXXXX69交_亚洲精品无码永久电影在线_欧美黑人粗大xxxxbbbb_中文字幕日韩精品有码视频

張家界產品中心
張家界產品中心

張家界產品中心

product

張家界TP系列靜止式進相器

一概述(shu)TP系列無環流靜止(zhi)式進(jin)相器(qi)是襄陽拓邦(bang)電氣自選研制開發的新一代高新技術產品,是一種專為大中型繞線式異……

相關內容
在線留言
詳情內容
content details

TP系列無環流靜止式進相器是(shi)襄陽(yang)拓邦電(dian)(dian)(dian)(dian)氣自(zi)(zi)選(xuan)研(yan)制開發的(de)(de)新(xin)一(yi)代高(gao)新(xin)技術產(chan)品,是(shi)一(yi)種(zhong)專(zhuan)為大中型繞(rao)線式(shi)異步電(dian)(dian)(dian)(dian)動機(ji)(ji)設計制作的(de)(de)就地無功功率(lv)補償裝置(zhi)。它串接于(yu)電(dian)(dian)(dian)(dian)機(ji)(ji)轉(zhuan)(zhuan)子(zi)回(hui)路,改(gai)變(bian)(bian)轉(zhuan)(zhuan)子(zi)電(dian)(dian)(dian)(dian)流(liu)與轉(zhuan)(zhuan)子(zi)電(dian)(dian)(dian)(dian)壓的(de)(de)相位(wei)關(guan)系,通過磁(ci)場進而改(gai)變(bian)(bian)電(dian)(dian)(dian)(dian)機(ji)(ji)定(ding)子(zi)電(dian)(dian)(dian)(dian)流(liu)與電(dian)(dian)(dian)(dian)壓的(de)(de)相位(wei)關(guan)系,達到(dao)提高(gao)電(dian)(dian)(dian)(dian)機(ji)(ji)自(zi)(zi)身(shen)功率(lv)因數(shu)、降低電(dian)(dian)(dian)(dian)機(ji)(ji)定(ding)子(zi)電(dian)(dian)(dian)(dian)流(liu)和溫升(sheng)的(de)(de)目的(de)(de)。這種(zhong)方式(shi)從根本上改(gai)善了電(dian)(dian)(dian)(dian)機(ji)(ji)的(de)(de)運行狀(zhuang)況(kuang),顯著降低電(dian)(dian)(dian)(dian)機(ji)(ji)及電(dian)(dian)(dian)(dian)網的(de)(de)無功損耗(hao),對節能降耗(hao)、降低單(dan)位(wei)產(chan)品成本,提高(gao)企(qi)業的(de)(de)經濟效益具有重要的(de)(de)意義。


TP系列無(wu)環流靜(jing)止式(shi)進(jin)相器(qi)對無(wu)功(gong)(gong)功(gong)(gong)率(lv)的(de)補(bu)償與電(dian)機(ji)定(ding)子(zi)側并聯電(dian)容器(qi)的(de)補(bu)償有著本(ben)質的(de)區別(bie)。電(dian)容補(bu)償只是在(zai)電(dian)機(ji)之(zhi)外(wai)的(de)電(dian)網上對無(wu)功(gong)(gong)進(jin)行(xing)補(bu)償,減少電(dian)網的(de)無(wu)功(gong)(gong)輸入,電(dian)網的(de)功(gong)(gong)率(lv)因(yin)數得(de)到提(ti)高,但是電(dian)機(ji)的(de)無(wu)功(gong)(gong)消耗并沒有減少,無(wu)法改善電(dian)機(ji)本(ben)身的(de)運行(xing)狀況;而TP系列靜止式進相器是串接(jie)在電機(ji)(ji)轉(zhuan)子(zi)回路中,不僅(jin)可顯(xian)著(zhu)提高(gao)功(gong)率(lv)因(yin)數,使電機(ji)(ji)定子(zi)電流大(da)幅度(du)降低(di),而且電機(ji)(ji)溫升明(ming)顯(xian)降低(di),電機(ji)(ji)的效率(lv)和過載能力顯(xian)著(zhu)提高(gao)。

