TP系列無環流靜止式進相器是(shi)襄陽拓(tuo)邦電(dian)(dian)(dian)氣自(zi)選研制開發的(de)(de)新一(yi)代高(gao)新技術產(chan)品,是(shi)一(yi)種(zhong)(zhong)專(zhuan)為(wei)大中型繞線式(shi)異(yi)步電(dian)(dian)(dian)動機(ji)設計制作的(de)(de)就(jiu)地無功(gong)功(gong)率(lv)補償裝置。它串接于電(dian)(dian)(dian)機(ji)轉(zhuan)子回路,改(gai)變(bian)轉(zhuan)子電(dian)(dian)(dian)流(liu)與(yu)(yu)轉(zhuan)子電(dian)(dian)(dian)壓的(de)(de)相(xiang)位關(guan)系(xi),通過(guo)磁場進而改(gai)變(bian)電(dian)(dian)(dian)機(ji)定(ding)(ding)子電(dian)(dian)(dian)流(liu)與(yu)(yu)電(dian)(dian)(dian)壓的(de)(de)相(xiang)位關(guan)系(xi),達到提高(gao)電(dian)(dian)(dian)機(ji)自(zi)身功(gong)率(lv)因數、降低電(dian)(dian)(dian)機(ji)定(ding)(ding)子電(dian)(dian)(dian)流(liu)和溫升(sheng)的(de)(de)目(mu)的(de)(de)。這種(zhong)(zhong)方(fang)式(shi)從(cong)根本上(shang)改(gai)善了(le)電(dian)(dian)(dian)機(ji)的(de)(de)運行狀(zhuang)況,顯著降低電(dian)(dian)(dian)機(ji)及電(dian)(dian)(dian)網的(de)(de)無功(gong)損(sun)耗,對節(jie)能(neng)降耗、降低單位產(chan)品成本,提高(gao)企業的(de)(de)經濟效益具有重要(yao)的(de)(de)意(yi)義。
TP系列無(wu)(wu)環流靜止式進(jin)相(xiang)器對(dui)無(wu)(wu)功(gong)功(gong)率的(de)(de)補(bu)償(chang)(chang)與電機(ji)定子側并聯(lian)電容(rong)器的(de)(de)補(bu)償(chang)(chang)有著本質的(de)(de)區別。電容(rong)補(bu)償(chang)(chang)只是在電機(ji)之(zhi)外的(de)(de)電網(wang)上(shang)對(dui)無(wu)(wu)功(gong)進(jin)行補(bu)償(chang)(chang),減少(shao)電網(wang)的(de)(de)無(wu)(wu)功(gong)輸(shu)入,電網(wang)的(de)(de)功(gong)率因(yin)數得(de)到提高,但是電機(ji)的(de)(de)無(wu)(wu)功(gong)消耗并沒有減少(shao),無(wu)(wu)法改善電機(ji)本身(shen)的(de)(de)運行狀況(kuang);而TP系列靜止式進相器是串接在電機(ji)(ji)轉(zhuan)子(zi)(zi)回路中,不僅可顯著(zhu)提(ti)高(gao)功率因數,使(shi)電機(ji)(ji)定子(zi)(zi)電流(liu)大幅度降低,而且電機(ji)(ji)溫升明顯降低,電機(ji)(ji)的效率和過載(zai)能力顯著(zhu)提(ti)高(gao)。
TP系(xi)列(lie)靜止(zhi)式(shi)(shi)進(jin)(jin)(jin)相(xiang)(xiang)(xiang)器與自(zi)激(旋(xuan)轉)式(shi)(shi)進(jin)(jin)(jin)相(xiang)(xiang)(xiang)機(ji)(ji)(ji)也不同。TP系(xi)列(lie)靜止(zhi)式(shi)(shi)進(jin)(jin)(jin)相(xiang)(xiang)(xiang)器采(cai)用(yong)了 的交-交變頻(pin)技(ji)術和微(wei)機(ji)(ji)(ji)、可控(kong)硅控(kong)制技(ji)術,可自(zi)動跟蹤電機(ji)(ji)(ji)運行狀態(tai)的變化并(bing)自(zi)動調整(zheng)相(xiang)(xiang)(xiang)關參數以達到(dao)(dao)佳的補償效果,這(zhe)是自(zi)激式(shi)(shi)進(jin)(jin)(jin)相(xiang)(xiang)(xiang)機(ji)(ji)(ji)無法做到(dao)(dao)的。