TP系列無環流靜止式進相器是襄陽拓邦電(dian)(dian)(dian)(dian)氣(qi)自選研制(zhi)開發的(de)(de)新(xin)一代高(gao)新(xin)技術產(chan)品,是一種(zhong)專為大(da)中型繞線(xian)式異(yi)步電(dian)(dian)(dian)(dian)動機(ji)設計制(zhi)作的(de)(de)就地無(wu)功功率補償裝(zhuang)置(zhi)。它(ta)串接于電(dian)(dian)(dian)(dian)機(ji)轉(zhuan)(zhuan)子(zi)(zi)回路,改變轉(zhuan)(zhuan)子(zi)(zi)電(dian)(dian)(dian)(dian)流(liu)與轉(zhuan)(zhuan)子(zi)(zi)電(dian)(dian)(dian)(dian)壓的(de)(de)相位(wei)關系,通過磁場進而改變電(dian)(dian)(dian)(dian)機(ji)定(ding)子(zi)(zi)電(dian)(dian)(dian)(dian)流(liu)與電(dian)(dian)(dian)(dian)壓的(de)(de)相位(wei)關系,達到(dao)提(ti)高(gao)電(dian)(dian)(dian)(dian)機(ji)自身功率因(yin)數、降(jiang)低電(dian)(dian)(dian)(dian)機(ji)定(ding)子(zi)(zi)電(dian)(dian)(dian)(dian)流(liu)和(he)溫升的(de)(de)目的(de)(de)。這種(zhong)方式從根(gen)本(ben)(ben)上改善了(le)電(dian)(dian)(dian)(dian)機(ji)的(de)(de)運行狀(zhuang)況,顯(xian)著降(jiang)低電(dian)(dian)(dian)(dian)機(ji)及電(dian)(dian)(dian)(dian)網的(de)(de)無(wu)功損耗,對節能(neng)降(jiang)耗、降(jiang)低單位(wei)產(chan)品成(cheng)本(ben)(ben),提(ti)高(gao)企業(ye)的(de)(de)經(jing)濟(ji)效(xiao)益具(ju)有重要的(de)(de)意義(yi)。
TP系列無環(huan)流(liu)靜止式(shi)進相器對(dui)(dui)無功功率的(de)(de)(de)補償與電機定子側(ce)并(bing)聯電容(rong)器的(de)(de)(de)補償有著(zhu)本(ben)質的(de)(de)(de)區(qu)別。電容(rong)補償只(zhi)是在(zai)電機之外的(de)(de)(de)電網(wang)上對(dui)(dui)無功進行(xing)補償,減少電網(wang)的(de)(de)(de)無功輸(shu)入,電網(wang)的(de)(de)(de)功率因數得(de)到(dao)提高,但是電機的(de)(de)(de)無功消耗并(bing)沒(mei)有減少,無法改善電機本(ben)身(shen)的(de)(de)(de)運行(xing)狀況;而TP系列靜止式進相器是串接在(zai)電(dian)機轉(zhuan)子(zi)回路中(zhong),不僅可顯(xian)著提高功率因數(shu),使電(dian)機定(ding)子(zi)電(dian)流大(da)幅(fu)度降低,而且電(dian)機溫升明(ming)顯(xian)降低,電(dian)機的(de)效率和過載能力顯(xian)著提高。
TP系列靜止(zhi)式(shi)(shi)進(jin)相(xiang)(xiang)(xiang)器與自(zi)激(旋(xuan)轉)式(shi)(shi)進(jin)相(xiang)(xiang)(xiang)機(ji)(ji)(ji)也不同。TP系列靜止(zhi)式(shi)(shi)進(jin)相(xiang)(xiang)(xiang)器采用了(le) 的交-交變頻技(ji)術和微機(ji)(ji)(ji)、可控(kong)(kong)硅控(kong)(kong)制(zhi)技(ji)術,可自(zi)動跟蹤(zong)電機(ji)(ji)(ji)運(yun)行狀態的變化并自(zi)動調整相(xiang)(xiang)(xiang)關參數以達到(dao)佳的補償效(xiao)果,這是自(zi)激式(shi)(shi)進(jin)相(xiang)(xiang)(xiang)機(ji)(ji)(ji)無(wu)法做到(dao)的。