滕州TP系列靜止式進相器

一概(gai)述TP系列(lie)無環(huan)流靜止式(shi)進相器是襄陽拓邦電(dian)氣自選研制(zhi)開發的新一代(dai)高新技術產品,是一種(zhong)專(zhuan)為大中(zhong)型繞線式(shi)異……

相關內容
在線留言
詳情內容
content details

TP系列無環流靜止式進相器是襄(xiang)陽拓(tuo)邦電(dian)(dian)(dian)氣(qi)自(zi)選(xuan)研制開發的(de)(de)(de)(de)(de)新一(yi)代高(gao)(gao)新技術(shu)產品,是一(yi)種(zhong)專為大中型繞線式異(yi)步電(dian)(dian)(dian)動(dong)機(ji)設計制作的(de)(de)(de)(de)(de)就(jiu)地(di)無功(gong)功(gong)率(lv)補償裝(zhuang)置(zhi)。它串(chuan)接于(yu)電(dian)(dian)(dian)機(ji)轉子(zi)(zi)回路,改變轉子(zi)(zi)電(dian)(dian)(dian)流與(yu)轉子(zi)(zi)電(dian)(dian)(dian)壓(ya)的(de)(de)(de)(de)(de)相位關系,通過磁場(chang)進而改變電(dian)(dian)(dian)機(ji)定(ding)子(zi)(zi)電(dian)(dian)(dian)流與(yu)電(dian)(dian)(dian)壓(ya)的(de)(de)(de)(de)(de)相位關系,達到提高(gao)(gao)電(dian)(dian)(dian)機(ji)自(zi)身功(gong)率(lv)因數、降(jiang)低電(dian)(dian)(dian)機(ji)定(ding)子(zi)(zi)電(dian)(dian)(dian)流和(he)溫(wen)升的(de)(de)(de)(de)(de)目(mu)的(de)(de)(de)(de)(de)。這種(zhong)方式從(cong)根本上(shang)改善了電(dian)(dian)(dian)機(ji)的(de)(de)(de)(de)(de)運行狀況(kuang),顯著(zhu)降(jiang)低電(dian)(dian)(dian)機(ji)及電(dian)(dian)(dian)網的(de)(de)(de)(de)(de)無功(gong)損(sun)耗(hao),對(dui)節能降(jiang)耗(hao)、降(jiang)低單位產品成(cheng)本,提高(gao)(gao)企業的(de)(de)(de)(de)(de)經(jing)濟效(xiao)益(yi)具有重(zhong)要的(de)(de)(de)(de)(de)意義(yi)。


TP系列無(wu)(wu)環流靜止式進相(xiang)器(qi)對(dui)無(wu)(wu)功(gong)功(gong)率(lv)的(de)補償(chang)與電(dian)機定子側并(bing)(bing)聯電(dian)容器(qi)的(de)補償(chang)有著本(ben)質的(de)區(qu)別(bie)。電(dian)容補償(chang)只是(shi)在電(dian)機之外的(de)電(dian)網(wang)上對(dui)無(wu)(wu)功(gong)進行(xing)補償(chang),減少(shao)電(dian)網(wang)的(de)無(wu)(wu)功(gong)輸(shu)入(ru),電(dian)網(wang)的(de)功(gong)率(lv)因數得到提高,但是(shi)電(dian)機的(de)無(wu)(wu)功(gong)消耗并(bing)(bing)沒有減少(shao),無(wu)(wu)法(fa)改善電(dian)機本(ben)身的(de)運行(xing)狀況;而TP系列靜止式進相器是串接在電(dian)(dian)機(ji)(ji)轉子(zi)回(hui)路中,不僅可(ke)顯著提高功率(lv)因數,使(shi)電(dian)(dian)機(ji)(ji)定子(zi)電(dian)(dian)流大(da)幅度降低,而且電(dian)(dian)機(ji)(ji)溫(wen)升(sheng)明顯降低,電(dian)(dian)機(ji)(ji)的效率(lv)和過載能力(li)顯著提高。