TP系列靜止(zhi)式(shi)進(jin)相(xiang)器與自(zi)(zi)激(ji)(ji)(旋(xuan)轉)式(shi)進(jin)相(xiang)機(ji)(ji)也不同。TP系列靜止(zhi)式(shi)進(jin)相(xiang)器采用了(le) 的(de)(de)交(jiao)-交(jiao)變頻技術和(he)微(wei)機(ji)(ji)、可控(kong)硅控(kong)制技術,可自(zi)(zi)動(dong)跟(gen)蹤電(dian)機(ji)(ji)運行狀態的(de)(de)變化并(bing)自(zi)(zi)動(dong)調(diao)整相(xiang)關(guan)參數(shu)以達到(dao)佳的(de)(de)補償效果,這(zhe)是自(zi)(zi)激(ji)(ji)式(shi)進(jin)相(xiang)機(ji)(ji)無(wu)法做到(dao)的(de)(de)。而且,TP系列靜止(zhi)式(shi)進(jin)相(xiang)器從(cong)根本上(shang)克服了(le)自(zi)(zi)激(ji)(ji)式(shi)進(jin)相(xiang)機(ji)(ji)“整流子”結構(gou)特別怕塵埃、壽命短、維修頻繁(fan)的(de)(de)缺點(dian);具有參數(shu)調(diao)節容易、主回(hui)路無(wu)轉動(dong)部件、不怕灰(hui)塵、可靠性高、使用壽命長、維護(hu)方便,是理(li)想的(de)(de)取代自(zi)(zi)激(ji)(ji)式(shi)進(jin)相(xiang)機(ji)(ji)的(de)(de)新型高科技產品(pin)。

TP系列靜(jing)止式(shi)進相器(qi)可廣泛(fan)用于水泥、化工、礦山、冶金(jin)、鋼鐵、造紙、制(zhi)藥等行業(ye)的大中型高低壓繞(rao)線式(shi)異步(bu)電機。


二(er)型號命名

TP系列靜止式進相器型號命名方法如下:





型號:TP-800,表示適(shi)用于(yu)額定轉子電(dian)流(liu)不(bu)超過800A的電(dian)機的靜止式進相器。


三(san)工作原理

當電(dian)(dian)(dian)(dian)(dian)機運行(xing)(xing)進(jin)(jin)相(xiang)(xiang)時,進(jin)(jin)相(xiang)(xiang)器(qi)通(tong)過(guo)轉子電(dian)(dian)(dian)(dian)(dian)流傳感(gan)器(qi)采集(ji)到(dao)的(de)(de)(de)轉子電(dian)(dian)(dian)(dian)(dian)流信(xin)號(hao)及工(gong)(gong)頻(pin)電(dian)(dian)(dian)(dian)(dian)壓提(ti)供的(de)(de)(de)同步信(xin)號(hao)經微處理(li)器(qi)CPU進(jin)(jin)行(xing)(xing)數(shu)據(ju)和相(xiang)(xiang)位(wei)處理(li),控制可(ke)控硅的(de)(de)(de)觸發(fa)信(xin)號(hao),調整由(you)12只(zhi)晶閘管(guan)組成的(de)(de)(de)交—交變(bian)(bian)頻(pin)裝置,將降壓后的(de)(de)(de)工(gong)(gong)頻(pin)電(dian)(dian)(dian)(dian)(dian)源變(bian)(bian)為和轉子電(dian)(dian)(dian)(dian)(dian)流同頻(pin)率,相(xiang)(xiang)位(wei)滯后90°的(de)(de)(de)附(fu)加(jia)電(dian)(dian)(dian)(dian)(dian)勢(shi)加(jia)在電(dian)(dian)(dian)(dian)(dian)機轉子回路中。轉子的(de)(de)(de)電(dian)(dian)(dian)(dian)(dian)流和電(dian)(dian)(dian)(dian)(dian)壓相(xiang)(xiang)位(wei)因(yin)此改變(bian)(bian),通(tong)過(guo)磁場進(jin)(jin)而(er)改變(bian)(bian)電(dian)(dian)(dian)(dian)(dian)機定子電(dian)(dian)(dian)(dian)(dian)流與定子電(dian)(dian)(dian)(dian)(dian)壓的(de)(de)(de)相(xiang)(xiang)位(wei)角,使電(dian)(dian)(dian)(dian)(dian)機的(de)(de)(de)功率因(yin)數(shu)提(ti)高(gao),得到(dao)補償。

當電(dian)機在(zai)某一負載下運行時,其轉子電(dian)流為(wei)I2e、定子電(dian)流為(wei)I1e, 向(xiang)量(liang)圖(tu)如(ru)下所示。