而且,TP系(xi)列(lie)靜止(zhi)式(shi)(shi)進(jin)(jin)(jin)相(xiang)(xiang)(xiang)器從根本上(shang)克服了自(zi)激式(shi)(shi)進(jin)(jin)(jin)相(xiang)(xiang)(xiang)機(ji)(ji)(ji)“整(zheng)流子”結(jie)構特別怕塵埃、壽命(ming)短、維修頻(pin)繁的缺(que)點;具有參數調節容易、主回路無轉動部件、不怕灰(hui)塵、可靠性高、使(shi)用(yong)壽命(ming)長、維護方便,是理(li)想的取代自(zi)激式(shi)(shi)進(jin)(jin)(jin)相(xiang)(xiang)(xiang)機(ji)(ji)(ji)的新型高科技(ji)產品。
TP系列(lie)靜止式進相器可廣泛用于水泥、化工、礦山(shan)、冶金、鋼鐵、造紙、制藥(yao)等行業的大(da)中型高低壓繞線式異步(bu)電機。
二型號命(ming)名
TP系列靜止式進相器型號命名方(fang)法如(ru)下:
型號(hao):TP-800,表示適用于(yu)額定轉子電(dian)流不超過(guo)800A的電(dian)機的靜止式進相器。
三工(gong)作原理(li)
當電(dian)機運行(xing)進(jin)相(xiang)(xiang)(xiang)時,進(jin)相(xiang)(xiang)(xiang)器(qi)通(tong)(tong)過轉(zhuan)子電(dian)流(liu)傳感(gan)器(qi)采集到的(de)(de)轉(zhuan)子電(dian)流(liu)信號及工(gong)頻(pin)電(dian)壓(ya)提供的(de)(de)同步信號經微(wei)處理(li)器(qi)CPU進(jin)行(xing)數據和(he)相(xiang)(xiang)(xiang)位處理(li),控制可(ke)控硅的(de)(de)觸發信號,調整由12只晶閘管組成的(de)(de)交(jiao)—交(jiao)變(bian)頻(pin)裝置,將降壓(ya)后的(de)(de)工(gong)頻(pin)電(dian)源(yuan)變(bian)為和(he)轉(zhuan)子電(dian)流(liu)同頻(pin)率,相(xiang)(xiang)(xiang)位滯后90°的(de)(de)附(fu)加(jia)電(dian)勢加(jia)在電(dian)機轉(zhuan)子回路中。轉(zhuan)子的(de)(de)電(dian)流(liu)和(he)電(dian)壓(ya)相(xiang)(xiang)(xiang)位因(yin)此改(gai)變(bian),通(tong)(tong)過磁場進(jin)而改(gai)變(bian)電(dian)機定子電(dian)流(liu)與定子電(dian)壓(ya)的(de)(de)相(xiang)(xiang)(xiang)位角,使電(dian)機的(de)(de)功率因(yin)數提高,得到補(bu)償。
當電機在(zai)某(mou)一(yi)負(fu)載下(xia)運行(xing)時,其轉子電流為I2e、定子電流為I1e, 向(xiang)量圖如下(xia)所示。
從(cong)(cong)電機(ji)學我們知道,激磁(ci)(ci)電流(liu)Im由關(guan)系式Im=I1e-I2e,從(cong)(cong)向(xiang)(xiang)量圖(tu)可(ke)得(de)出Im。當進相(xiang)器的電勢疊加(jia)在轉(zhuan)子回(hui)路后,轉(zhuan)子電流(liu)的相(xiang)位變(bian)(bian)為圖(tu)中的I2。由于(yu)負載(zai)不變(bian)(bian),激磁(ci)(ci)電流(liu)Im不變(bian)(bian)。此時的定(ding)子電流(liu)I1由關(guan)系式I1=Im+I2從(cong)(cong)向(xiang)(xiang)量圖(tu)可(ke)得(de)出I1,如圖(tu)所(suo)示。從(cong)(cong)圖(tu)中可(ke)以(yi)看出I1的功(gong)率(lv)因數角和幅值都比I1e小,說明電機(ji)的功(gong)率(lv)因數有(you)(you)所(suo)提(ti)高,定(ding)子電流(liu)有(you)(you)所(suo)下降。