TP系(xi)列(lie)靜(jing)(jing)(jing)止(zhi)式(shi)(shi)(shi)(shi)進(jin)(jin)(jin)相(xiang)(xiang)器與自(zi)激(ji)(ji)(ji)(ji)(旋轉(zhuan)(zhuan))式(shi)(shi)(shi)(shi)進(jin)(jin)(jin)相(xiang)(xiang)機(ji)(ji)(ji)(ji)也不同。TP系(xi)列(lie)靜(jing)(jing)(jing)止(zhi)式(shi)(shi)(shi)(shi)進(jin)(jin)(jin)相(xiang)(xiang)器采用了(le) 的交-交變頻(pin)(pin)技(ji)術和微機(ji)(ji)(ji)(ji)、可(ke)控(kong)硅控(kong)制技(ji)術,可(ke)自(zi)動跟(gen)蹤(zong)電機(ji)(ji)(ji)(ji)運(yun)行(xing)狀態的變化并自(zi)動調整(zheng)相(xiang)(xiang)關參數(shu)以達到(dao)佳的補償效果,這(zhe)是(shi)(shi)自(zi)激(ji)(ji)(ji)(ji)式(shi)(shi)(shi)(shi)進(jin)(jin)(jin)相(xiang)(xiang)機(ji)(ji)(ji)(ji)無(wu)(wu)法(fa)做到(dao)的。而且(qie),TP系(xi)列(lie)靜(jing)(jing)(jing)止(zhi)式(shi)(shi)(shi)(shi)進(jin)(jin)(jin)相(xiang)(xiang)器從根本上克服了(le)自(zi)激(ji)(ji)(ji)(ji)式(shi)(shi)(shi)(shi)進(jin)(jin)(jin)相(xiang)(xiang)機(ji)(ji)(ji)(ji)“整(zheng)流(liu)子”結構特別怕(pa)塵埃、壽命短、維修頻(pin)(pin)繁的缺點;具有(you)參數(shu)調節(jie)容易、主(zhu)回路(lu)無(wu)(wu)轉(zhuan)(zhuan)動部件、不怕(pa)灰(hui)塵、可(ke)靠性(xing)高、使(shi)用壽命長(chang)、維護方便,是(shi)(shi)理想的取代自(zi)激(ji)(ji)(ji)(ji)式(shi)(shi)(shi)(shi)進(jin)(jin)(jin)相(xiang)(xiang)機(ji)(ji)(ji)(ji)的新型高科技(ji)產品。

TP系列(lie)靜止式進相(xiang)器(qi)可廣泛用于水泥、化(hua)工、礦山、冶金(jin)、鋼鐵、造紙、制藥等行業的(de)大中型高低壓繞線式異步(bu)電機。


二型號(hao)命名

TP系列靜止式進相器型號命(ming)名(ming)方法如下:





型號:TP-800,表示適用于額定轉子電流不超過(guo)800A的(de)(de)電機的(de)(de)靜止式進相器。


三工作原(yuan)理(li)

當電(dian)(dian)機(ji)運行(xing)進(jin)相時,進(jin)相器(qi)通過(guo)(guo)轉子(zi)電(dian)(dian)流(liu)(liu)傳感器(qi)采集到的(de)(de)(de)(de)(de)轉子(zi)電(dian)(dian)流(liu)(liu)信號及(ji)工(gong)頻電(dian)(dian)壓提供的(de)(de)(de)(de)(de)同步信號經(jing)微處(chu)理器(qi)CPU進(jin)行(xing)數據(ju)和(he)相位(wei)處(chu)理,控制可(ke)控硅的(de)(de)(de)(de)(de)觸發(fa)信號,調整由(you)12只(zhi)晶閘管組(zu)成的(de)(de)(de)(de)(de)交(jiao)—交(jiao)變(bian)(bian)(bian)頻裝置(zhi),將(jiang)降(jiang)壓后的(de)(de)(de)(de)(de)工(gong)頻電(dian)(dian)源變(bian)(bian)(bian)為和(he)轉子(zi)電(dian)(dian)流(liu)(liu)同頻率,相位(wei)滯后90°的(de)(de)(de)(de)(de)附加電(dian)(dian)勢(shi)加在電(dian)(dian)機(ji)轉子(zi)回路(lu)中(zhong)。轉子(zi)的(de)(de)(de)(de)(de)電(dian)(dian)流(liu)(liu)和(he)電(dian)(dian)壓相位(wei)因此改變(bian)(bian)(bian),通過(guo)(guo)磁場進(jin)而改變(bian)(bian)(bian)電(dian)(dian)機(ji)定(ding)子(zi)電(dian)(dian)流(liu)(liu)與定(ding)子(zi)電(dian)(dian)壓的(de)(de)(de)(de)(de)相位(wei)角,使電(dian)(dian)機(ji)的(de)(de)(de)(de)(de)功(gong)率因數提高,得到補償。