從電(dian)(dian)機學我(wo)們知道,激磁(ci)(ci)電(dian)(dian)流(liu)Im由(you)(you)關系(xi)式Im=I1e-I2e,從向量(liang)圖可(ke)得出Im。當進(jin)相器的電(dian)(dian)勢疊(die)加在轉子(zi)回路后,轉子(zi)電(dian)(dian)流(liu)的相位變(bian)為圖中(zhong)的I2。由(you)(you)于(yu)負載不(bu)變(bian),激磁(ci)(ci)電(dian)(dian)流(liu)Im不(bu)變(bian)。此(ci)時的定子(zi)電(dian)(dian)流(liu)I1由(you)(you)關系(xi)式I1=Im+I2從向量(liang)圖可(ke)得出I1,如圖所示(shi)。從圖中(zhong)可(ke)以看(kan)出I1的功率因數角和幅值都比(bi)I1e小,說明電(dian)(dian)機的功率因數有(you)所提高,定子(zi)電(dian)(dian)流(liu)有(you)所下降(jiang)。

進(jin)相(xiang)器就是(shi)這(zhe)樣改變轉子(zi)電(dian)流與轉子(zi)電(dian)壓的(de)(de)相(xiang)位關(guan)系(xi),通(tong)過磁場進(jin)而改變電(dian)機(ji)定子(zi)電(dian)流與定子(zi)電(dian)壓的(de)(de)相(xiang)位關(guan)系(xi),減(jian)小功率(lv)因數角,終(zhong)使電(dian)機(ji)本身的(de)(de)功率(lv)因數得以提高,定子(zi)電(dian)流得以下(xia)降,達到對電(dian)機(ji)補償的(de)(de)目的(de)(de)。

當負載(zai)發生改變時,微處理器(qi)實時檢測電(dian)機(ji)參數的(de)變化,并根據負載(zai)的(de)變化,動態調整(zheng)附(fu)加在轉子(zi)上(shang)的(de)電(dian)勢幅(fu)值(zhi),以使電(dian)機(ji)的(de)功(gong)率因數始(shi)終保持在期望值(zhi)上(shang)。

四原理框圖






電(dian)容(rong)式補償的矢量分析:








電容補償(chang)(chang)和(he)進相器補償(chang)(chang)的原理圖分(fen)別(bie)如下:






圖中,將電(dian)(dian)(dian)(dian)機進行了(le)等(deng)效簡(jian)化,R1、X1為(wei)電(dian)(dian)(dian)(dian)機定子等(deng)效電(dian)(dian)(dian)(dian)路的(de)電(dian)(dian)(dian)(dian)阻和(he)電(dian)(dian)(dian)(dian)感,R2、X2為(wei)電(dian)(dian)(dian)(dian)機轉子等(deng)效電(dian)(dian)(dian)(dian)路的(de)電(dian)(dian)(dian)(dian)阻和(he)電(dian)(dian)(dian)(dian)感,C為(wei)就地補償的(de)電(dian)(dian)(dian)(dian)容,Uf為(wei)進相器的(de)等(deng)效電(dian)(dian)(dian)(dian)路,M為(wei)電(dian)(dian)(dian)(dian)機的(de)接線點。

從圖可以(yi)看出,靜止式進相(xiang)器和電容補償對電機(ji)的(de)作用點(dian)不同,電容是(shi)在電機(ji)的(de)前端(duan)(duan)定子側進行補償,其補償范(fan)圍(wei)是(shi)在補償點(dian)的(de)前端(duan)(duan);靜止式進相(xiang)器串聯在電機(ji)的(de)后端(duan)(duan),其補償范(fan)圍(wei)擴大到(dao)了電機(ji)。

五(wu)性能特點

1、可使電機的(de)功(gong)率因數提高到(dao)0.95以上(shang),無功(gong)功(gong)率降低(di)60%以上(shang)。

2、降(jiang)低定(ding)子電(dian)流10%-20%。

3、降低線損、銅損20%-30%。

4、電機(ji)溫升降低(di)5%。

5、過載能力(li)和效率大大提(ti)高,電機使用壽命延長。

6、具有故障(zhang)自(zi)動保(bao)護功能(neng),保(bao)障(zhang)設備長期安(an)全運行。

7、操作簡單(dan),安(an)裝調試和維修保養均不影(ying)響正(zheng)常生產,半年內(nei)可收回(hui)成本。

六使用條(tiao)件

1、安裝地點環境溫度≤40℃

2、安裝(zhuang)地點相對濕度(du)≤90%

3、 安裝(zhuang)地點無火災、爆炸危(wei)險品,無化學(xue)腐蝕及劇烈振動。

4、海拔高度≤1500M。

5、進相器柜體(ti)(ti)上方0.5米內(nei)應通風;如無地溝,須將(jiang)進相器柜體(ti)(ti)架空0.1米。

注:TP系列靜止式進相(xiang)器應滿足(zu)上(shang)方要(yao)求的(de)使(shi)用條件,襄陽拓邦電氣還可提供適用于高原地區(海拔超(chao)過1500米)的靜止式進相器(但用戶須事先特別申(shen)請)。