而(er)且,TP系列靜止(zhi)式(shi)(shi)進(jin)相(xiang)(xiang)(xiang)器從根本上克服(fu)了(le)自(zi)激式(shi)(shi)進(jin)相(xiang)(xiang)(xiang)機(ji)(ji)(ji)“整流子”結構(gou)特別怕塵埃、壽(shou)命(ming)短、維修頻繁的缺點(dian);具有參數調節容易、主回路(lu)無(wu)轉動部(bu)件(jian)、不怕灰塵、可靠性高、使用壽(shou)命(ming)長、維護方便,是理想的取代(dai)自(zi)激式(shi)(shi)進(jin)相(xiang)(xiang)(xiang)機(ji)(ji)(ji)的新型(xing)高科(ke)技(ji)產品。
TP系列(lie)靜止式(shi)進相器可廣泛用于水泥、化工、礦山、冶金、鋼鐵、造紙(zhi)、制藥等行業的大(da)中型高低壓繞線式(shi)異步電機。
二型號(hao)命名
TP系列靜止式進相器型號命名方法如(ru)下:
型號:TP-800,表示適(shi)用(yong)于額(e)定(ding)轉子(zi)電流(liu)不超(chao)過(guo)800A的電機的靜止(zhi)式進相器。
三工作原理
當電機(ji)(ji)運行(xing)進(jin)(jin)(jin)相(xiang)時,進(jin)(jin)(jin)相(xiang)器通(tong)過轉子(zi)(zi)(zi)電流(liu)傳感器采(cai)集到的(de)(de)轉子(zi)(zi)(zi)電流(liu)信號(hao)及工頻(pin)(pin)電壓(ya)提(ti)供(gong)的(de)(de)同(tong)(tong)步信號(hao)經微處理器CPU進(jin)(jin)(jin)行(xing)數(shu)據和(he)相(xiang)位(wei)(wei)處理,控制可(ke)控硅的(de)(de)觸發信號(hao),調整由12只(zhi)晶閘(zha)管組成的(de)(de)交—交變(bian)(bian)頻(pin)(pin)裝置,將降壓(ya)后的(de)(de)工頻(pin)(pin)電源變(bian)(bian)為和(he)轉子(zi)(zi)(zi)電流(liu)同(tong)(tong)頻(pin)(pin)率(lv),相(xiang)位(wei)(wei)滯后90°的(de)(de)附加電勢加在電機(ji)(ji)轉子(zi)(zi)(zi)回(hui)路中(zhong)。轉子(zi)(zi)(zi)的(de)(de)電流(liu)和(he)電壓(ya)相(xiang)位(wei)(wei)因(yin)此改變(bian)(bian),通(tong)過磁場進(jin)(jin)(jin)而(er)改變(bian)(bian)電機(ji)(ji)定子(zi)(zi)(zi)電流(liu)與(yu)定子(zi)(zi)(zi)電壓(ya)的(de)(de)相(xiang)位(wei)(wei)角(jiao),使電機(ji)(ji)的(de)(de)功率(lv)因(yin)數(shu)提(ti)高,得到補(bu)償。
當電(dian)機在某一(yi)負載下運行(xing)時,其轉子電(dian)流(liu)為I2e、定子電(dian)流(liu)為I1e, 向(xiang)量圖如下所示(shi)。
從(cong)電機學我(wo)們知道(dao),激(ji)磁電流(liu)Im由(you)關系(xi)式Im=I1e-I2e,從(cong)向(xiang)量圖(tu)可得出Im。當進(jin)相器的(de)(de)(de)電勢疊加(jia)在轉子回路后,轉子電流(liu)的(de)(de)(de)相位(wei)變為圖(tu)中(zhong)的(de)(de)(de)I2。由(you)于負載(zai)不(bu)變,激(ji)磁電流(liu)Im不(bu)變。此時的(de)(de)(de)定子電流(liu)I1由(you)關系(xi)式I1=Im+I2從(cong)向(xiang)量圖(tu)可得出I1,如圖(tu)所示(shi)。從(cong)圖(tu)中(zhong)可以看出I1的(de)(de)(de)功(gong)率因數(shu)角(jiao)和(he)幅(fu)值都比I1e小(xiao),說明電機的(de)(de)(de)功(gong)率因數(shu)有(you)所提高(gao),定子電流(liu)有(you)所下降。