進相(xiang)器就是(shi)這(zhe)樣改(gai)變轉子(zi)電(dian)(dian)流與轉子(zi)電(dian)(dian)壓(ya)(ya)的相(xiang)位關(guan)系(xi),通過磁場進而改(gai)變電(dian)(dian)機(ji)定子(zi)電(dian)(dian)流與定子(zi)電(dian)(dian)壓(ya)(ya)的相(xiang)位關(guan)系(xi),減小功率因數角(jiao),終使電(dian)(dian)機(ji)本身的功率因數得(de)以提高,定子(zi)電(dian)(dian)流得(de)以下降,達(da)到對電(dian)(dian)機(ji)補償(chang)的目的。
當負載(zai)發生改變(bian)時,微處理(li)器實時檢測(ce)電(dian)機參數的(de)變(bian)化,并(bing)根據(ju)負載(zai)的(de)變(bian)化,動(dong)態調整附加在轉子上的(de)電(dian)勢(shi)幅值,以使(shi)電(dian)機的(de)功率(lv)因數始終保(bao)持在期望值上。
四原(yuan)理框圖
電容式補(bu)償的矢量分析(xi):
電容補償和進相器補償的(de)原理(li)圖(tu)分別(bie)如下:
圖中,將電(dian)機(ji)進行(xing)了等(deng)效(xiao)簡化(hua),R1、X1為電(dian)機(ji)定子等(deng)效(xiao)電(dian)路的電(dian)阻(zu)和(he)電(dian)感(gan)(gan),R2、X2為電(dian)機(ji)轉子等(deng)效(xiao)電(dian)路的電(dian)阻(zu)和(he)電(dian)感(gan)(gan),C為就地補償的電(dian)容(rong),Uf為進相(xiang)器的等(deng)效(xiao)電(dian)路,M為電(dian)機(ji)的接線點。
從圖可以看出,靜(jing)止式(shi)進(jin)(jin)(jin)相器和電容(rong)補償(chang)對(dui)電機(ji)(ji)的作用點(dian)(dian)不(bu)同(tong),電容(rong)是在(zai)(zai)電機(ji)(ji)的前端(duan)定子側進(jin)(jin)(jin)行補償(chang),其(qi)補償(chang)范(fan)圍是在(zai)(zai)補償(chang)點(dian)(dian)的前端(duan);靜(jing)止式(shi)進(jin)(jin)(jin)相器串聯在(zai)(zai)電機(ji)(ji)的后端(duan),其(qi)補償(chang)范(fan)圍擴大到了(le)電機(ji)(ji)。
五性能(neng)特點(dian)
1、可使電機的功率因數提高到0.95以(yi)上,無(wu)功功率降低60%以(yi)上。
2、降(jiang)低定子電流10%-20%。
3、降低線損(sun)、銅損(sun)20%-30%。
4、電機(ji)溫升降(jiang)低(di)5%。
5、過載(zai)能力和效率大大提高,電機使用(yong)壽命延長。
6、具(ju)有故障自動保護功能,保障設備(bei)長期安全運行。
7、操(cao)作簡單,安(an)裝調試和(he)維修保養均不影(ying)響正常生產,半(ban)年(nian)內(nei)可收(shou)回成(cheng)本。
六使用條(tiao)件
1、安裝地點環境溫度≤40℃
2、安裝地點相(xiang)對濕(shi)度(du)≤90%
3、 安裝地(di)點無火災(zai)、爆炸危(wei)險品,無化(hua)學腐蝕及劇烈振(zhen)動。
4、海拔高度≤1500M。
5、進相器柜(ju)體上(shang)方0.5米(mi)內應通風(feng);如無地(di)溝(gou),須將(jiang)進相器柜(ju)體架空0.1米(mi)。
注:TP系列靜止式進相器應滿(man)足(zu)上方(fang)要求(qiu)的使用條件,襄陽拓邦電氣還可提供(gong)適用(yong)于高原地區(海拔超過1500米)的(de)靜止式進相器(但用(yong)戶須(xu)事先特別(bie)申(shen)請)。