七技術參數


相 器 型 號

配 電 機 參 數

額定轉子電流(A

額定功率(KW

TP-400

400

95-800

TP-500

400-500

245-1000

TP-600

500-600

315-1250

TP-800

600-800

630-1600

TP-1000

800-1000

1000-2000

TP-1200

1000-1200

1600-2500

TP-1500

1200-1500

2000以上




八安裝(zhuang)尺寸

1、外型(xing)尺寸圖






2、安裝基礎圖







3、規格尺寸(cun)表(biao)



型號(hao)

外形尺寸(MM)

安裝尺寸(MM)

(W)

(D)

(H)

(E)

(F)

螺孔

TP400-600

1000

760

2000

780

620

14

TP800-1000

1100

800

2000

880

650

14

TP1200-1500

1200

900

2200

980

750

16



注:隨著產(chan)品不斷更新換代,外形(xing)及安裝尺(chi)寸會有所變化,請以具體的產(chan)品為準。

九安裝調試(shi)

(一(yi))安裝(zhuang)

1、將(jiang)進(jin)相(xiang)器(qi)搬到安裝位置(zhi),注意進(jin)相(xiang)器(qi)柜體底部應與地溝相(xiang)通或架空,首(shou)先是(shi)打開(kai)柜子的前后門(men),從上到下,逐(zhu)一地擰緊螺絲,防止在運輸過程中螺絲松動造成進(jin)相(xiang)器(qi)不能正常工作(zuo)。

2、準備好連接(jie)【主電(dian)機(ji)轉(zhuan)子(zi)至進相器(qi)接(jie)觸器(qi)KM13的(de)三根電(dian)纜】、【進相器(qi)接(jie)觸器(qi)KM11至主電(dian)機(ji)起動柜的(de)三根電(dian)纜】,其線徑應能(neng)承載主電(dian)機(ji)轉(zhuan)子(zi)額定(ding)電(dian)流,比好長度并壓好接(jie)頭。

3、進(jin)相器(qi)(qi)(qi)上(shang)的(de)(de)(de)電(dian)(dian)(dian)流表、功(gong)率因數表是直接從電(dian)(dian)(dian)機定(ding)子回路上(shang)的(de)(de)(de)電(dian)(dian)(dian)流互(hu)感(gan)(gan)器(qi)(qi)(qi)、電(dian)(dian)(dian)壓互(hu)感(gan)(gan)器(qi)(qi)(qi)取(qu)信號,要(yao)求(qiu)所用電(dian)(dian)(dian)流互(hu)感(gan)(gan)器(qi)(qi)(qi)副(fu)邊的(de)(de)(de)額定(ding)電(dian)(dian)(dian)流為(wei)5A、電(dian)(dian)(dian)壓互(hu)感(gan)(gan)器(qi)(qi)(qi)副(fu)邊的(de)(de)(de)額定(ding)電(dian)(dian)(dian)壓為(wei)100V,若用戶現用的(de)(de)(de)不滿足該(gai)要(yao)求(qiu),則須另(ling)行準備符合上(shang)述要(yao)求(qiu)的(de)(de)(de)互(hu)感(gan)(gan)器(qi)(qi)(qi)。(注:電(dian)(dian)(dian)壓互(hu)感(gan)(gan)器(qi)(qi)(qi)僅適用于高壓電(dian)(dian)(dian)機,對低壓電(dian)(dian)(dian)機,進(jin)相器(qi)(qi)(qi)電(dian)(dian)(dian)壓信號直接從定(ding)子回路取(qu))

4、新電機須帶上90%以上負載(zai)并正常(chang)運轉后(hou)才可調試(shi)進相器,用戶在通知我方調試(shi)前,應調試(shi)好電機、減速機、磨機等其(qi)它設備,使(shi)其(qi)帶上負載(zai)正常(chang)運轉,以免延誤(wu)進相器調試(shi)時間。