進(jin)相器就是這(zhe)樣(yang)改變轉子電流(liu)與轉子電壓的相位關系,通過磁場進(jin)而改變電機(ji)定(ding)子電流(liu)與定(ding)子電壓的相位關系,減小功率因數角(jiao),終(zhong)使電機(ji)本身的功率因數得(de)以(yi)提(ti)高,定(ding)子電流(liu)得(de)以(yi)下降,達(da)到對(dui)電機(ji)補償(chang)的目的。
當(dang)負載(zai)發生改變時(shi),微(wei)處理器實時(shi)檢測電機參數(shu)的(de)變化(hua)(hua),并(bing)根(gen)據(ju)負載(zai)的(de)變化(hua)(hua),動態調整附加在(zai)轉子上的(de)電勢(shi)幅值,以使電機的(de)功率(lv)因數(shu)始終保持(chi)在(zai)期望值上。
四原理框圖(tu)
電(dian)容式補(bu)償的(de)矢量(liang)分析:
電容補(bu)償(chang)和進相器補(bu)償(chang)的原(yuan)理圖分(fen)別如下:
圖中(zhong),將電(dian)(dian)機進(jin)行了等效(xiao)簡化,R1、X1為(wei)(wei)電(dian)(dian)機定子等效(xiao)電(dian)(dian)路的(de)電(dian)(dian)阻(zu)和電(dian)(dian)感(gan),R2、X2為(wei)(wei)電(dian)(dian)機轉子等效(xiao)電(dian)(dian)路的(de)電(dian)(dian)阻(zu)和電(dian)(dian)感(gan),C為(wei)(wei)就地(di)補償的(de)電(dian)(dian)容,Uf為(wei)(wei)進(jin)相(xiang)器的(de)等效(xiao)電(dian)(dian)路,M為(wei)(wei)電(dian)(dian)機的(de)接(jie)線點(dian)。
從圖可以看(kan)出,靜(jing)止(zhi)式進(jin)相器和(he)電容(rong)(rong)補(bu)償(chang)(chang)對電機的(de)作用點不同,電容(rong)(rong)是在電機的(de)前端定子側進(jin)行補(bu)償(chang)(chang),其補(bu)償(chang)(chang)范(fan)圍是在補(bu)償(chang)(chang)點的(de)前端;靜(jing)止(zhi)式進(jin)相器串聯在電機的(de)后(hou)端,其補(bu)償(chang)(chang)范(fan)圍擴大到了(le)電機。
五(wu)性能(neng)特點
1、可使電機的功率(lv)因數提高到0.95以上,無功功率(lv)降(jiang)低60%以上。
2、降低定子電流10%-20%。
3、降低線損、銅(tong)損20%-30%。
4、電(dian)機溫升降低5%。
5、過載能力和(he)效率大大提高,電機使用壽(shou)命(ming)延(yan)長。
6、具(ju)有故障自動保(bao)護功(gong)能,保(bao)障設備長期安全運行(xing)。
7、操作簡單,安(an)裝調試和維修保養均(jun)不影響正常生(sheng)產(chan),半年內可收回成本(ben)。
六使用條(tiao)件
1、安(an)裝(zhuang)地(di)點環(huan)境溫度≤40℃
2、安(an)裝地點相對濕(shi)度≤90%
3、 安裝地(di)點無火災、爆炸危險品,無化(hua)學(xue)腐蝕及劇烈振動。
4、海拔高度≤1500M。
5、進相器(qi)柜(ju)(ju)體(ti)(ti)上方(fang)0.5米(mi)(mi)內應通(tong)風;如無地溝,須將(jiang)進相器(qi)柜(ju)(ju)體(ti)(ti)架(jia)空0.1米(mi)(mi)。
注:TP系列(lie)靜止式進相器應滿足(zu)上方要求的使用條(tiao)件,襄陽拓邦電氣還(huan)可提供適用(yong)于高原地(di)區(海(hai)拔超過1500米)的靜止式進相器(但用(yong)戶須(xu)事先特別申請)。
七(qi)技術參數
進 相 器 型 號 |
適 配 電 機 參 數 |
|
額定轉子電流(A) |
額定功率(KW) |
|
TP-400 |
≤400 |
95-800 |
TP-500 |
400-500 |
245-1000 |
TP-600 |
500-600 |
315-1250 |
TP-800 |
600-800 |
630-1600 |
TP-1000 |
800-1000 |
1000-2000 |
TP-1200 |