七技術參(can)數(shu)
進 相 器 型 號 |
適 配 電 機 參 數 |
|
額定轉子電流(A) |
額定功率(KW) |
|
TP-400 |
≤400 |
95-800 |
TP-500 |
400-500 |
245-1000 |
TP-600 |
500-600 |
315-1250 |
TP-800 |
600-800 |
630-1600 |
TP-1000 |
800-1000 |
1000-2000 |
TP-1200 |
1000-1200 |
1600-2500 |
TP-1500 |
1200-1500 |
2000以上 |
八(ba)安裝尺寸
1、外型(xing)尺寸圖
2、安裝基礎(chu)圖(tu)
3、規格尺寸表
型號 |
外形尺寸(MM) |
安裝尺寸(MM) |
||||
寬(W) |
深(D) |
高(H) |
寬(E) |
深(F) |
螺孔 |
|
TP400-600 |
1000 |
760 |
2000 |
780 |
620 |
14 |
TP800-1000 |
1100 |
800 |
2000 |
880 |
650 |
14 |
TP1200-1500 |
1200 |
900 |
2200 |
980 |
750 |
16 |
注(zhu):隨著產品不斷更新換(huan)代,外形及安裝尺寸會(hui)有所變化,請以具體的產品為準。
九安裝調試
(一)安裝(zhuang)
1、將進相(xiang)器搬到安裝位置,注意進相(xiang)器柜(ju)體(ti)底部(bu)應(ying)與地溝相(xiang)通或架空(kong),首先是(shi)打開柜(ju)子的前后門,從上到下(xia),逐(zhu)一地擰緊螺絲,防止在(zai)運輸(shu)過程(cheng)中螺絲松動造成進相(xiang)器不能正(zheng)常工作。
2、準備好連(lian)接【主電(dian)機轉子至進(jin)相器接觸器KM13的三根電(dian)纜】、【進(jin)相器接觸器KM11至主電(dian)機起動柜(ju)的三根電(dian)纜】,其線徑(jing)應(ying)能承載主電(dian)機轉子額定電(dian)流(liu),比好長度并壓(ya)好接頭。
3、進(jin)相器(qi)(qi)上(shang)的電(dian)(dian)(dian)(dian)流表、功(gong)率因數表是直接(jie)從(cong)電(dian)(dian)(dian)(dian)機定(ding)子(zi)回路(lu)上(shang)的電(dian)(dian)(dian)(dian)流互(hu)(hu)(hu)感(gan)器(qi)(qi)、電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)互(hu)(hu)(hu)感(gan)器(qi)(qi)取信(xin)號,要求(qiu)所(suo)用電(dian)(dian)(dian)(dian)流互(hu)(hu)(hu)感(gan)器(qi)(qi)副邊的額定(ding)電(dian)(dian)(dian)(dian)流為5A、電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)互(hu)(hu)(hu)感(gan)器(qi)(qi)副邊的額定(ding)電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)為100V,若(ruo)用戶現用的不(bu)滿足該要求(qiu),則須另(ling)行準備符合上(shang)述要求(qiu)的互(hu)(hu)(hu)感(gan)器(qi)(qi)。(注(zhu):電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)互(hu)(hu)(hu)感(gan)器(qi)(qi)僅(jin)適用于高壓(ya)(ya)(ya)(ya)電(dian)(dian)(dian)(dian)機,對低(di)壓(ya)(ya)(ya)(ya)電(dian)(dian)(dian)(dian)機,進(jin)相器(qi)(qi)電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)信(xin)號直接(jie)從(cong)定(ding)子(zi)回路(lu)取)