5、各聯鎖線(xian)意義如下:

(225、227)取自電機起動柜(ju)星點(dian)短接接觸器的(de)輔助(zhu)常開點(dian),只有在(zai)電機起動完畢后,進相器才可以(yi)進相。

(355、357)當(dang)開關(guan)柜主(zhu)開關(guan)是(shi)接觸器時(shi)與分(fen)閘(zha)按(an)鈕(niu)并聯;是(shi)斷路器時(shi)與分(fen)閘(zha)按(an)鈕(niu)串聯, 進相狀(zhuang)態下主(zhu)電機不(bu)能停機,只有先(xian)退相才能停主(zhu)機。

(359、361)串入(ru)開關柜合(he)閘(zha)回路。當KM11吸合(he)時,可以起動電(dian)機。

(363、369)從起(qi)動柜控制電(dian)源(yuan)引單(dan)相(xiang)380V,使KM11與(yu)起(qi)動柜控制回路(lu)同時得(de)電(dian)。

(30、32)串入主(zhu)電機電流計量(liang)回路;(40、42)并(bing)入主(zhu)電機電壓(ya)(ya)計量(liang)回路。(取A相電流則取B,C相電壓(ya)(ya),如此類推,電流和電壓(ya)(ya)不得取同(tong)相)。

(A、B、C、N)接三(san)相(xiang)四線電(dian)源,導線橫截(jie)面積(ji):TP600以下(xia)(xia)用4mm2;TP1000以下(xia)(xia)用6mm2;TP1500以下(xia)(xia)用10mm2。

6、控制器所有(you)指示燈的含義說明(ming)如下:

(1)主板(中間(jian)一塊)的指示燈(deng)(從(cong)上往(wang)下數)

●L1、L2、L3:電(dian)機(ji)(ji)(ji)轉(zhuan)子三相電(dian)流信號指(zhi)示(shi)(電(dian)機(ji)(ji)(ji)運轉(zhuan)時(shi)為循環(huan)顯示(shi)狀態(tai);自檢(jian)試驗時(shi)為隨機(ji)(ji)(ji)狀態(tai):或亮(liang)、或滅)

●L4:+5V電源指示(保(bao)持亮的狀態)

●L5:熱故(gu)障指示(有熱故(gu)障時L5滅)

●L6:缺相及自動故障(zhang)保護指示(有缺相故障(zhang)及其它故障(zhang)時L6燈滅)

●L7:+15V電源指示(保持(chi)亮的狀態)

●L8:-15V電源(yuan)指(zhi)示(保持亮的狀態)

(2)驅(qu)動板(ban)(兩(liang)邊(bian)兩(liang)塊)

●分別代表12個可控制硅的觸發(fa)信號(指(zhi)示燈(deng)均亮,并有規(gui)律的閃爍)

(二)試驗

1、檢查(cha)主電(dian)纜、聯鎖線(xian)、儀表(biao)線(xian)連接是否正確(que)。

2、檢查各器件螺(luo)絲是否緊固(gu)。

3、用萬用表測量(liang)可控硅極間電阻(zu):

●觸(chu)發極(ji)G與陰(yin)極(ji)K間電阻為幾十歐姆;

●觸發極(ji)G與陽極(ji)A間(jian)電阻大于幾(ji)十千(qian)歐;

●陰極K與陽(yang)極A間電阻大于幾十千(qian)歐(ou);

●陰極(ji)K與(yu)陽(yang)極(ji)A用萬用表200K檔測量,阻值應(ying)從小(xiao)變化到無限大。

4、合(he)上起動柜(ju)電源,進(jin)相器(qi)(qi)背面的接觸(chu)器(qi)(qi)KM11應吸合(he),短接225、227;合(he)上進(jin)相器(qi)(qi)電源,電源指(zhi)示燈(deng)(deng)亮(liang);控(kong)制器(qi)(qi)應有電,控(kong)制器(qi)(qi)上指(zhi)示燈(deng)(deng)亮(liang)。

5、控制器上撥碼開關(guan)打在ON(上方(fang))位置,中間主板L1、L2、L3循環亮或(huo)滅(mie),L4~L8全亮;兩邊兩塊驅動板指(zhi)示燈(deng)閃爍。