1000-1200 |
1600-2500 |
TP-1500 |
1200-1500 |
2000以上 |
八(ba)安裝尺寸
1、外型(xing)尺寸圖
2、安裝基礎(chu)圖
3、規格尺寸(cun)表
型號(hao) |
外形尺寸(MM) |
安裝尺寸(MM) |
||||
寬(W) |
深(D) |
高(H) |
寬(E) |
深(F) |
螺孔 |
|
TP400-600 |
1000 |
760 |
2000 |
780 |
620 |
14 |
TP800-1000 |
1100 |
800 |
2000 |
880 |
650 |
14 |
TP1200-1500 |
1200 |
900 |
2200 |
980 |
750 |
16 |
注:隨(sui)著產品(pin)不斷(duan)更(geng)新(xin)換代,外形及安裝尺(chi)寸(cun)會有所變(bian)化(hua),請以具體的產品(pin)為準。
九安裝調試(shi)
(一)安裝
1、將(jiang)進(jin)相(xiang)器(qi)搬到(dao)安裝位置,注(zhu)意(yi)進(jin)相(xiang)器(qi)柜體底部應與(yu)地溝相(xiang)通或架(jia)空,首先是打開柜子(zi)的前后門,從上到(dao)下,逐一地擰(ning)緊螺(luo)絲,防止在運輸過(guo)程中螺(luo)絲松(song)動造成進(jin)相(xiang)器(qi)不能正常工作。
2、準備(bei)好連接(jie)(jie)【主(zhu)電(dian)(dian)機轉子至進(jin)(jin)相(xiang)器接(jie)(jie)觸器KM13的三(san)根電(dian)(dian)纜】、【進(jin)(jin)相(xiang)器接(jie)(jie)觸器KM11至主(zhu)電(dian)(dian)機起動柜(ju)的三(san)根電(dian)(dian)纜】,其線徑(jing)應(ying)能承(cheng)載主(zhu)電(dian)(dian)機轉子額定電(dian)(dian)流,比(bi)好長度(du)并壓好接(jie)(jie)頭。
3、進(jin)相器(qi)(qi)上(shang)(shang)的(de)電(dian)(dian)(dian)流(liu)表、功率因數表是直(zhi)接從電(dian)(dian)(dian)機定子(zi)(zi)回路(lu)上(shang)(shang)的(de)電(dian)(dian)(dian)流(liu)互(hu)(hu)感(gan)器(qi)(qi)、電(dian)(dian)(dian)壓(ya)(ya)(ya)互(hu)(hu)感(gan)器(qi)(qi)取信號,要(yao)求所用(yong)(yong)電(dian)(dian)(dian)流(liu)互(hu)(hu)感(gan)器(qi)(qi)副(fu)(fu)邊的(de)額(e)定電(dian)(dian)(dian)流(liu)為5A、電(dian)(dian)(dian)壓(ya)(ya)(ya)互(hu)(hu)感(gan)器(qi)(qi)副(fu)(fu)邊的(de)額(e)定電(dian)(dian)(dian)壓(ya)(ya)(ya)為100V,若用(yong)(yong)戶現用(yong)(yong)的(de)不滿(man)足該(gai)要(yao)求,則須另行(xing)準備符合上(shang)(shang)述要(yao)求的(de)互(hu)(hu)感(gan)器(qi)(qi)。(注(zhu):電(dian)(dian)(dian)壓(ya)(ya)(ya)互(hu)(hu)感(gan)器(qi)(qi)僅適(shi)用(yong)(yong)于高壓(ya)(ya)(ya)電(dian)(dian)(dian)機,對低壓(ya)(ya)(ya)電(dian)(dian)(dian)機,進(jin)相器(qi)(qi)電(dian)(dian)(dian)壓(ya)(ya)(ya)信號直(zhi)接從定子(zi)(zi)回路(lu)取)
4、新電機須帶(dai)上90%以(yi)上負載(zai)并正常運轉后才可調試(shi)進相器,用戶在(zai)通知(zhi)我方調試(shi)前,應調試(shi)好電機、減(jian)速機、磨機等(deng)其它設備,使其帶(dai)上負載(zai)正常運轉,以(yi)免延誤(wu)進相器調試(shi)時間(jian)。
5、各聯鎖(suo)線意義如下:
(225、227)取(qu)自(zi)電機(ji)(ji)起(qi)動(dong)柜星點(dian)短接(jie)接(jie)觸(chu)器(qi)的輔助(zhu)常(chang)開點(dian),只有在(zai)電機(ji)(ji)起(qi)動(dong)完畢后(hou),進相器(qi)才(cai)可以進相。
(355、357)當開(kai)關(guan)(guan)柜主開(kai)關(guan)(guan)是接觸器(qi)時(shi)與分閘按鈕(niu)并聯;是斷路(lu)器(qi)時(shi)與分閘按鈕(niu)串(chuan)聯, 進相狀態(tai)下主電機不能停機,只有(you)先退相才能停主機。
(359、361)串入開關柜合閘(zha)回路。當KM11吸(xi)合時,可以(yi)起動(dong)電機。
(363、369)從起動柜控制(zhi)(zhi)電(dian)源引單相380V,使(shi)KM11與起動柜控制(zhi)(zhi)回路(lu)同時(shi)得電(dian)。
(30、32)串(chuan)入主(zhu)電(dian)(dian)(dian)機(ji)電(dian)(dian)(dian)流計量回路;(40、42)并入主(zhu)電(dian)(dian)(dian)機(ji)電(dian)(dian)(dian)壓(ya)計量回路。(取A相(xiang)(xiang)電(dian)(dian)(dian)流則取B,C相(xiang)(xiang)電(dian)(dian)(dian)壓(ya),如此類推,電(dian)(dian)(dian)流和電(dian)(dian)(dian)壓(ya)不得(de)取同(tong)相(xiang)(xiang))。
(A、B、C、N)接三相四線電源,導線橫(heng)截面積(ji):TP600以下(xia)用(yong)4mm2;TP1000以下(xia)用(yong)6mm2;TP1500以下(xia)用(yong)10mm2。
6、控制器所(suo)有(you)指示燈(deng)的含義說明如(ru)下:
(1)主板(中間一塊)的指示(shi)燈(從上往下(xia)數)
●L1、L2、L3:電(dian)機轉子(zi)三相(xiang)電(dian)流(liu)信號指示(shi)(shi)(電(dian)機運(yun)轉時為循環(huan)顯示(shi)(shi)狀(zhuang)(zhuang)態;自檢試(shi)驗時為隨(sui)機狀(zhuang)(zhuang)態:或(huo)亮(liang)、或(huo)滅)
●L4:+5V電源(yuan)指示(shi)(保持亮的狀態)
●L5:熱故障(zhang)(zhang)指示(有熱故障(zhang)(zhang)時L5滅)
●L6:缺相及自動故障(zhang)保護指示(shi)(有缺相故障(zhang)及其它故障(zhang)時L6燈滅)
●L7:+15V電源指示(保持亮的狀(zhuang)態)
●L8:-15V電源指示(shi)(保持(chi)亮的狀態)
(2)驅動板(兩邊兩塊(kuai))
●分別代表12個可控制硅的(de)(de)觸發信號(指示燈均亮,并有(you)規律的(de)(de)閃(shan)爍)
(二)試(shi)驗(yan)
1、檢(jian)查主(zhu)電纜、聯鎖線(xian)(xian)、儀表(biao)線(xian)(xian)連(lian)接(jie)是否正確。
2、檢查各器(qi)件螺(luo)絲是(shi)否(fou)緊固。
3、用萬用表測量(liang)可(ke)控(kong)硅極(ji)間電阻:
●觸發(fa)極G與陰(yin)極K間電阻為幾(ji)十歐(ou)姆;
●觸發極G與陽極A間電阻大(da)于幾十千歐;
●陰極(ji)K與(yu)陽極(ji)A間電阻(zu)大(da)于(yu)幾十(shi)千歐;
●陰極K與陽極A用萬用表200K檔測量,阻值應從小變化到無限大。
4、合上(shang)起動柜電(dian)(dian)源,進相器(qi)背面的接觸器(qi)KM11應吸(xi)合,短接225、227;合上(shang)進相器(qi)電(dian)(dian)源,電(dian)(dian)源指示(shi)燈亮;控制器(qi)應有電(dian)(dian),控制器(qi)上(shang)指示(shi)燈亮。
5、控制器上(shang)撥碼開關打(da)在ON(上(shang)方)位置(zhi),中間(jian)主板(ban)L1、L2、L3循環亮(liang)或滅,L4~L8全亮(liang);兩(liang)邊兩(liang)塊驅(qu)動板(ban)指示燈閃爍。