4、新電機(ji)須(xu)帶上90%以(yi)上負載(zai)并正常(chang)運轉后才可調(diao)(diao)試進(jin)相器,用戶在(zai)通知(zhi)我方調(diao)(diao)試前,應調(diao)(diao)試好電機(ji)、減速機(ji)、磨機(ji)等其它設(she)備,使其帶上負載(zai)正常(chang)運轉,以(yi)免延誤進(jin)相器調(diao)(diao)試時間。
5、各聯鎖線(xian)意義如下:
(225、227)取自電機起動(dong)柜星點短接(jie)接(jie)觸器(qi)的輔(fu)助常開點,只有在(zai)電機起動(dong)完畢后,進相器(qi)才可(ke)以進相。
(355、357)當(dang)開(kai)關柜主(zhu)開(kai)關是接觸器(qi)時(shi)與分(fen)閘(zha)按鈕并(bing)聯(lian);是斷路(lu)器(qi)時(shi)與分(fen)閘(zha)按鈕串(chuan)聯(lian), 進相狀態下主(zhu)電(dian)機不能停機,只有先(xian)退相才(cai)能停主(zhu)機。
(359、361)串入開(kai)關柜(ju)合(he)閘回路。當KM11吸合(he)時,可以(yi)起動電機(ji)。
(363、369)從起(qi)(qi)動(dong)柜控制電(dian)源引(yin)單相380V,使KM11與起(qi)(qi)動(dong)柜控制回路同(tong)時得電(dian)。
(30、32)串入主電機電流計量回路;(40、42)并入主電機電壓(ya)(ya)(ya)計量回路。(取A相(xiang)電流則取B,C相(xiang)電壓(ya)(ya)(ya),如此類推(tui),電流和電壓(ya)(ya)(ya)不得取同相(xiang))。
(A、B、C、N)接(jie)三相四(si)線電源(yuan),導(dao)線橫(heng)截面積:TP600以(yi)下(xia)用(yong)4mm2;TP1000以(yi)下(xia)用(yong)6mm2;TP1500以(yi)下(xia)用(yong)10mm2。
6、控(kong)制器所有指(zhi)示燈的含(han)義(yi)說明(ming)如(ru)下:
(1)主板(ban)(中間一塊)的指示燈(從上往下數)
●L1、L2、L3:電(dian)機轉(zhuan)子三相電(dian)流信號指(zhi)示(電(dian)機運轉(zhuan)時為循環顯示狀(zhuang)態;自檢試驗(yan)時為隨(sui)機狀(zhuang)態:或亮、或滅)
●L4:+5V電源指(zhi)示(保(bao)持亮(liang)的狀態)
●L5:熱(re)故(gu)障(zhang)指(zhi)示(有熱(re)故(gu)障(zhang)時(shi)L5滅)
●L6:缺相及自(zi)動(dong)故障(zhang)(zhang)保護指示(有缺相故障(zhang)(zhang)及其(qi)它故障(zhang)(zhang)時L6燈滅)
●L7:+15V電(dian)源指(zhi)示(shi)(保持亮的狀態)
●L8:-15V電源指示(保持亮(liang)的狀(zhuang)態)
(2)驅(qu)動板(ban)(兩邊兩塊)
●分別(bie)代表12個可控制硅(gui)的觸發信號(指示燈均(jun)亮(liang),并(bing)有規律(lv)的閃爍(shuo))
(二(er))試(shi)驗
1、檢查主電纜、聯鎖線、儀表線連接是否正確(que)。
2、檢查各器(qi)件(jian)螺絲是否緊固。
3、用萬用表測量(liang)可控硅極間電阻:
●觸發極(ji)G與(yu)陰極(ji)K間電阻為幾十歐姆;
●觸發極G與(yu)陽(yang)極A間(jian)電(dian)阻大于幾十千歐;
●陰極K與(yu)陽(yang)極A間電阻(zu)大于幾十(shi)千歐;
●陰極K與陽極A用(yong)(yong)萬用(yong)(yong)表200K檔測量,阻值應從小變化到無(wu)限(xian)大。
4、合(he)上(shang)起動柜(ju)電(dian)源,進相(xiang)器背面(mian)的接觸(chu)器KM11應吸合(he),短接225、227;合(he)上(shang)進相(xiang)器電(dian)源,電(dian)源指示燈亮;控制器應有(you)電(dian),控制器上(shang)指示燈亮。
