欧美最猛性XXXXX69交_亚洲精品无码永久电影在线_欧美黑人粗大xxxxbbbb_中文字幕日韩精品有码视频

榆林產品中心
榆林產品中心

榆林產品中心

product

榆林TP系列靜止式進相器

一(yi)概(gai)述TP系列(lie)無環流靜止式進相器(qi)是襄陽拓邦電氣自選研制開發的新(xin)一(yi)代高新(xin)技術產品,是一(yi)種專為(wei)大中型繞線(xian)式異……

相關內容
在線留言
詳情內容
content details

TP系列無環流靜止式進相器是(shi)襄陽拓(tuo)邦電(dian)(dian)(dian)氣自(zi)選研制開發的(de)(de)新一(yi)代高(gao)新技術產(chan)品,是(shi)一(yi)種(zhong)(zhong)專(zhuan)為(wei)大中型繞線式(shi)異(yi)步電(dian)(dian)(dian)動機(ji)設計制作的(de)(de)就(jiu)地無功(gong)功(gong)率(lv)補償裝置。它串接于電(dian)(dian)(dian)機(ji)轉(zhuan)子回路,改(gai)變(bian)轉(zhuan)子電(dian)(dian)(dian)流(liu)與(yu)(yu)轉(zhuan)子電(dian)(dian)(dian)壓的(de)(de)相(xiang)位關(guan)系(xi),通過(guo)磁場進而改(gai)變(bian)電(dian)(dian)(dian)機(ji)定(ding)(ding)子電(dian)(dian)(dian)流(liu)與(yu)(yu)電(dian)(dian)(dian)壓的(de)(de)相(xiang)位關(guan)系(xi),達到提高(gao)電(dian)(dian)(dian)機(ji)自(zi)身功(gong)率(lv)因數、降低電(dian)(dian)(dian)機(ji)定(ding)(ding)子電(dian)(dian)(dian)流(liu)和溫升(sheng)的(de)(de)目(mu)的(de)(de)。這種(zhong)(zhong)方(fang)式(shi)從(cong)根本上(shang)改(gai)善了(le)電(dian)(dian)(dian)機(ji)的(de)(de)運行狀(zhuang)況,顯著降低電(dian)(dian)(dian)機(ji)及電(dian)(dian)(dian)網的(de)(de)無功(gong)損(sun)耗,對節(jie)能(neng)降耗、降低單位產(chan)品成本,提高(gao)企業的(de)(de)經濟效益具有重要(yao)的(de)(de)意(yi)義。


TP系列無(wu)(wu)環流靜止式進(jin)相(xiang)器對(dui)無(wu)(wu)功(gong)功(gong)率的(de)(de)補(bu)償(chang)(chang)與電機(ji)定子側并聯(lian)電容(rong)器的(de)(de)補(bu)償(chang)(chang)有著本質的(de)(de)區別。電容(rong)補(bu)償(chang)(chang)只是在電機(ji)之(zhi)外的(de)(de)電網(wang)上(shang)對(dui)無(wu)(wu)功(gong)進(jin)行補(bu)償(chang)(chang),減少(shao)電網(wang)的(de)(de)無(wu)(wu)功(gong)輸(shu)入,電網(wang)的(de)(de)功(gong)率因(yin)數得(de)到提高,但是電機(ji)的(de)(de)無(wu)(wu)功(gong)消耗并沒有減少(shao),無(wu)(wu)法改善電機(ji)本身(shen)的(de)(de)運行狀況(kuang);而TP系列靜止式進相器是串接在電機(ji)(ji)轉(zhuan)子(zi)(zi)回路中,不僅可顯著(zhu)提(ti)高(gao)功率因數,使(shi)電機(ji)(ji)定子(zi)(zi)電流(liu)大幅度降低,而且電機(ji)(ji)溫升明顯降低,電機(ji)(ji)的效率和過載(zai)能力顯著(zhu)提(ti)高(gao)。