6、按綠色進相(xiang)按鈕,進相(xiang)器(qi)(qi)前面的接(jie)觸器(qi)(qi)KM13吸合,延時后,背面的接(jie)觸器(qi)(qi)KM11斷開,綠色進相(xiang)指示燈亮,風機運轉,風應向上吹,主變壓器(qi)(qi)副邊(bian)電流不超過(guo)30A,并且沒有大幅(fu)度變化。

7、按紅(hong)色(se)退(tui)相按鈕,進(jin)相器后(hou)(hou)面的接(jie)觸器KM11吸合,延時后(hou)(hou),前面的接(jie)觸器KM13斷開,綠色(se)進(jin)相指(zhi)(zhi)示燈滅,紅(hong)色(se)電(dian)源指(zhi)(zhi)示燈亮,進(jin)相器即退(tui)出進(jin)相狀態。

8、通電試驗結束,請務必斷開225、227。

(三(san))調試

1、運行前:控制器(qi)主板上撥碼(ma)開關應打在OFF(下方)位置。

2、起動主電(dian)機:打開進相器前柜(ju)門(men),合上空氣(qi)開關,進相器電(dian)源(yuan)接通,面板(ban)上的紅色電(dian)源(yuan)指示燈亮(liang),關閉柜(ju)門(men),等(deng)待(dai)主機起動。

3、進(jin)(jin)相:(1)電(dian)機正常(chang)運轉后,按(an)綠色(se)進(jin)(jin)相按(an)鈕(niu),進(jin)(jin)相器(qi)(qi)前面的接(jie)觸(chu)器(qi)(qi)KM13吸合,延時后,背面的接(jie)觸(chu)器(qi)(qi)KM11斷開,綠色(se)進(jin)(jin)相指示(shi)燈(deng)亮(liang),風機運轉,定子(zi)電(dian)流應(ying)下降(jiang),功率因數應(ying)上升。如(ru)果定子(zi)電(dian)流不下降(jiang)反而上升,調整同步變壓器(qi)(qi)上6V、6V0兩線的位置,再進(jin)(jin)相。

(2)測量主變壓(ya)器原、副邊電流,應(ying)無大幅度擺動(dong)。

(3)電(dian)機定子電(dian)流應平(ping)穩,無大幅度擺動。

(4)六個電抗(kang)器上端銅(tong)排(pai)的電流擺動幅度(du)應一致。

4、退(tui)相(xiang)(xiang):按(an)紅色(se)退(tui)相(xiang)(xiang)按(an)鈕,進(jin)相(xiang)(xiang)器后面(mian)的接(jie)觸器KM11吸合,延時后,前面(mian)的接(jie)觸器KM13斷開,綠色(se)進(jin)相(xiang)(xiang)指示燈滅(mie),紅色(se)電源指示燈亮,進(jin)相(xiang)(xiang)器即退(tui)出進(jin)相(xiang)(xiang)狀態。

5、停車(che):進相器退相后,按(an)下主機(ji)停車(che)按(an)鈕,電機(ji)即停車(che)。

(四)測量(liang)和觀察

1、測量可(ke)控硅、銅排、交流接觸器(qi)、電抗器(qi)、主(zhu)變壓器(qi)、控制板溫度。

2、測量可控硅觸發電(dian)壓(ya);主變壓(ya)器一(yi)次(ci)、二次(ci)電(dian)流;電(dian)抗器輸入電(dian)流。

3、觀察風機運(yun)行情(qing)況。

4、觀察(cha)整體運行(xing)情況,有無異常響(xiang)聲或銅排有無大(da)的抖動(dong)現(xian)象等(deng)。

十(shi)使用維護

為(wei)確保TP系列靜止式進相器長期安(an)全(quan)、可(ke)靠地運行(xing),請操作人員特別(bie)注(zhu)意(yi)以(yi)下(xia)事項:

1、嚴禁在進相(xiang)器運行期間,切斷進相(xiang)器外部電源。

2、定(ding)期檢(jian)查冷卻風機(ji)(ji)運轉(zhuan)狀(zhuang)況,冷卻風機(ji)(ji)停轉(zhuan)使可控硅(gui)散熱(re)能力(li)下(xia)降(jiang),可能燒壞可控硅(gui)。

3、定期(qi)檢測主變(bian)壓器原、副邊運行電流(liu)。

4、定期(qi)檢(jian)測(ce)可控硅、聯接銅排、交流接觸器(qi)、電(dian)抗(kang)器(qi)、主(zhu)變壓器(qi)、控制(zhi)板的溫度。