當(dang)電機在某(mou)一負載下運(yun)行時,其轉子電流(liu)為I2e、定子電流(liu)為I1e, 向量圖如下所(suo)示。







從電(dian)(dian)機(ji)學我(wo)們知道,激(ji)(ji)磁電(dian)(dian)流Im由關系式Im=I1e-I2e,從向量圖(tu)可(ke)得(de)出(chu)Im。當進相器的(de)電(dian)(dian)勢疊加(jia)在轉子回路后,轉子電(dian)(dian)流的(de)相位變(bian)為圖(tu)中(zhong)的(de)I2。由于負(fu)載不(bu)(bu)變(bian),激(ji)(ji)磁電(dian)(dian)流Im不(bu)(bu)變(bian)。此(ci)時的(de)定子電(dian)(dian)流I1由關系式I1=Im+I2從向量圖(tu)可(ke)得(de)出(chu)I1,如圖(tu)所(suo)示。從圖(tu)中(zhong)可(ke)以看出(chu)I1的(de)功率因(yin)數角和幅(fu)值都比I1e小,說明電(dian)(dian)機(ji)的(de)功率因(yin)數有(you)所(suo)提高,定子電(dian)(dian)流有(you)所(suo)下降。

進相(xiang)器(qi)就是這(zhe)樣改變轉子電(dian)流(liu)與(yu)轉子電(dian)壓的(de)(de)相(xiang)位(wei)關(guan)系,通過磁場進而改變電(dian)機定子電(dian)流(liu)與(yu)定子電(dian)壓的(de)(de)相(xiang)位(wei)關(guan)系,減小功率因數角,終使電(dian)機本(ben)身的(de)(de)功率因數得以(yi)提高,定子電(dian)流(liu)得以(yi)下降,達(da)到對電(dian)機補償的(de)(de)目的(de)(de)。

當負載發(fa)生改變時,微處(chu)理(li)器實時檢測(ce)電(dian)機參(can)數的(de)變化(hua),并根據負載的(de)變化(hua),動態調整附加在轉子上的(de)電(dian)勢幅值,以(yi)使電(dian)機的(de)功(gong)率因(yin)數始終保持在期望值上。

四原理框圖(tu)






電容式補償的矢量分析:








電容補(bu)償和(he)進相器補(bu)償的原理圖分(fen)別如下:






圖(tu)中,將電(dian)(dian)(dian)(dian)機進(jin)行(xing)了等效(xiao)簡化,R1、X1為(wei)(wei)電(dian)(dian)(dian)(dian)機定子等效(xiao)電(dian)(dian)(dian)(dian)路(lu)的(de)電(dian)(dian)(dian)(dian)阻(zu)和(he)電(dian)(dian)(dian)(dian)感,R2、X2為(wei)(wei)電(dian)(dian)(dian)(dian)機轉子等效(xiao)電(dian)(dian)(dian)(dian)路(lu)的(de)電(dian)(dian)(dian)(dian)阻(zu)和(he)電(dian)(dian)(dian)(dian)感,C為(wei)(wei)就地(di)補償的(de)電(dian)(dian)(dian)(dian)容,Uf為(wei)(wei)進(jin)相器的(de)等效(xiao)電(dian)(dian)(dian)(dian)路(lu),M為(wei)(wei)電(dian)(dian)(dian)(dian)機的(de)接線點。

從圖可以看出(chu),靜(jing)止(zhi)(zhi)式進相器(qi)(qi)和電(dian)容補(bu)償對電(dian)機(ji)的作用點不同,電(dian)容是在(zai)電(dian)機(ji)的前(qian)端定(ding)子側進行補(bu)償,其(qi)補(bu)償范圍是在(zai)補(bu)償點的前(qian)端;靜(jing)止(zhi)(zhi)式進相器(qi)(qi)串聯在(zai)電(dian)機(ji)的后端,其(qi)補(bu)償范圍擴大到了電(dian)機(ji)。

五性能特點

1、可使電(dian)機的功率(lv)因數(shu)提高到(dao)0.95以上,無功功率(lv)降低(di)60%以上。

2、降低定子電(dian)流10%-20%。

3、降(jiang)低線損、銅損20%-30%。

4、電機溫(wen)升降低5%。

5、過載(zai)能力和效率大大提高(gao),電機使(shi)用壽命(ming)延長。

6、具有故障自動保護功能,保障設(she)備長期安全運(yun)行(xing)。

7、操作簡單,安(an)裝(zhuang)調(diao)試和維修保養均不影響(xiang)正常(chang)生產(chan),半(ban)年內可(ke)收(shou)回成(cheng)本。