6、按綠(lv)色進相(xiang)(xiang)按鈕,進相(xiang)(xiang)器(qi)前面的接(jie)觸器(qi)KM13吸合,延時后,背面的接(jie)觸器(qi)KM11斷開,綠(lv)色進相(xiang)(xiang)指示(shi)燈亮(liang),風機運轉(zhuan),風應向上(shang)吹,主變(bian)壓(ya)器(qi)副邊電流不(bu)超過30A,并且沒(mei)有大幅度變(bian)化(hua)。
7、按紅色退相(xiang)(xiang)按鈕(niu),進相(xiang)(xiang)器(qi)(qi)后面(mian)的接(jie)觸器(qi)(qi)KM11吸合,延(yan)時后,前面(mian)的接(jie)觸器(qi)(qi)KM13斷(duan)開,綠色進相(xiang)(xiang)指(zhi)示燈滅,紅色電源指(zhi)示燈亮(liang),進相(xiang)(xiang)器(qi)(qi)即退出進相(xiang)(xiang)狀(zhuang)態(tai)。
8、通電試(shi)驗結(jie)束,請務必斷(duan)開225、227。
(三(san))調試
1、運行前(qian):控(kong)制(zhi)器主(zhu)板上撥碼(ma)開關應(ying)打在OFF(下方)位(wei)置。
2、起動(dong)(dong)主(zhu)電機(ji):打開進相(xiang)器(qi)前柜(ju)門,合上(shang)空氣開關(guan),進相(xiang)器(qi)電源接通,面板上(shang)的紅色電源指(zhi)示(shi)燈亮,關(guan)閉柜(ju)門,等(deng)待主(zhu)機(ji)起動(dong)(dong)。
3、進相(xiang):(1)電(dian)(dian)機(ji)正常(chang)運轉(zhuan)后,按綠(lv)色進相(xiang)按鈕,進相(xiang)器(qi)(qi)前(qian)面的接觸(chu)器(qi)(qi)KM13吸合,延時后,背(bei)面的接觸(chu)器(qi)(qi)KM11斷(duan)開,綠(lv)色進相(xiang)指示燈亮,風(feng)機(ji)運轉(zhuan),定(ding)子(zi)電(dian)(dian)流(liu)應下(xia)(xia)降,功率因數應上升。如果(guo)定(ding)子(zi)電(dian)(dian)流(liu)不下(xia)(xia)降反而上升,調(diao)整同(tong)步(bu)變壓器(qi)(qi)上6V、6V0兩線的位(wei)置,再(zai)進相(xiang)。
(2)測量主(zhu)變壓器原、副邊(bian)電流,應(ying)無大幅(fu)度擺(bai)動。
(3)電(dian)機定子電(dian)流(liu)應平(ping)穩,無大幅度擺(bai)動。
(4)六個電抗器(qi)上端銅排的(de)電流擺動幅(fu)度應一致。
4、退相(xiang):按紅色退相(xiang)按鈕,進相(xiang)器(qi)后(hou)面的接觸(chu)器(qi)KM11吸合(he),延時后(hou),前面的接觸(chu)器(qi)KM13斷開,綠(lv)色進相(xiang)指示燈(deng)(deng)滅,紅色電源指示燈(deng)(deng)亮,進相(xiang)器(qi)即退出進相(xiang)狀(zhuang)態(tai)。
5、停車(che)(che):進(jin)相器退相后(hou),按下主機停車(che)(che)按鈕(niu),電機即停車(che)(che)。
(四)測量(liang)和觀察(cha)
1、測量可控(kong)硅、銅排、交流接觸器(qi)、電(dian)抗器(qi)、主變壓器(qi)、控(kong)制板溫度(du)。
2、測量(liang)可控硅觸發電(dian)壓(ya);主變壓(ya)器(qi)一次(ci)、二(er)次(ci)電(dian)流;電(dian)抗(kang)器(qi)輸入電(dian)流。
3、觀(guan)察風機運行(xing)情況。
4、觀察整體運行情況(kuang),有(you)無異常響(xiang)聲(sheng)或銅排有(you)無大的(de)抖動現象(xiang)等。
十使(shi)用維護
為確保TP系列靜止式進相器長(chang)期安全、可靠地(di)運行,請操(cao)作人員特別注意以下事(shi)項(xiang):
1、嚴禁在進(jin)相器(qi)運(yun)行期間(jian),切斷(duan)進(jin)相器(qi)外部(bu)電源(yuan)。