5、控制(zhi)器(qi)上撥碼開關打在ON(上方)位置,中間主板L1、L2、L3循(xun)環亮或(huo)滅(mie),L4~L8全亮;兩邊兩塊驅(qu)動板指示燈閃爍。
6、按綠色進(jin)相(xiang)按鈕,進(jin)相(xiang)器前面(mian)的接(jie)觸(chu)器KM13吸合(he),延時(shi)后,背面(mian)的接(jie)觸(chu)器KM11斷(duan)開,綠色進(jin)相(xiang)指示(shi)燈(deng)亮,風機運轉,風應向上吹(chui),主(zhu)變壓器副(fu)邊電流不超過30A,并且(qie)沒(mei)有大幅度(du)變化。
7、按紅色(se)退(tui)相按鈕,進(jin)(jin)(jin)(jin)相器(qi)后(hou)面(mian)的接觸(chu)器(qi)KM11吸(xi)合,延時后(hou),前面(mian)的接觸(chu)器(qi)KM13斷開,綠色(se)進(jin)(jin)(jin)(jin)相指示燈滅(mie),紅色(se)電源(yuan)指示燈亮,進(jin)(jin)(jin)(jin)相器(qi)即退(tui)出進(jin)(jin)(jin)(jin)相狀態。
8、通電試驗結束,請務(wu)必(bi)斷開225、227。
(三)調試
1、運(yun)行前:控(kong)制(zhi)器主板上撥碼開(kai)關應(ying)打在OFF(下方)位置。
2、起(qi)動(dong)主電(dian)機:打開進相器前柜(ju)門,合上(shang)空氣開關,進相器電(dian)源(yuan)接通,面板上(shang)的紅色電(dian)源(yuan)指示燈亮(liang),關閉(bi)柜(ju)門,等待主機起(qi)動(dong)。
3、進相(xiang):(1)電機正常運轉后,按(an)(an)綠色進相(xiang)按(an)(an)鈕,進相(xiang)器前面的(de)接(jie)觸(chu)器KM13吸合(he),延(yan)時后,背面的(de)接(jie)觸(chu)器KM11斷開,綠色進相(xiang)指示(shi)燈亮(liang),風機運轉,定(ding)子(zi)電流(liu)應下降,功(gong)率因數應上(shang)升。如(ru)果定(ding)子(zi)電流(liu)不下降反(fan)而上(shang)升,調整同步變壓器上(shang)6V、6V0兩線的(de)位(wei)置,再進相(xiang)。
(2)測量(liang)主變壓器原(yuan)、副邊電流(liu),應無(wu)大幅(fu)度(du)擺動(dong)。
(3)電機定子電流應平穩,無(wu)大幅度(du)擺動。
(4)六(liu)個電抗器上端銅(tong)排的電流(liu)擺動幅度應一致。
4、退相:按(an)紅色退相按(an)鈕,進(jin)相器后面的接觸(chu)器KM11吸合,延時后,前面的接觸(chu)器KM13斷開(kai),綠(lv)色進(jin)相指示燈滅,紅色電源(yuan)指示燈亮,進(jin)相器即(ji)退出進(jin)相狀態。
5、停車(che):進相器退相后,按下主機(ji)停車(che)按鈕,電機(ji)即停車(che)。
(四)測量(liang)和觀察
1、測量可控硅、銅排、交流接觸器、電抗器、主變(bian)壓器、控制板(ban)溫度。
2、測量可控硅(gui)觸(chu)發(fa)電(dian)壓;主變壓器一次、二次電(dian)流(liu);電(dian)抗(kang)器輸入電(dian)流(liu)。
3、觀(guan)察(cha)風機運行情(qing)況。
4、觀察整(zheng)體運行情況,有無(wu)異常響聲(sheng)或銅排有無(wu)大(da)的(de)抖動(dong)現象等。
十使用維護
為確保TP系列靜止式進相器長期安全(quan)、可靠(kao)地運行,請操(cao)作人員特別注意以下事項:
1、嚴禁在進相(xiang)器運行期間,切斷進相(xiang)器外(wai)部電源。
2、定期檢查(cha)冷(leng)卻風機(ji)運轉(zhuan)狀(zhuang)況(kuang),冷(leng)卻風機(ji)停(ting)轉(zhuan)使可(ke)(ke)控硅散熱(re)能力下降,可(ke)(ke)能燒壞可(ke)(ke)控硅。
3、定期檢測主(zhu)變壓器原、副邊運行(xing)電(dian)流。