六使用條(tiao)件

1、安裝地點環境溫度≤40℃

2、安裝(zhuang)地點相對濕(shi)度≤90%

3、 安裝(zhuang)地(di)點(dian)無火災、爆炸危險品,無化學腐蝕及劇烈振(zhen)動。

4、海拔高(gao)度≤1500M。

5、進(jin)相(xiang)器(qi)柜體上方0.5米內應通風(feng);如無地溝(gou),須將進(jin)相(xiang)器(qi)柜體架空(kong)0.1米。

注:TP系(xi)列靜止式(shi)進相器(qi)應(ying)滿(man)足上方(fang)要求(qiu)的使(shi)用條件(jian),襄陽拓邦電氣還可提供適用于高原地(di)區(海拔超(chao)過1500米)的靜止式進相器(但用戶須事先特別申(shen)請)。

七技術參數


相 器 型 號

配 電 機 參 數

額定轉子電流(A

額定功率(KW

TP-400

400

95-800

TP-500

400-500

245-1000

TP-600

500-600

315-1250

TP-800

600-800

630-1600

TP-1000

800-1000

1000-2000

TP-1200

1000-1200

1600-2500

TP-1500

1200-1500

2000以上




八安裝(zhuang)尺寸(cun)

1、外(wai)型尺寸圖






2、安裝基(ji)礎(chu)圖(tu)







3、規(gui)格尺寸表



型號

外形尺寸(MM)

安裝尺寸(MM)

(W)

(D)

(H)

(E)

(F)

螺孔(kong)

TP400-600

1000

760

2000

780

620

14

TP800-1000

1100

800

2000

880

650

14

TP1200-1500

1200

900

2200

980

750

16



注:隨著(zhu)產(chan)品(pin)不斷更新換代,外(wai)形(xing)及安(an)裝尺寸會(hui)有所變化,請以具體的產(chan)品(pin)為準。

九安裝(zhuang)調試

(一)安裝

1、將進相器(qi)(qi)搬到安裝位置(zhi),注意進相器(qi)(qi)柜(ju)體(ti)底部應與地溝相通或(huo)架空,首先是打開柜(ju)子(zi)的前后門,從上到下,逐一地擰(ning)緊(jin)螺(luo)絲(si)(si),防止在運輸過程中(zhong)螺(luo)絲(si)(si)松動造成進相器(qi)(qi)不能正常工作。

2、準備好(hao)連接(jie)【主電機(ji)轉(zhuan)子(zi)至進相(xiang)器接(jie)觸器KM13的三根電纜】、【進相(xiang)器接(jie)觸器KM11至主電機(ji)起動柜的三根電纜】,其線(xian)徑應(ying)能(neng)承載主電機(ji)轉(zhuan)子(zi)額定(ding)電流,比好(hao)長度并壓好(hao)接(jie)頭。

3、進相(xiang)器(qi)(qi)(qi)上(shang)(shang)的(de)(de)電(dian)(dian)(dian)(dian)流表、功率因數表是(shi)直接(jie)從(cong)電(dian)(dian)(dian)(dian)機(ji)定(ding)(ding)(ding)子回(hui)(hui)路上(shang)(shang)的(de)(de)電(dian)(dian)(dian)(dian)流互感(gan)(gan)(gan)器(qi)(qi)(qi)、電(dian)(dian)(dian)(dian)壓(ya)(ya)互感(gan)(gan)(gan)器(qi)(qi)(qi)取信(xin)號,要(yao)(yao)求所用(yong)電(dian)(dian)(dian)(dian)流互感(gan)(gan)(gan)器(qi)(qi)(qi)副邊的(de)(de)額定(ding)(ding)(ding)電(dian)(dian)(dian)(dian)流為5A、電(dian)(dian)(dian)(dian)壓(ya)(ya)互感(gan)(gan)(gan)器(qi)(qi)(qi)副邊的(de)(de)額定(ding)(ding)(ding)電(dian)(dian)(dian)(dian)壓(ya)(ya)為100V,若(ruo)用(yong)戶(hu)現(xian)用(yong)的(de)(de)不滿足該要(yao)(yao)求,則須另行準備符(fu)合(he)上(shang)(shang)述(shu)要(yao)(yao)求的(de)(de)互感(gan)(gan)(gan)器(qi)(qi)(qi)。(注:電(dian)(dian)(dian)(dian)壓(ya)(ya)互感(gan)(gan)(gan)器(qi)(qi)(qi)僅適用(yong)于高壓(ya)(ya)電(dian)(dian)(dian)(dian)機(ji),對低壓(ya)(ya)電(dian)(dian)(dian)(dian)機(ji),進相(xiang)器(qi)(qi)(qi)電(dian)(dian)(dian)(dian)壓(ya)(ya)信(xin)號直接(jie)從(cong)定(ding)(ding)(ding)子回(hui)(hui)路取)