2、定(ding)期檢(jian)查冷(leng)卻風機運轉狀(zhuang)況,冷(leng)卻風機停轉使可(ke)控硅散熱(re)能(neng)力(li)下降,可(ke)能(neng)燒壞可(ke)控硅。
3、定期檢(jian)測主(zhu)變(bian)壓器(qi)原、副邊運(yun)行電(dian)流(liu)。
4、定(ding)期檢測可控硅、聯接銅(tong)排、交流接觸器、電(dian)抗器、主變(bian)壓(ya)器、控制板的溫度。
5、定(ding)(ding)期檢(jian)修(xiu)主回(hui)路(lu)接觸(chu)(chu)(chu)器的(de)觸(chu)(chu)(chu)頭。真空接觸(chu)(chu)(chu)器定(ding)(ding)期檢(jian)測(ce)絕緣電(dian)(dian)阻,用(yong)5KV或2.5KV搖表檢(jian)查,當開關管絕緣電(dian)(dian)阻小于100兆歐時,應加強監(jian)視,小于20兆歐時應立(li)即更換新管,以延長接觸(chu)(chu)(chu)器的(de)使用(yong)壽命(ming),保障(zhang)進(jin)相器及(ji)電(dian)(dian)機安全運行。
6、當進相器停用一段時(shi)間又重新啟(qi)用時(shi), 次進相前應觀察(cha)柜(ju)內(nei)控制單元上各指示燈是否正(zheng)常。電機起動并正(zheng)常運轉后(hou),各指示燈顯示如(ru)下(xia):
·主板(ban)(中間一塊):除L1,L2,L3周期性循環顯(xian)示外(注意:此(ci)指電機(ji)在運轉時的狀態,若電機(ji)未轉,該三燈為隨機(ji)狀態),其(qi)它各燈均亮。
·驅動扳(兩邊的兩塊):其上面各指示燈均亮(liang)并有輕微(wei)閃爍(shuo)。
7、當電(dian)機定(ding)子電(dian)流出(chu)現異常大(da)幅擺動(dong)時,應立即(ji)退相,查出(chu)原因并檢修后投入(ru)使用。
8、定期打掃柜內衛生。
十(shi)一故障處理(li)
主電機不能起動 |
端子363、369無380V 電源 |
檢查起(qi)動柜(ju)控制電源 |
||
|
接觸器KM11不吸合 |
檢查KM11線包及其控制回路 |
||
|
接觸器KM11吸合,但其輔助觸點未閉合 |
檢修(xiu)其輔助觸點 |
||
|
端子359、361串入合閘回路的線未接通 |
檢查該(gai)回路(lu) |
||
不能(neng)投(tou)入進相 |
空氣開關QF1、QF2、QF3沒合上 |
合(he)上空氣開關 |
||
|
按鈕STP、ST接觸不良 |
|
||
|
中間繼電器KA11觸點接觸不良 |
|
||
|
主電機起動柜內星點接觸器常開輔助觸點不能閉合(225、227未接通) |
檢修該(gai)接觸器輔助觸點及(ji)連線(xian) |
||
|
KM13不能吸合(he) |
檢查KM13線包及其控制回路 |
||
|
固態繼電器FV損壞或者不導通 |
控制器主控制板L6燈滅 |
檢查主控板7腳對11、12、13腳有無+、-3伏左右電壓,否則更換電流傳感器 |
|
|
|
檢查固態繼電器FV |
FV的3、4腳有直流15V電(dian)壓,而(er)323、325不(bu)通,須更換該繼電(dian)器 |
|
進相后主電機停機 |
接入開關柜的KM11、KM13的輔助觸點359、361接觸不好 |
維修該(gai)觸點 |
||
|
進相(xiang)器投入進相(xiang)瞬間外部空氣開(kai)關跳閘 |
更換大規格的空氣開關(guan) |
||
進(jin)相后無效果 |
接入主(zhu)控板的電流傳感(gan)器信號線錯誤 |
電流傳感器從左到右TA1、TA2、TA3的信號線應分別對應與主控板的13、12、11腳 |
||
|
主(zhu)控板的撥碼(ma)開關在自檢位 |
撥碼開關撥至工作位 |
||
|
KM13吸合后KM11未釋放(時(shi)間繼電器KT11壞) |
更換KT11時間繼電器 |
||
|
KM15沒有(you)吸合 |
KM11的輔助觸點301、305接觸不良 |
維修(xiu)該(gai)觸點 |
|
|
|
KM15線(xian)圈故障 |
更換KM15線圈 |
|
|
KM15主觸點接觸不良 |
更換KM15 |
||
|
主(zhu)變壓器原邊開(kai)路 |
更換(huan)主變壓器 |
||
進(jin)相后主電機電流不減反(fan)增 |
同步電源相序(xu)錯誤(wu) |