TP系(xi)列(lie)靜止(zhi)式(shi)(shi)進(jin)(jin)(jin)相(xiang)(xiang)(xiang)器與自(zi)激(旋(xuan)轉)式(shi)(shi)進(jin)(jin)(jin)相(xiang)(xiang)(xiang)機(ji)(ji)(ji)也不同。TP系(xi)列(lie)靜止(zhi)式(shi)(shi)進(jin)(jin)(jin)相(xiang)(xiang)(xiang)器采(cai)用(yong)了 的交-交變頻(pin)技(ji)術和微(wei)機(ji)(ji)(ji)、可控(kong)硅控(kong)制技(ji)術,可自(zi)動跟蹤電機(ji)(ji)(ji)運行狀態(tai)的變化并(bing)自(zi)動調整(zheng)相(xiang)(xiang)(xiang)關參數以達到(dao)(dao)佳的補償效果,這(zhe)是自(zi)激式(shi)(shi)進(jin)(jin)(jin)相(xiang)(xiang)(xiang)機(ji)(ji)(ji)無法做到(dao)(dao)的。而且,TP系(xi)列(lie)靜止(zhi)式(shi)(shi)進(jin)(jin)(jin)相(xiang)(xiang)(xiang)器從根本上(shang)克服了自(zi)激式(shi)(shi)進(jin)(jin)(jin)相(xiang)(xiang)(xiang)機(ji)(ji)(ji)“整(zheng)流子”結(jie)構特別怕塵埃、壽命(ming)短、維修頻(pin)繁的缺(que)點;具有參數調節容易、主回路無轉動部件、不怕灰(hui)塵、可靠性高、使(shi)用(yong)壽命(ming)長、維護方便,是理(li)想的取代自(zi)激式(shi)(shi)進(jin)(jin)(jin)相(xiang)(xiang)(xiang)機(ji)(ji)(ji)的新型高科技(ji)產品。

TP系列(lie)靜止式進相器可廣泛用于水泥、化工、礦山(shan)、冶金、鋼鐵、造紙、制藥(yao)等行業的大(da)中型高低壓繞線式異步(bu)電機。


二型號命(ming)名

TP系列靜止式進相器型號命名方(fang)法如(ru)下:





型號(hao):TP-800,表示適用于(yu)額定轉子電(dian)流不超過(guo)800A的電(dian)機的靜止式進相器。


三工(gong)作原理(li)

當電(dian)機運行(xing)進(jin)相(xiang)(xiang)(xiang)時,進(jin)相(xiang)(xiang)(xiang)器(qi)通(tong)(tong)過轉(zhuan)子電(dian)流(liu)傳感(gan)器(qi)采集到的(de)(de)轉(zhuan)子電(dian)流(liu)信號及工(gong)頻(pin)電(dian)壓(ya)提供的(de)(de)同步信號經微(wei)處理(li)器(qi)CPU進(jin)行(xing)數據和(he)相(xiang)(xiang)(xiang)位處理(li),控制可(ke)控硅的(de)(de)觸發信號,調整由12只晶閘管組成的(de)(de)交(jiao)—交(jiao)變(bian)頻(pin)裝置,將降壓(ya)后的(de)(de)工(gong)頻(pin)電(dian)源(yuan)變(bian)為和(he)轉(zhuan)子電(dian)流(liu)同頻(pin)率,相(xiang)(xiang)(xiang)位滯后90°的(de)(de)附(fu)加(jia)電(dian)勢加(jia)在電(dian)機轉(zhuan)子回路中。轉(zhuan)子的(de)(de)電(dian)流(liu)和(he)電(dian)壓(ya)相(xiang)(xiang)(xiang)位因(yin)此改(gai)變(bian),通(tong)(tong)過磁場進(jin)而改(gai)變(bian)電(dian)機定子電(dian)流(liu)與定子電(dian)壓(ya)的(de)(de)相(xiang)(xiang)(xiang)位角,使電(dian)機的(de)(de)功率因(yin)數提高,得到補(bu)償。

當電機在(zai)某(mou)一(yi)負(fu)載下(xia)運行(xing)時,其轉子電流為I2e、定子電流為I1e, 向(xiang)量圖如下(xia)所示。