4、新電機(ji)須帶上(shang)90%以(yi)上(shang)負載并正(zheng)常(chang)運(yun)轉后才可調試進相器(qi),用戶在通(tong)知(zhi)我方調試前,應調試好電機(ji)、減速(su)機(ji)、磨機(ji)等其它設備(bei),使其帶上(shang)負載正(zheng)常(chang)運(yun)轉,以(yi)免延誤進相器(qi)調試時間。

5、各聯鎖線意義如(ru)下:

(225、227)取自(zi)電(dian)機起動柜星點短接接觸器(qi)的輔助常開點,只有在電(dian)機起動完畢(bi)后,進相器(qi)才可以進相。

(355、357)當開關柜主開關是接觸器時與分閘(zha)按鈕并聯(lian)(lian);是斷(duan)路(lu)器時與分閘(zha)按鈕串聯(lian)(lian), 進相(xiang)狀態下(xia)主電機不能(neng)停(ting)機,只有先退(tui)相(xiang)才(cai)能(neng)停(ting)主機。

(359、361)串入開關(guan)柜合(he)閘回路。當(dang)KM11吸合(he)時,可(ke)以起(qi)動電(dian)機。

(363、369)從起動(dong)柜(ju)控(kong)制電源引單相380V,使KM11與起動(dong)柜(ju)控(kong)制回路同時得(de)電。

(30、32)串入(ru)主電(dian)機電(dian)流(liu)計(ji)量回(hui)路;(40、42)并入(ru)主電(dian)機電(dian)壓(ya)計(ji)量回(hui)路。(取(qu)A相電(dian)流(liu)則(ze)取(qu)B,C相電(dian)壓(ya),如此(ci)類推,電(dian)流(liu)和電(dian)壓(ya)不得取(qu)同相)。

(A、B、C、N)接(jie)三(san)相四線電源,導線橫(heng)截面積(ji):TP600以下用4mm2;TP1000以下用6mm2;TP1500以下用10mm2。

6、控(kong)制(zhi)器所有指示(shi)燈的含義(yi)說明(ming)如(ru)下:

(1)主板(ban)(中間一塊)的指示燈(從上(shang)往下(xia)數)

●L1、L2、L3:電機轉(zhuan)子(zi)三相(xiang)電流信號指(zhi)示(電機運轉(zhuan)時為循環顯示狀(zhuang)態;自檢試驗時為隨機狀(zhuang)態:或(huo)亮、或(huo)滅(mie))

●L4:+5V電(dian)源(yuan)指示(保持亮的狀態(tai))

●L5:熱故障指示(有熱故障時L5滅)

●L6:缺相及自(zi)動故(gu)障(zhang)保(bao)護(hu)指示(有缺相故(gu)障(zhang)及其它故(gu)障(zhang)時(shi)L6燈滅)

●L7:+15V電源指示(shi)(保持(chi)亮的狀態)

●L8:-15V電源指示(保持亮的狀態)

(2)驅(qu)動(dong)板(兩邊兩塊(kuai))

●分(fen)別代表12個可控制硅的觸(chu)發信號(指(zhi)示(shi)燈均亮,并有規律的閃爍)

(二)試驗

1、檢查主電纜、聯鎖線、儀表線連接是(shi)否正確。

2、檢(jian)查各器件螺絲是否緊(jin)固。

3、用(yong)萬用(yong)表測量可(ke)控(kong)硅極(ji)間電阻:

●觸(chu)發極G與陰極K間電阻為幾十歐(ou)姆;

●觸(chu)發極(ji)G與陽極(ji)A間電阻大于幾(ji)十千歐;

●陰極(ji)K與陽極(ji)A間電阻大于(yu)幾十千歐;

●陰極(ji)K與陽極(ji)A用萬(wan)用表(biao)200K檔測(ce)量,阻值應從小變化到(dao)無限大。

4、合上起動柜電(dian)(dian)源,進(jin)相器背面的接觸(chu)器KM11應吸合,短接225、227;合上進(jin)相器電(dian)(dian)源,電(dian)(dian)源指示燈(deng)亮;控制(zhi)(zhi)器應有(you)電(dian)(dian),控制(zhi)(zhi)器上指示燈(deng)亮。

5、控制器(qi)上(shang)撥(bo)碼開關打在ON(上(shang)方)位置,中間主(zhu)板L1、L2、L3循(xun)環(huan)亮或滅,L4~L8全亮;兩邊兩塊驅動板指示(shi)燈閃(shan)爍。