5、定期檢(jian)(jian)修主(zhu)回路接(jie)(jie)觸器(qi)的(de)觸頭(tou)。真空(kong)接(jie)(jie)觸器(qi)定期檢(jian)(jian)測絕(jue)緣(yuan)電(dian)(dian)阻(zu),用(yong)5KV或2.5KV搖表檢(jian)(jian)查,當開關管絕(jue)緣(yuan)電(dian)(dian)阻(zu)小于100兆歐時,應加強監視,小于20兆歐時應立即更換新管,以延長接(jie)(jie)觸器(qi)的(de)使用(yong)壽(shou)命(ming),保(bao)障進相(xiang)器(qi)及(ji)電(dian)(dian)機安全(quan)運行。

6、當進(jin)相(xiang)器停用(yong)一段時間又重(zhong)新啟用(yong)時, 次(ci)進(jin)相(xiang)前應觀察柜內控制單元上各指示燈(deng)是否(fou)正常。電(dian)機起(qi)動(dong)并正常運轉后,各指示燈(deng)顯示如(ru)下:

·主板(中間一塊):除L1,L2,L3周(zhou)期性(xing)循環(huan)顯(xian)示外(wai)(注意(yi):此指電機(ji)在運轉時(shi)的狀態,若電機(ji)未(wei)轉,該三燈為隨(sui)機(ji)狀態),其它各燈均(jun)亮(liang)。

·驅動扳(ban)(兩(liang)(liang)邊的兩(liang)(liang)塊):其上面各指示燈均亮(liang)并有(you)輕微閃(shan)爍。

7、當電機定子電流出現異常大幅(fu)擺動時,應立即退相,查(cha)出原因并(bing)檢修(xiu)后投入(ru)使用(yong)。

8、定期(qi)打掃柜內(nei)衛生(sheng)。

十(shi)一故障處理



主電機不能起(qi)動

端子363、369無380V 電源

檢查起動(dong)柜控制(zhi)電源

 

接觸器KM11不吸合

檢查KM11線包及其控制回路

 

接觸器KM11吸合,但其輔助觸點未閉合

檢修其(qi)輔助觸點(dian)

 

端子359、361串入合閘回路的線未接通

檢(jian)查該回路

不能(neng)投(tou)入(ru)進相

空氣開關QF1、QF2、QF3沒合上

合上(shang)空氣開(kai)關

 

按鈕STP、ST接觸不良

 

 

中間繼電器KA11觸點接觸不良

 

 

主電機起動柜內星點接觸器常開輔助觸點不能閉合(225、227未接通)

檢修該接觸(chu)器(qi)輔(fu)助觸(chu)點及連線

 

KM13不能(neng)吸(xi)合

檢查KM13線包及其控制回路

 

固態繼電器FV損壞或者不導通

控制器主控制板L6燈滅

檢查主控板7腳對11、12、13腳有無+、-3伏左右電壓,否則更換電流傳感器

 

 

檢查固態繼電器FV

FV的3、4腳有直流(liu)15V電壓,而(er)323、325不通(tong),須更(geng)換(huan)該(gai)繼(ji)電器(qi)

進相后(hou)主電機停機

接入開關柜的KM11、KM13的輔助觸點359、361接觸不好

維修該觸點

 

進相(xiang)器投入進相(xiang)瞬間外部空(kong)氣開(kai)關跳閘(zha)

更換大規格的(de)空氣開關

進相后無效果

接入主控板(ban)的(de)電(dian)流傳感器信號(hao)線錯誤

電流傳感器從左到右TA1、TA2、TA3的信號線應分別對應與主控板的13、12、11腳

 

主(zhu)控板的撥碼(ma)開關在(zai)自檢位(wei)

撥碼開關撥至工作位

 

KM13吸合后KM11未釋放(時(shi)間(jian)繼電器KT11壞)

更換KT11時間繼電器

 

KM15沒(mei)有吸(xi)合

KM11的輔助(zhu)觸點301、305接觸不良

維(wei)修該(gai)觸點

 

 

KM15線(xian)圈(quan)故障

更換KM15線圈

 

KM15主觸點(dian)接觸不良

更換KM15

 

主變(bian)壓(ya)器原邊(bian)開路

更換(huan)主變壓器

進相后(hou)主(zhu)電機電流不減反增

同步電源(yuan)相序(xu)錯誤(wu)

調換進相器內小變壓器TC上輸出6V、6V0電壓的兩線位置

 

電機轉速下(xia)降(缺相),自動(dong)退相

KM13主觸點接觸不(bu)良

維修該觸點

 