從(cong)(cong)電機(ji)學我們知道,激磁(ci)(ci)電流(liu)Im由關(guan)系式Im=I1e-I2e,從(cong)(cong)向(xiang)(xiang)量圖(tu)可(ke)得(de)出Im。當進相(xiang)器的電勢疊加(jia)在轉(zhuan)子回(hui)路后,轉(zhuan)子電流(liu)的相(xiang)位變(bian)(bian)為圖(tu)中的I2。由于(yu)負載(zai)不變(bian)(bian),激磁(ci)(ci)電流(liu)Im不變(bian)(bian)。此時的定(ding)子電流(liu)I1由關(guan)系式I1=Im+I2從(cong)(cong)向(xiang)(xiang)量圖(tu)可(ke)得(de)出I1,如圖(tu)所(suo)示。從(cong)(cong)圖(tu)中可(ke)以(yi)看出I1的功(gong)率(lv)因數角和幅值都比I1e小,說明電機(ji)的功(gong)率(lv)因數有(you)(you)所(suo)提(ti)高,定(ding)子電流(liu)有(you)(you)所(suo)下降。

進相(xiang)器就是(shi)這(zhe)樣改(gai)變轉子(zi)電(dian)(dian)流與轉子(zi)電(dian)(dian)壓(ya)(ya)的相(xiang)位關(guan)系(xi),通過磁場進而改(gai)變電(dian)(dian)機(ji)定子(zi)電(dian)(dian)流與定子(zi)電(dian)(dian)壓(ya)(ya)的相(xiang)位關(guan)系(xi),減小功率因數角(jiao),終使電(dian)(dian)機(ji)本身的功率因數得(de)以提高,定子(zi)電(dian)(dian)流得(de)以下降,達(da)到對電(dian)(dian)機(ji)補償(chang)的目的。

當負載(zai)發生改變(bian)時,微處理(li)器實時檢測(ce)電(dian)機參數的(de)變(bian)化,并(bing)根據(ju)負載(zai)的(de)變(bian)化,動(dong)態調整附加在轉子上的(de)電(dian)勢(shi)幅值,以使(shi)電(dian)機的(de)功率(lv)因數始終保(bao)持在期望值上。

四原(yuan)理框圖






電容式補(bu)償的矢量分析(xi):








電容補償和進相器補償的(de)原理(li)圖(tu)分別(bie)如下:






圖中,將電(dian)機(ji)進行(xing)了等(deng)效(xiao)簡化(hua),R1、X1為電(dian)機(ji)定子等(deng)效(xiao)電(dian)路的電(dian)阻(zu)和(he)電(dian)感(gan)(gan),R2、X2為電(dian)機(ji)轉子等(deng)效(xiao)電(dian)路的電(dian)阻(zu)和(he)電(dian)感(gan)(gan),C為就地補償的電(dian)容(rong),Uf為進相(xiang)器的等(deng)效(xiao)電(dian)路,M為電(dian)機(ji)的接線點。

從圖可以看出,靜(jing)止式(shi)進(jin)(jin)(jin)相器和電容(rong)補償(chang)對(dui)電機(ji)(ji)的作用點(dian)(dian)不(bu)同(tong),電容(rong)是在(zai)(zai)電機(ji)(ji)的前端(duan)定子側進(jin)(jin)(jin)行補償(chang),其(qi)補償(chang)范(fan)圍是在(zai)(zai)補償(chang)點(dian)(dian)的前端(duan);靜(jing)止式(shi)進(jin)(jin)(jin)相器串聯在(zai)(zai)電機(ji)(ji)的后端(duan),其(qi)補償(chang)范(fan)圍擴大到了(le)電機(ji)(ji)。

五性能(neng)特點(dian)

1、可使電機的功率因數提高到0.95以(yi)上,無(wu)功功率降低60%以(yi)上。

2、降(jiang)低定子電流10%-20%。

3、降低線損(sun)、銅損(sun)20%-30%。

4、電機(ji)溫升降(jiang)低(di)5%。

5、過載(zai)能力和效率大大提高,電機使用(yong)壽命延長。

6、具(ju)有故障自動保護功能,保障設備(bei)長期安全運行。

7、操(cao)作簡單,安(an)裝調試和(he)維修保養均不影(ying)響正常生產,半(ban)年(nian)內(nei)可收(shou)回成(cheng)本。

六使用條(tiao)件

1、安裝地點環境溫度≤40℃

2、安裝地點相(xiang)對濕(shi)度(du)≤90%

3、 安裝地(di)點無火災(zai)、爆炸危(wei)險品,無化(hua)學腐蝕及劇烈振(zhen)動。

4、海拔高度≤1500M。

5、進相器柜(ju)體上(shang)方0.5米(mi)內應通風(feng);如無地(di)溝(gou),須將(jiang)進相器柜(ju)體架空0.1米(mi)。