4、定期檢測可控硅、聯接(jie)銅排、交流接(jie)觸器(qi)、電抗器(qi)、主(zhu)變(bian)壓器(qi)、控制板(ban)的溫度。
5、定期檢修主回路接觸器(qi)的觸頭。真空(kong)接觸器(qi)定期檢測絕緣(yuan)電(dian)阻(zu)(zu),用(yong)5KV或2.5KV搖表檢查,當開關(guan)管(guan)絕緣(yuan)電(dian)阻(zu)(zu)小于(yu)100兆歐(ou)時,應加強監視,小于(yu)20兆歐(ou)時應立即更換新(xin)管(guan),以(yi)延長(chang)接觸器(qi)的使(shi)用(yong)壽命,保(bao)障進(jin)相器(qi)及電(dian)機安(an)全運(yun)行(xing)。
6、當進相器停用一(yi)段時間又重新啟用時, 次進相前(qian)應觀察(cha)柜內控制單元上各指示(shi)燈(deng)(deng)是否(fou)正常。電(dian)機起動并正常運轉后,各指示(shi)燈(deng)(deng)顯示(shi)如下:
·主板(中(zhong)間一塊):除L1,L2,L3周期性循環顯(xian)示外(注意:此指電(dian)機在運轉時的(de)狀態,若電(dian)機未轉,該三燈(deng)為隨機狀態),其(qi)它各(ge)燈(deng)均亮。
·驅動扳(兩邊的(de)兩塊(kuai)):其上面各指示燈均亮并有(you)輕微閃爍。
7、當電機(ji)定子電流出現異常大幅擺動時,應立即退相(xiang),查出原因并檢(jian)修后投入使用。
8、定期打掃柜內(nei)衛生。
十一故(gu)障處(chu)理
主(zhu)電機不能起動(dong) |
端子363、369無380V 電源 |
檢查起動(dong)柜控制電(dian)源 |
||
|
接觸器KM11不吸合 |
檢查KM11線包及其控制回路 |
||
|
接觸器KM11吸合,但其輔助觸點未閉合 |
檢修其(qi)輔助觸點 |
||
|
端子359、361串入合閘回路的線未接通 |
檢查(cha)該(gai)回路 |
||
不能投入(ru)進相(xiang) |
空氣開關QF1、QF2、QF3沒合上 |
合上(shang)空氣開關 |
||
|
按鈕STP、ST接觸不良 |
|
||
|
中間繼電器KA11觸點接觸不良 |
|
||
|
主電機起動柜內星點接觸器常開輔助觸點不能閉合(225、227未接通) |
檢修該接觸器輔助觸點及連線 |
||
|
KM13不能吸合 |
檢查KM13線包及其控制回路 |
||
|
固態繼電器FV損壞或者不導通 |
控制器主控制板L6燈滅 |
檢查主控板7腳對11、12、13腳有無+、-3伏左右電壓,否則更換電流傳感器 |
|
|
|
檢查固態繼電器FV |
FV的3、4腳有直流15V電壓,而(er)323、325不通,須更(geng)換該繼電器 |
|
進相后主(zhu)電機(ji)停(ting)機(ji) |
接入開關柜的KM11、KM13的輔助觸點359、361接觸不好 |
維修(xiu)該觸(chu)點 |
||
|
進相器投(tou)入(ru)進相瞬間外部空(kong)氣開關(guan)跳閘(zha) |
更換大規(gui)格的空氣開(kai)關 |
||
進相后無(wu)效果 |
接(jie)入主控板的電流傳感器(qi)信(xin)號線錯誤(wu) |
電流傳感器從左到右TA1、TA2、TA3的信號線應分別對應與主控板的13、12、11腳 |
||
|
主控板的撥(bo)碼開關(guan)在自檢位 |
撥碼開(kai)關撥至工作位(wei) |
||
|
KM13吸合(he)后KM11未(wei)釋放(時間繼電器KT11壞(huai)) |
更換KT11時間繼電器 |
||
|
KM15沒有吸合(he) |
KM11的輔(fu)助觸(chu)點301、305接觸(chu)不(bu)良 |
維(wei)修該觸(chu)點 |
|
|
|
KM15線圈故障 |
更換KM15線圈 |
|
|
KM15主觸點接觸不良 |
更換KM15 |
||
|
主變壓器原邊開路 |
更(geng)換主變壓器 |
||
進(jin)相后(hou)主電機(ji)電流(liu)不減反(fan)增 |
同步(bu)電源相(xiang)序錯(cuo)誤 |
調換進相器內小變壓器TC上輸出6V、6V0電壓的兩線位置 |
||
|
電機轉速下降(缺相),自(zi)動退相 |