 

電(dian)機(ji)轉子線松動,進相時的電(dian)流沖擊導致(zhi)缺相

檢查電機轉(zhuan)子線(xian)

進相后主(zhu)電機電流(liu)擺(bai)動大

可(ke)控硅擊穿

測(ce)量可控硅(gui)極間電阻(zu)(詳細方法見調試部(bu)分(fen))

 

觸(chu)發板(ban)損壞

測量可控硅控制極與陰極之間應有0.2V以上的直流電壓信號,否則應檢查觸發板

 

主板的撥(bo)碼(ma)開關在自檢位

撥碼開關(guan)撥至工作位

 

電機轉子線(xian)松動(dong)

檢查(cha)電機轉子線

 

KM13采用節能型線圈時,線圈故障導致KM13進行瞬間來回釋放、吸合,導致主回路接觸不良

維修或更換KM13線圈





注意:進相器檢修不得(de)在進相(xiang)狀態(tai)下進行,發現問(wen)題應立即(ji)退相(xiang)。

十二控制板檢修(xiu)



現象

原(yuan)因

對策

L1L2L3不循環閃爍,L6滅,其它各燈正常

轉(zhuan)子缺相(xiang)

檢查接觸器KM2主觸頭是否損壞,若損壞,則維修觸頭或更換接觸器

電流傳(chuan)感器器損壞

檢查電流傳感器是否有±2V以上的輸出信號,否則更換傳感器

主(zhu)控(kong)板元器(qi)件損壞(huai)

依次更換IC210IC211

L1L2L3不周期性閃爍,其它各燈正常

主(zhu)控板元器件損壞

依次更換IC210IC211IC205IC207

L6滅,其它各燈正常

主控板元器件損壞(huai)

依次更換IC207IC209

L5滅,其它各燈正常

散熱器溫(wen)度檢測(ce)回(hui)路故障

檢查(cha)溫度(du)開關(guan)及其連線(xian)

L4L7L8全部或部分滅

電源故障

1、檢查變壓器及控制板是否有±18V電源

2、更換相應的780578157915

F1-L1L6 F2-L1L6部分指示燈亮,主板各燈正常

觸(chu)發板元(yuan)器件(jian)損壞

1、有一片ULN2004損壞,更換之

2、脈沖變壓器接觸不良,作相應處理

F1-L1L6 F2-L1L6指示燈全滅,主板各燈正常

觸發板(ban)元器(qi)件損壞

1、兩片ULN2004損壞,更換之

2、更換555芯片

觸發板無電(dian)源

1、檢查主板7815是否有虛焊

2、檢查觸發板19腳與主板6腳連接是否正常





十三注意事項(xiang)

1、進相器檢修應在退相狀(zhuang)態下進行,發(fa)現問題應立(li)即退相。

2、嚴(yan)禁隨意帶電插拔控制板,檢修控制板時(shi),一定要把空開QF3打下來。

3、更換可(ke)(ke)(ke)控硅(gui)時(shi)應注意陰、陽極的(de)(de)方(fang)向,并壓(ya)緊(jin)散熱器(壓(ya)力不要過大),裝上后擰緊(jin)所有螺絲(si),之(zhi)后再檢測可(ke)(ke)(ke)控硅(gui)各極間的(de)(de)電阻(zu)情況。若一只(zhi)可(ke)(ke)(ke)控硅(gui)擊穿在(zai)柜體上直接檢測,同(tong)一相的(de)(de)四個可(ke)(ke)(ke)控硅(gui)均顯示擊穿,此時(shi)應把該組可(ke)(ke)(ke)控硅(gui)間的(de)(de)聯接銅排(pai)拆掉再測 。

十四(si)訂貨須(xu)知(zhi)

1、提(ti)供電(dian)機型號、額(e)定功率、定子(zi)電(dian)壓(ya)、定子(zi)電(dian)流(liu)、轉(zhuan)子(zi)電(dian)壓(ya)、轉(zhuan)子(zi)電(dian)流(liu)、額(e)定功率因數。

2、提(ti)供電機拖動負(fu)載的特征(zheng)及負(fu)載率。

預知TP系列無環流靜止式進相器的更多信(xin)息,請(qing)撥打襄陽拓邦電(dian)氣(qi)官網電(dian)話: 鄭(zheng)經理17771133316或咨(zi)詢網站(zhan)客(ke)服(fu)!!

在線留言

LEAVE A MESSAGE