注:TP系列靜止式進相器應滿(man)足(zu)上方(fang)要求(qiu)的使用條件,襄陽拓邦電氣還可提供(gong)適用(yong)于高原地區(海拔超過1500米)的(de)靜止式進相器(但用(yong)戶須(xu)事先特別(bie)申(shen)請)。

七技術參(can)數(shu)


相 器 型 號

配 電 機 參 數

額定轉子電流(A

額定功率(KW

TP-400

400

95-800

TP-500

400-500

245-1000

TP-600

500-600

315-1250

TP-800

600-800

630-1600

TP-1000

800-1000

1000-2000

TP-1200

1000-1200

1600-2500

TP-1500

1200-1500

2000以上




八(ba)安裝尺寸

1、外型(xing)尺寸圖






2、安裝基礎(chu)圖(tu)







3、規格尺寸表



型號

外形尺寸(MM)

安裝尺寸(MM)

(W)

(D)

(H)

(E)

(F)

螺孔

TP400-600

1000

760

2000

780

620

14

TP800-1000

1100

800

2000

880

650

14

TP1200-1500

1200

900

2200

980

750

16



注(zhu):隨著產品不斷更新換(huan)代,外形及安裝尺寸會(hui)有所變化,請以具體的產品為準。

九安裝調試

(一)安裝(zhuang)

1、將進相(xiang)器搬到安裝位置,注意進相(xiang)器柜(ju)體(ti)底部(bu)應(ying)與地溝相(xiang)通或架空(kong),首先是(shi)打開柜(ju)子的前后門,從上到下(xia),逐(zhu)一地擰緊螺絲,防止在(zai)運輸(shu)過程(cheng)中螺絲松動造成進相(xiang)器不能正(zheng)常工作。

2、準備好連(lian)接【主電(dian)機轉子至進(jin)相器接觸器KM13的三根電(dian)纜】、【進(jin)相器接觸器KM11至主電(dian)機起動柜(ju)的三根電(dian)纜】,其線徑(jing)應(ying)能承載主電(dian)機轉子額定電(dian)流(liu),比好長度并壓(ya)好接頭。

3、進(jin)相器(qi)(qi)上(shang)的電(dian)(dian)(dian)(dian)流表、功(gong)率因數表是直接(jie)從(cong)電(dian)(dian)(dian)(dian)機定(ding)子(zi)回路(lu)上(shang)的電(dian)(dian)(dian)(dian)流互(hu)(hu)(hu)感(gan)器(qi)(qi)、電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)互(hu)(hu)(hu)感(gan)器(qi)(qi)取信(xin)號,要求(qiu)所(suo)用電(dian)(dian)(dian)(dian)流互(hu)(hu)(hu)感(gan)器(qi)(qi)副邊的額定(ding)電(dian)(dian)(dian)(dian)流為5A、電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)互(hu)(hu)(hu)感(gan)器(qi)(qi)副邊的額定(ding)電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)為100V,若(ruo)用戶現用的不(bu)滿足該要求(qiu),則須另(ling)行準備符合上(shang)述要求(qiu)的互(hu)(hu)(hu)感(gan)器(qi)(qi)。(注(zhu):電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)互(hu)(hu)(hu)感(gan)器(qi)(qi)僅(jin)適用于高壓(ya)(ya)(ya)(ya)電(dian)(dian)(dian)(dian)機,對低(di)壓(ya)(ya)(ya)(ya)電(dian)(dian)(dian)(dian)機,進(jin)相器(qi)(qi)電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)信(xin)號直接(jie)從(cong)定(ding)子(zi)回路(lu)取)

4、新電機(ji)須(xu)帶上90%以(yi)上負載(zai)并正常(chang)運轉后才可調(diao)(diao)試進(jin)相器,用戶在(zai)通知(zhi)我方調(diao)(diao)試前,應調(diao)(diao)試好電機(ji)、減速機(ji)、磨機(ji)等其它設(she)備,使其帶上負載(zai)正常(chang)運轉,以(yi)免延誤進(jin)相器調(diao)(diao)試時間。

5、各聯鎖線(xian)意義如下:

(225、227)取自電機起動(dong)柜星點短接(jie)接(jie)觸器(qi)的輔(fu)助常開點,只有在(zai)電機起動(dong)完畢后,進相器(qi)才可(ke)以進相。

(355、357)當(dang)開(kai)關柜主(zhu)開(kai)關是接觸器(qi)時(shi)與分(fen)閘(zha)按鈕并(bing)聯(lian);是斷路(lu)器(qi)時(shi)與分(fen)閘(zha)按鈕串(chuan)聯(lian), 進相狀態下主(zhu)電(dian)機不能停機,只有先(xian)退相才(cai)能停主(zhu)機。

(359、361)串入開(kai)關柜(ju)合(he)閘回路。當KM11吸合(he)時,可以(yi)起動電機(ji)。

(363、369)從起(qi)(qi)動(dong)柜控制電(dian)源引(yin)單相380V,使KM11與起(qi)(qi)動(dong)柜控制回路同(tong)時得電(dian)。

(30、32)串入主電機電流計量回路;(40、42)并入主電機電壓(ya)(ya)(ya)計量回路。(取A相(xiang)電流則取B,C相(xiang)電壓(ya)(ya)(ya),如此類推(tui),電流和電壓(ya)(ya)(ya)不得取同相(xiang))。

(A、B、C、N)接(jie)三相四(si)線電源(yuan),導(dao)線橫(heng)截面積:TP600以(yi)下(xia)用(yong)4mm2;TP1000以(yi)下(xia)用(yong)6mm2;TP1500以(yi)下(xia)用(yong)10mm2。

6、控(kong)制器所有指(zhi)示燈的含(han)義(yi)說明(ming)如(ru)下:

(1)主板(ban)(中間一塊)的指示燈(從上往下數)

●L1、L2、L3:電(dian)機轉(zhuan)子三相電(dian)流信號指(zhi)示(電(dian)機運轉(zhuan)時為循環顯示狀(zhuang)態;自檢試驗(yan)時為隨(sui)機狀(zhuang)態:或亮、或滅)

●L4:+5V電源指(zhi)示(保(bao)持亮(liang)的狀態)

●L5:熱(re)故(gu)障(zhang)指(zhi)示(有熱(re)故(gu)障(zhang)時(shi)L5滅)

●L6:缺相及自(zi)動(dong)故障(zhang)(zhang)保護指示(有缺相故障(zhang)(zhang)及其(qi)它故障(zhang)(zhang)時L6燈滅)

●L7:+15V電(dian)源指(zhi)示(shi)(保持亮的狀態)

●L8:-15V電源指示(保持亮(liang)的狀(zhuang)態)

(2)驅(qu)動板(ban)(兩邊兩塊)

●分別(bie)代表12個可控制硅(gui)的觸發信號(指示燈均(jun)亮(liang),并(bing)有規律(lv)的閃爍(shuo))

(二(er))試(shi)驗

1、檢查主電纜、聯鎖線、儀表線連接是否正確(que)。

2、檢查各器(qi)件(jian)螺絲是否緊固。

3、用萬用表測量(liang)可控硅極間電阻:

●觸發極(ji)G與(yu)陰極(ji)K間電阻為幾十歐姆;

●觸發極G與(yu)陽(yang)極A間(jian)電(dian)阻大于幾十千歐;

●陰極K與(yu)陽(yang)極A間電阻(zu)大于幾十(shi)千歐;

●陰極K與陽極A用(yong)(yong)萬用(yong)(yong)表200K檔測量,阻值應從小變化到無(wu)限(xian)大。

4、合(he)上(shang)起動柜(ju)電(dian)源,進相(xiang)器背面(mian)的接觸(chu)器KM11應吸合(he),短接225、227;合(he)上(shang)進相(xiang)器電(dian)源,電(dian)源指示燈亮;控制器應有(you)電(dian),控制器上(shang)指示燈亮。

5、控制(zhi)器(qi)上撥碼開關打在ON(上方)位置,中間主板L1、L2、L3循(xun)環亮或(huo)滅(mie),L4~L8全亮;兩邊兩塊驅(qu)動板指示燈閃爍。