6、按綠(lv)色進(jin)相(xiang)按鈕,進(jin)相(xiang)器(qi)前(qian)面的接觸器(qi)KM13吸合,延時后,背面的接觸器(qi)KM11斷(duan)開(kai),綠(lv)色進(jin)相(xiang)指(zhi)示燈亮,風機(ji)運(yun)轉(zhuan),風應向上吹,主變(bian)壓(ya)器(qi)副邊電流不(bu)超(chao)過30A,并且沒有(you)大幅(fu)度變(bian)化。

7、按紅(hong)色退(tui)相按鈕(niu),進(jin)相器(qi)后(hou)面的接觸器(qi)KM11吸合,延時后(hou),前(qian)面的接觸器(qi)KM13斷(duan)開,綠色進(jin)相指示燈(deng)滅,紅(hong)色電源(yuan)指示燈(deng)亮,進(jin)相器(qi)即退(tui)出進(jin)相狀態。

8、通電試(shi)驗結束,請(qing)務必斷(duan)開225、227。

(三)調試(shi)

1、運行前:控(kong)制器(qi)主板(ban)上撥碼開關應打在OFF(下方)位置。

2、起(qi)動(dong)主電機:打開進(jin)相器(qi)前柜門(men),合上(shang)(shang)空氣開關,進(jin)相器(qi)電源接通,面板上(shang)(shang)的(de)紅色電源指(zhi)示燈亮(liang),關閉柜門(men),等待主機起(qi)動(dong)。

3、進(jin)相:(1)電(dian)機正常運(yun)轉(zhuan)后,按(an)綠色進(jin)相按(an)鈕,進(jin)相器(qi)(qi)前(qian)面的接觸(chu)器(qi)(qi)KM13吸合,延時后,背面的接觸(chu)器(qi)(qi)KM11斷開(kai),綠色進(jin)相指示燈亮(liang),風機運(yun)轉(zhuan),定(ding)子電(dian)流應下(xia)(xia)降,功率因數應上升(sheng)(sheng)。如果定(ding)子電(dian)流不下(xia)(xia)降反而上升(sheng)(sheng),調整同(tong)步(bu)變壓器(qi)(qi)上6V、6V0兩(liang)線的位置,再進(jin)相。

(2)測(ce)量主變(bian)壓器原(yuan)、副邊電流,應(ying)無大幅度擺動。

(3)電(dian)機定子(zi)電(dian)流應(ying)平(ping)穩,無大幅度(du)擺動(dong)。

(4)六(liu)個電抗器上端銅(tong)排的(de)電流擺(bai)動幅度應一(yi)致。

4、退(tui)(tui)相(xiang)(xiang)(xiang):按紅色(se)退(tui)(tui)相(xiang)(xiang)(xiang)按鈕,進(jin)相(xiang)(xiang)(xiang)器后(hou)(hou)面的(de)接觸器KM11吸合,延時后(hou)(hou),前面的(de)接觸器KM13斷(duan)開(kai),綠色(se)進(jin)相(xiang)(xiang)(xiang)指示(shi)燈(deng)滅,紅色(se)電(dian)源指示(shi)燈(deng)亮,進(jin)相(xiang)(xiang)(xiang)器即退(tui)(tui)出進(jin)相(xiang)(xiang)(xiang)狀態。

5、停(ting)車:進相器退相后(hou),按下主機停(ting)車按鈕,電機即(ji)停(ting)車。

(四(si))測量(liang)和觀察

1、測(ce)量可控(kong)硅、銅排(pai)、交流(liu)接觸器、電抗器、主變壓(ya)器、控(kong)制板(ban)溫度。

2、測(ce)量可控硅(gui)觸發電(dian)壓;主變壓器(qi)一次(ci)、二(er)次(ci)電(dian)流;電(dian)抗器(qi)輸(shu)入電(dian)流。

3、觀察風機(ji)運行情(qing)況。

4、觀察整體(ti)運行情況(kuang),有(you)無異常(chang)響聲或(huo)銅排有(you)無大的(de)抖(dou)動現(xian)象等。

十使用維護

為(wei)確保TP系列靜止式進相器長期安(an)全(quan)、可(ke)靠地運行,請操(cao)作人員特別注(zhu)意(yi)以下(xia)事項(xiang):

1、嚴(yan)禁在(zai)進(jin)相器運行(xing)期(qi)間(jian),切斷(duan)進(jin)相器外部電源(yuan)。

2、定期檢查冷卻風機(ji)運轉(zhuan)狀況(kuang),冷卻風機(ji)停(ting)轉(zhuan)使(shi)可控(kong)硅(gui)散熱能(neng)力下降,可能(neng)燒壞可控(kong)硅(gui)。