KM13主觸點接觸不良 |
維修該觸點 |
|
|
|
電(dian)機轉子線(xian)松動,進相時的(de)電(dian)流沖擊(ji)導致缺相 |
檢查(cha)電機轉子線 |
|
進相(xiang)后(hou)主(zhu)電機電流擺動大(da) |
可控(kong)硅擊穿 |
測(ce)量可控硅極間電阻(詳細方法見調試部(bu)分) |
||
|
觸發板損壞 |
測量可控硅控制極與陰極之間應有0.2V以上的直流電壓信號,否則應檢查觸發板 |
||
|
主(zhu)板的撥(bo)碼開關(guan)在自(zi)檢位(wei) |
撥(bo)碼開關撥(bo)至(zhi)工作(zuo)位 |
||
|
電機轉子線松動(dong) |
檢查電(dian)機轉子線 |
||
|
當KM13采用節能型線圈時,線圈故障導致KM13進行瞬間來回釋放、吸合,導致主回路接觸不良 |
維修或更換KM13線圈 |
注意:進相器檢修不(bu)得在進(jin)相狀態下進(jin)行,發現問題(ti)應立即退相。
十二控制板檢修(xiu)
現象(xiang) |
原因 |
對策 |
L1、L2、L3不循環閃爍,L6滅,其它各燈正常 |
轉子缺相 |
檢查接觸器KM2主觸頭是否損壞,若損壞,則維修觸頭或更換接觸器 |
電流傳感器器損(sun)壞 |
檢查電流傳感器是否有±2V以上的輸出信號,否則更換傳感器 |
|
主控(kong)板(ban)元器件損壞 |
依次更換IC210、IC211 |
|
L1、L2、L3不周期性閃爍,其它各燈正常 |
主控板元器(qi)件(jian)損壞 |
依次更換IC210、IC211、IC205、IC207 |
L6滅,其它各燈正常 |
主控(kong)板元器件損壞 |
依次更換IC207、IC209 |
L5滅,其它各燈正常 |
散熱器(qi)溫度檢(jian)測回(hui)路故障(zhang) |
檢查溫(wen)度開(kai)關(guan)及其連線 |
L4、L7、L8全部或部分滅 |
電源故障 |
1、檢查變壓器及控制板是否有±18V電源 2、更換相應的7805、7815、7915 |
F1-L1~L6 或F2-L1~L6部分指示燈亮,主板各燈正常 |
觸發(fa)板元器件損壞(huai) |
1、有一片ULN2004損壞,更換之 2、脈沖變壓器接觸不良,作相應處理 |
F1-L1~L6 或F2-L1~L6指示燈全滅,主板各燈正常 |
觸發板元器件損壞 |
1、兩片ULN2004損壞,更換之 2、更換555芯片 |
觸(chu)發板(ban)無(wu)電(dian)源 |
1、檢查主板7815是否有虛焊 2、檢查觸發板19腳與主板6腳連接是否正常 |
十三(san)注意事(shi)項
1、進相器(qi)檢修(xiu)應在退相狀態下(xia)進行,發現問題應立即退相。
2、嚴(yan)禁隨意帶電插拔(ba)控制(zhi)板(ban),檢修控制(zhi)板(ban)時(shi),一定要把空開QF3打下來。
3、更換可(ke)控(kong)(kong)硅(gui)時(shi)應注意陰、陽(yang)極的(de)方(fang)向,并(bing)壓緊散熱器(qi)(壓力不要過大),裝上后擰緊所有螺絲,之后再(zai)檢測可(ke)控(kong)(kong)硅(gui)各(ge)極間的(de)電(dian)阻情況。若一只可(ke)控(kong)(kong)硅(gui)擊穿在柜體上直(zhi)接檢測,同一相(xiang)的(de)四個可(ke)控(kong)(kong)硅(gui)均(jun)顯示擊穿,此時(shi)應把該組可(ke)控(kong)(kong)硅(gui)間的(de)聯接銅排拆掉再(zai)測 。
十(shi)四訂貨須知
1、提供電(dian)(dian)機型號(hao)、額(e)定(ding)功率、定(ding)子(zi)電(dian)(dian)壓(ya)、定(ding)子(zi)電(dian)(dian)流、轉子(zi)電(dian)(dian)壓(ya)、轉子(zi)電(dian)(dian)流、額(e)定(ding)功率因(yin)數。
2、提供電機拖動負載(zai)的(de)特征及負載(zai)率。
預知(zhi)TP系列無環流靜止式進相器的更多信息,請(qing)撥打襄(xiang)陽拓邦電(dian)(dian)氣官網電(dian)(dian)話: 鄭(zheng)經理17771133316或咨(zi)詢網站(zhan)客服(fu)!!