6、按綠色進(jin)相(xiang)按鈕,進(jin)相(xiang)器前面(mian)的接(jie)觸(chu)器KM13吸合(he),延時(shi)后,背面(mian)的接(jie)觸(chu)器KM11斷(duan)開,綠色進(jin)相(xiang)指示(shi)燈(deng)亮,風機運轉,風應向上吹(chui),主(zhu)變壓器副(fu)邊電流不超過30A,并且(qie)沒(mei)有大幅度(du)變化。

7、按紅色(se)退(tui)相按鈕,進(jin)(jin)(jin)(jin)相器(qi)后(hou)面(mian)的接觸(chu)器(qi)KM11吸(xi)合,延時后(hou),前面(mian)的接觸(chu)器(qi)KM13斷開,綠色(se)進(jin)(jin)(jin)(jin)相指示燈滅(mie),紅色(se)電源(yuan)指示燈亮,進(jin)(jin)(jin)(jin)相器(qi)即退(tui)出進(jin)(jin)(jin)(jin)相狀態。

8、通電試驗結束,請務(wu)必(bi)斷開225、227。

(三)調試

1、運(yun)行前:控(kong)制(zhi)器主板上撥碼開(kai)關應(ying)打在OFF(下方)位置。

2、起(qi)動(dong)主電(dian)機:打開進相器前柜(ju)門,合上(shang)空氣開關,進相器電(dian)源(yuan)接通,面板上(shang)的紅色電(dian)源(yuan)指示燈亮(liang),關閉(bi)柜(ju)門,等待主機起(qi)動(dong)。

3、進相(xiang):(1)電機正常運轉后,按(an)(an)綠色進相(xiang)按(an)(an)鈕,進相(xiang)器前面的(de)接(jie)觸(chu)器KM13吸合(he),延(yan)時后,背面的(de)接(jie)觸(chu)器KM11斷開,綠色進相(xiang)指示(shi)燈亮(liang),風機運轉,定(ding)子(zi)電流(liu)應下降,功(gong)率因數應上(shang)升。如(ru)果定(ding)子(zi)電流(liu)不下降反(fan)而上(shang)升,調整同步變壓器上(shang)6V、6V0兩線的(de)位(wei)置,再進相(xiang)。

(2)測量(liang)主變壓器原(yuan)、副邊電流(liu),應無(wu)大幅(fu)度(du)擺動(dong)。

(3)電機定子電流應平穩,無(wu)大幅度(du)擺動。

(4)六(liu)個電抗器上端銅(tong)排的電流(liu)擺動幅度應一致。

4、退相:按(an)紅色退相按(an)鈕,進(jin)相器后面的接觸(chu)器KM11吸合,延時后,前面的接觸(chu)器KM13斷開(kai),綠(lv)色進(jin)相指示燈滅,紅色電源(yuan)指示燈亮,進(jin)相器即(ji)退出進(jin)相狀態。

5、停車(che):進相器退相后,按下主機(ji)停車(che)按鈕,電機(ji)即停車(che)。

(四)測量(liang)和觀察

1、測量可控硅、銅排、交流接觸器、電抗器、主變(bian)壓器、控制板(ban)溫度。

2、測量可控硅(gui)觸(chu)發(fa)電(dian)壓;主變壓器一次、二次電(dian)流(liu);電(dian)抗(kang)器輸入電(dian)流(liu)。

3、觀(guan)察(cha)風機運行情(qing)況。

4、觀察整(zheng)體運行情況,有無(wu)異常響聲(sheng)或銅排有無(wu)大(da)的(de)抖動(dong)現象等。

十使用維護

為確保TP系列靜止式進相器長期安全(quan)、可靠(kao)地運行,請操(cao)作人員特別注意以下事項:

1、嚴禁在進相(xiang)器運行期間,切斷進相(xiang)器外(wai)部電源。

2、定期檢查(cha)冷(leng)卻風機(ji)運轉(zhuan)狀(zhuang)況(kuang),冷(leng)卻風機(ji)停(ting)轉(zhuan)使可(ke)(ke)控硅散熱(re)能力下降,可(ke)(ke)能燒壞可(ke)(ke)控硅。