3、定期檢測主(zhu)變壓(ya)器原(yuan)、副(fu)邊(bian)運行電流。

4、定期檢測(ce)可控硅、聯接(jie)銅排、交流(liu)接(jie)觸器(qi)、電(dian)抗器(qi)、主變壓器(qi)、控制板的(de)溫度。

5、定期檢(jian)修主回路接觸器(qi)的觸頭(tou)。真空(kong)接觸器(qi)定期檢(jian)測絕緣(yuan)電(dian)阻,用5KV或2.5KV搖(yao)表檢(jian)查,當(dang)開關管(guan)絕緣(yuan)電(dian)阻小(xiao)于(yu)100兆歐時,應加強監(jian)視,小(xiao)于(yu)20兆歐時應立即更(geng)換新(xin)管(guan),以延(yan)長接觸器(qi)的使(shi)用壽命(ming),保障進相器(qi)及電(dian)機安全運行。

6、當(dang)進(jin)相器停用一段時(shi)間又重新(xin)啟用時(shi), 次進(jin)相前應觀察柜內控(kong)制單元上各(ge)指示(shi)燈(deng)是否正常(chang)。電機起動并正常(chang)運(yun)轉后,各(ge)指示(shi)燈(deng)顯示(shi)如下:

·主板(中間一塊):除L1,L2,L3周期性循環顯示(shi)外(注(zhu)意(yi):此指電機在運轉時(shi)的狀態,若(ruo)電機未轉,該三燈為隨機狀態),其它各燈均亮。

·驅(qu)動扳(ban)(兩(liang)邊的兩(liang)塊):其上面各(ge)指示(shi)燈均亮并(bing)有(you)輕(qing)微閃爍(shuo)。

7、當(dang)電機定(ding)子電流出(chu)現異常大幅(fu)擺動時,應立即退相,查出(chu)原因(yin)并檢修后投入使用。

8、定期打掃柜內衛(wei)生。

十一故障處(chu)理(li)



主電機不能起動(dong)

端子363、369無380V 電源

檢查起(qi)動柜控制電源

 

接觸器KM11不吸合

檢查KM11線包及其控制回路

 

接觸器KM11吸合,但其輔助觸點未閉合

檢(jian)修其輔助觸點

 

端子359、361串入合閘回路的線未接通

檢查(cha)該回路(lu)

不(bu)能投入進相

空氣開關QF1、QF2、QF3沒合上

合上空(kong)氣(qi)開關(guan)

 

按鈕STP、ST接觸不良

 

 

中間繼電器KA11觸點接觸不良

 

 

主電機起動柜內星點接觸器常開輔助觸點不能閉合(225、227未接通)

檢修該接觸器輔助(zhu)觸點(dian)及連線

 

KM13不能吸合

檢查KM13線包及其控制回路

 

固態繼電器FV損壞或者不導通

控制器主控制板L6燈滅

檢查主控板7腳對11、12、13腳有無+、-3伏左右電壓,否則更換電流傳感器

 

 

檢查固態繼電器FV

FV的3、4腳有直流(liu)15V電(dian)壓,而323、325不(bu)通(tong),須(xu)更換該繼電(dian)器

進(jin)相后主(zhu)電機停機

接入開關柜的KM11、KM13的輔助觸點359、361接觸不好

維修該觸點(dian)

 

進(jin)(jin)相器投入進(jin)(jin)相瞬間外部空氣(qi)開關跳閘

更換大規(gui)格(ge)的空氣開關

進相(xiang)后無效果

接入主(zhu)控(kong)板(ban)的電(dian)流傳感器信號線錯誤

電流傳感器從左到右TA1、TA2、TA3的信號線應分別對應與主控板的13、12、11腳

 

主控(kong)板的撥碼開關在自檢位(wei)

撥(bo)碼開關撥(bo)至工作(zuo)位

 

KM13吸合后KM11未(wei)釋(shi)放(時間繼電器KT11壞)

更換KT11時間繼電器

 

KM15沒有吸合

KM11的輔助觸(chu)點301、305接觸(chu)不良

維修該觸點

 

 

KM15線圈故障(zhang)

更換KM15線圈

 

KM15主(zhu)觸(chu)點接觸(chu)不(bu)良(liang)

更換KM15

 

主變壓(ya)器原邊(bian)開路

更換主(zhu)變壓器(qi)