調換進相器內小變壓器TC上輸出6V、6V0電壓的兩線位置 |
||
|
電機轉速下降(缺相(xiang)),自動退(tui)相(xiang) |
KM13主觸點接觸不良 |
維修該觸點 |
|
|
|
電(dian)機(ji)轉子線松動,進(jin)相時(shi)的電(dian)流沖擊導致缺相 |
檢(jian)查電機轉子線 |
|
進相后(hou)主(zhu)電機電流擺動大 |
可(ke)控硅擊穿 |
測量可(ke)控硅極間電阻(詳(xiang)細(xi)方法見(jian)調試(shi)部分) |
||
|
觸發(fa)板損壞 |
測量可控硅控制極與陰極之間應有0.2V以上的直流電壓信號,否則應檢查觸發板 |
||
|
主(zhu)板的(de)撥碼開(kai)關在自檢位 |
撥碼(ma)開關(guan)撥至工作(zuo)位 |
||
|
電機(ji)轉子(zi)線松(song)動 |
檢查電機轉(zhuan)子(zi)線 |
||
|
當KM13采用節能型線圈時,線圈故障導致KM13進行瞬間來回釋放、吸合,導致主回路接觸不良 |
維修或更換KM13線圈 |
注意:進相器檢修不得在(zai)進(jin)相狀(zhuang)態(tai)下進(jin)行,發現(xian)問題應立(li)即退(tui)相。
十二(er)控制板檢修
現(xian)象 |
原因 |
對策 |
L1、L2、L3不循環閃爍,L6滅,其它各燈正常 |
轉子缺相 |
檢查接觸器KM2主觸頭是否損壞,若損壞,則維修觸頭或更換接觸器 |
電(dian)流傳感器器損壞(huai) |
檢查電流傳感器是否有±2V以上的輸出信號,否則更換傳感器 |
|
主控板元器件損壞 |
依次更換IC210、IC211 |
|
L1、L2、L3不周期性閃爍,其它各燈正常 |
主控板元器件損(sun)壞 |
依次更換IC210、IC211、IC205、IC207 |
L6滅,其它各燈正常 |
主(zhu)控(kong)板元器件損壞 |
依次更換IC207、IC209 |
L5滅,其它各燈正常 |
散熱器(qi)溫度檢測回路故障 |
檢(jian)查(cha)溫度開關及(ji)其連線 |
L4、L7、L8全部或部分滅 |
電源(yuan)故障 |
1、檢查變壓器及控制板是否有±18V電源 2、更換相應的7805、7815、7915 |
F1-L1~L6 或F2-L1~L6部分指示燈亮,主板各燈正常 |
觸發(fa)板元器件損壞 |
1、有一片ULN2004損壞,更換之 2、脈沖變壓器接觸不良,作相應處理 |
F1-L1~L6 或F2-L1~L6指示燈全滅,主板各燈正常 |
觸發板元器件損壞(huai) |
1、兩片ULN2004損壞,更換之 2、更換555芯片 |
觸發板無電源 |
1、檢查主板7815是否有虛焊 2、檢查觸發板19腳與主板6腳連接是否正常 |
十(shi)三(san)注意事(shi)項
1、進相器(qi)檢修應(ying)在(zai)退相狀(zhuang)態下進行,發現問題應(ying)立(li)即退相。
2、嚴禁隨意帶電插拔控制板,檢修控制板時,一(yi)定要(yao)把空開QF3打下來(lai)。
3、更換可控硅(gui)(gui)時(shi)(shi)應注意陰、陽極(ji)的方(fang)向,并(bing)壓(ya)緊(jin)散熱(re)器(壓(ya)力不要過大(da)),裝上后(hou)擰緊(jin)所有螺絲,之后(hou)再檢測可控硅(gui)(gui)各(ge)極(ji)間(jian)的電阻情況(kuang)。若(ruo)一只可控硅(gui)(gui)擊穿在(zai)柜體上直接(jie)檢測,同一相的四個可控硅(gui)(gui)均(jun)顯示擊穿,此(ci)時(shi)(shi)應把該組可控硅(gui)(gui)間(jian)的聯接(jie)銅(tong)排拆(chai)掉再測 。
十(shi)四訂貨須知
1、提供電(dian)(dian)機(ji)型號(hao)、額(e)定功率、定子(zi)電(dian)(dian)壓(ya)、定子(zi)電(dian)(dian)流(liu)、轉(zhuan)子(zi)電(dian)(dian)壓(ya)、轉(zhuan)子(zi)電(dian)(dian)流(liu)、額(e)定功率因數。
2、提供電機拖(tuo)動負(fu)載的特征及負(fu)載率。
預(yu)知TP系列無環流靜止式進相器的(de)更多信息,請撥(bo)打襄陽拓邦電氣官(guan)網(wang)(wang)電話: 鄭經理17771133316或咨詢(xun)網(wang)(wang)站客(ke)服(fu)!!