3、定期檢測主(zhu)變壓器原、副邊運行(xing)電(dian)流。

4、定期檢測可控硅、聯接(jie)銅排、交流接(jie)觸器(qi)、電抗器(qi)、主(zhu)變(bian)壓器(qi)、控制板(ban)的溫度。

5、定期檢修主回路接觸器(qi)的觸頭。真空(kong)接觸器(qi)定期檢測絕緣(yuan)電(dian)阻(zu)(zu),用(yong)5KV或2.5KV搖表檢查,當開關(guan)管(guan)絕緣(yuan)電(dian)阻(zu)(zu)小于(yu)100兆歐(ou)時,應加強監視,小于(yu)20兆歐(ou)時應立即更換新(xin)管(guan),以(yi)延長(chang)接觸器(qi)的使(shi)用(yong)壽命,保(bao)障進(jin)相器(qi)及電(dian)機安(an)全運(yun)行(xing)。

6、當進相器停用一(yi)段時間又重新啟用時, 次進相前(qian)應觀察(cha)柜內控制單元上各指示(shi)燈(deng)(deng)是否(fou)正常。電(dian)機起動并正常運轉后,各指示(shi)燈(deng)(deng)顯示(shi)如下:

·主板(中(zhong)間一塊):除L1,L2,L3周期性循環顯(xian)示外(注意:此指電(dian)機在運轉時的(de)狀態,若電(dian)機未轉,該三燈(deng)為隨機狀態),其(qi)它各(ge)燈(deng)均亮。

·驅動扳(兩邊的(de)兩塊(kuai)):其上面各指示燈均亮并有(you)輕微閃爍。

7、當電機(ji)定子電流出現異常大幅擺動時,應立即退相(xiang),查出原因并檢(jian)修后投入使用。

8、定期打掃柜內(nei)衛生。

十一故(gu)障處(chu)理



主(zhu)電機不能起動(dong)

端子363、369無380V 電源

檢查起動(dong)柜控制電(dian)源

 

接觸器KM11不吸合

檢查KM11線包及其控制回路

 

接觸器KM11吸合,但其輔助觸點未閉合

檢修其(qi)輔助觸點

 

端子359、361串入合閘回路的線未接通

檢查(cha)該(gai)回路

不能投入(ru)進相(xiang)

空氣開關QF1、QF2、QF3沒合上

合上(shang)空氣開關

 

按鈕STP、ST接觸不良

 

 

中間繼電器KA11觸點接觸不良

 

 

主電機起動柜內星點接觸器常開輔助觸點不能閉合(225、227未接通)

檢修該接觸器輔助觸點及連線

 

KM13不能吸合

檢查KM13線包及其控制回路

 

固態繼電器FV損壞或者不導通

控制器主控制板L6燈滅

檢查主控板7腳對11、12、13腳有無+、-3伏左右電壓,否則更換電流傳感器

 

 

檢查固態繼電器FV

FV的3、4腳有直流15V電壓,而(er)323、325不通,須更(geng)換該繼電器

進相后主(zhu)電機(ji)停(ting)機(ji)

接入開關柜的KM11、KM13的輔助觸點359、361接觸不好

維修(xiu)該觸(chu)點

 

進相器投(tou)入(ru)進相瞬間外部空(kong)氣開關(guan)跳閘(zha)

更換大規(gui)格的空氣開(kai)關

進相后無(wu)效果

接(jie)入主控板的電流傳感器(qi)信(xin)號線錯誤(wu)

電流傳感器從左到右TA1、TA2、TA3的信號線應分別對應與主控板的13、12、11腳

 

主控板的撥(bo)碼開關(guan)在自檢位

撥碼開(kai)關撥至工作位(wei)

 

KM13吸合(he)后KM11未(wei)釋放(時間繼電器KT11壞(huai))

更換KT11時間繼電器

 

KM15沒有吸合(he)

KM11的輔(fu)助觸(chu)點301、305接觸(chu)不(bu)良

維(wei)修該觸(chu)點

 

 

KM15線圈故障

更換KM15線圈

 

KM15主觸點接觸不良

更換KM15

 

主變壓器原邊開路

更(geng)換主變壓器

進(jin)相后(hou)主電機(ji)電流(liu)不減反(fan)增

同步(bu)電源相(xiang)序錯(cuo)誤

調換進相器內小變壓器TC上輸出6V、6V0電壓的兩線位置

 

電機轉速下降(缺相),自(zi)動退相

KM13主觸點接觸不良

維修該觸點

 

 

電(dian)機轉子線(xian)松動,進相時的(de)電(dian)流沖擊(ji)導致缺相

檢查(cha)電機轉子線

進相(xiang)后(hou)主(zhu)電機電流擺動大(da)