進相后主(zhu)電機電流不減反(fan)增

同步(bu)電源相序錯(cuo)誤

調換進相器內小變壓器TC上輸出6V、6V0電壓的兩線位置

 

電機轉(zhuan)速下降(缺相),自動(dong)退相

KM13主觸(chu)點接觸(chu)不良

維修(xiu)該觸點(dian)

 

 

電機轉子線(xian)松動,進相(xiang)時的電流(liu)沖(chong)擊(ji)導致(zhi)缺相(xiang)

檢查電機轉子(zi)線

進相后主電機(ji)電流(liu)擺動大(da)

可控硅(gui)擊穿(chuan)

測(ce)量可控硅極間(jian)電阻(詳細方法見調(diao)試部(bu)分)

 

觸發板損壞

測量可控硅控制極與陰極之間應有0.2V以上的直流電壓信號,否則應檢查觸發板

 

主板的撥碼開關在自檢位

撥碼開關撥至工(gong)作位

 

電機(ji)轉子線松動

檢查(cha)電(dian)機轉子線

 

KM13采用節能型線圈時,線圈故障導致KM13進行瞬間來回釋放、吸合,導致主回路接觸不良

維修或更換KM13線圈





注意:進相器檢修不(bu)得(de)在進(jin)相(xiang)狀(zhuang)態下進(jin)行,發現問題應立即(ji)退相(xiang)。

十二控(kong)制(zhi)板檢修(xiu)



現象

原(yuan)因

對(dui)策(ce)

L1L2L3不循環閃爍,L6滅,其它各燈正常

轉子缺相(xiang)

檢查接觸器KM2主觸頭是否損壞,若損壞,則維修觸頭或更換接觸器

電流傳感器(qi)器(qi)損壞

檢查電流傳感器是否有±2V以上的輸出信號,否則更換傳感器

主控(kong)板元(yuan)器(qi)件損壞

依次更換IC210IC211

L1L2L3不周期性閃爍,其它各燈正常

主控板(ban)元器(qi)件損(sun)壞

依次更換IC210IC211IC205IC207

L6滅,其它各燈正常

主(zhu)控板(ban)元器件損壞

依次更換IC207IC209

L5滅,其它各燈正常

散熱(re)器(qi)溫度檢測回路故障

檢查溫度(du)開關及其連線

L4L7L8全部或部分滅

電源故障

1、檢查變壓器及控制板是否有±18V電源

2、更換相應的780578157915

F1-L1L6 F2-L1L6部分指示燈亮,主板各燈正常

觸發板元器件損(sun)壞

1、有一片ULN2004損壞,更換之

2、脈沖變壓器接觸不良,作相應處理

F1-L1L6 F2-L1L6指示燈全滅,主板各燈正常

觸發板元器件損壞

1、兩片ULN2004損壞,更換之

2、更換555芯片

觸(chu)發板無電源(yuan)

1、檢查主板7815是否有虛焊

2、檢查觸發板19腳與主板6腳連接是否正常





十三注意事項

1、進(jin)相器(qi)檢(jian)修應在退相狀態下進(jin)行,發(fa)現(xian)問題應立即退相。

2、嚴禁(jin)隨意帶(dai)電插拔(ba)控制(zhi)板(ban),檢修控制(zhi)板(ban)時(shi),一定要把空開QF3打下來。

3、更換(huan)可控(kong)硅時應注意陰(yin)、陽(yang)極的(de)方向,并(bing)壓(ya)(ya)緊散熱器(壓(ya)(ya)力不要過大),裝上后擰緊所有(you)螺絲,之后再(zai)檢測可控(kong)硅各極間的(de)電阻情況。若一(yi)只可控(kong)硅擊穿在柜(ju)體(ti)上直接檢測,同一(yi)相(xiang)的(de)四個(ge)可控(kong)硅均顯示(shi)擊穿,此(ci)時應把(ba)該組可控(kong)硅間的(de)聯接銅(tong)排拆(chai)掉再(zai)測 。

十四訂貨(huo)須知

1、提供電(dian)機型號、額定功率(lv)、定子電(dian)壓(ya)、定子電(dian)流(liu)、轉(zhuan)子電(dian)壓(ya)、轉(zhuan)子電(dian)流(liu)、額定功率(lv)因數。

2、提供電(dian)機拖動(dong)負載的(de)特征及負載率。

預知TP系列無環流靜止式進相器的更(geng)多信息,請撥(bo)打襄陽(yang)拓邦電(dian)氣官網電(dian)話(hua): 鄭(zheng)經理(li)17771133316或咨詢網站客服!!

在線留言