可控(kong)硅擊穿

測(ce)量可控硅極間電阻(詳細方法見調試部(bu)分)

 

觸發板損壞

測量可控硅控制極與陰極之間應有0.2V以上的直流電壓信號,否則應檢查觸發板

 

主(zhu)板的撥(bo)碼開關(guan)在自(zi)檢位(wei)

撥(bo)碼開關撥(bo)至(zhi)工作(zuo)位

 

電機轉子線松動(dong)

檢查電(dian)機轉子線

 

KM13采用節能型線圈時,線圈故障導致KM13進行瞬間來回釋放、吸合,導致主回路接觸不良

維修或更換KM13線圈





注意:進相器檢修不(bu)得在進(jin)相狀態下進(jin)行,發現問題(ti)應立即退相。

十二控制板檢修(xiu)



現象(xiang)

原因

對策

L1L2L3不循環閃爍,L6滅,其它各燈正常

轉子缺相

檢查接觸器KM2主觸頭是否損壞,若損壞,則維修觸頭或更換接觸器

電流傳感器器損(sun)壞

檢查電流傳感器是否有±2V以上的輸出信號,否則更換傳感器

主控(kong)板(ban)元器件損壞

依次更換IC210IC211

L1L2L3不周期性閃爍,其它各燈正常

主控板元器(qi)件(jian)損壞

依次更換IC210IC211IC205IC207

L6滅,其它各燈正常

主控(kong)板元器件損壞

依次更換IC207IC209

L5滅,其它各燈正常

散熱器(qi)溫度檢(jian)測回(hui)路故障(zhang)

檢查溫(wen)度開(kai)關(guan)及其連線

L4L7L8全部或部分滅

電源故障

1、檢查變壓器及控制板是否有±18V電源

2、更換相應的780578157915

F1-L1L6 F2-L1L6部分指示燈亮,主板各燈正常

觸發(fa)板元器件損壞(huai)

1、有一片ULN2004損壞,更換之

2、脈沖變壓器接觸不良,作相應處理

F1-L1L6 F2-L1L6指示燈全滅,主板各燈正常

觸發板元器件損壞

1、兩片ULN2004損壞,更換之

2、更換555芯片

觸(chu)發板(ban)無(wu)電(dian)源

1、檢查主板7815是否有虛焊

2、檢查觸發板19腳與主板6腳連接是否正常





十三(san)注意事(shi)項

1、進相器(qi)檢修(xiu)應在退相狀態下(xia)進行,發現問題應立即退相。

2、嚴(yan)禁隨意帶電插拔(ba)控制(zhi)板(ban),檢修控制(zhi)板(ban)時(shi),一定要把空開QF3打下來。

3、更換可(ke)控(kong)(kong)硅(gui)時(shi)應注意陰、陽(yang)極的(de)方(fang)向,并(bing)壓緊散熱器(qi)(壓力不要過大),裝上后擰緊所有螺絲,之后再(zai)檢測可(ke)控(kong)(kong)硅(gui)各(ge)極間的(de)電(dian)阻情況。若一只可(ke)控(kong)(kong)硅(gui)擊穿在柜體上直(zhi)接檢測,同一相(xiang)的(de)四個可(ke)控(kong)(kong)硅(gui)均(jun)顯示擊穿,此時(shi)應把該組可(ke)控(kong)(kong)硅(gui)間的(de)聯接銅排拆掉再(zai)測 。

十(shi)四訂貨須知

1、提供電(dian)(dian)機型號(hao)、額(e)定(ding)功率、定(ding)子(zi)電(dian)(dian)壓(ya)、定(ding)子(zi)電(dian)(dian)流、轉子(zi)電(dian)(dian)壓(ya)、轉子(zi)電(dian)(dian)流、額(e)定(ding)功率因(yin)數。

2、提供電機拖動負載(zai)的(de)特征及負載(zai)率。

預知(zhi)TP系列無環流靜止式進相器的更多信息,請(qing)撥打襄(xiang)陽拓邦電(dian)(dian)氣官網電(dian)(dian)話: 鄭(zheng)經理17771133316或咨(zi)詢網站(zhan)客服(fu)!!

在線留言

LEAVE A MESSAGE