TP系列無環流靜止式進相器是襄陽拓邦電(dian)(dian)氣自(zi)選研制(zhi)開發的(de)(de)(de)(de)新一(yi)代(dai)高(gao)新技術(shu)產品,是一(yi)種專為大(da)中型繞線式(shi)(shi)異(yi)步電(dian)(dian)動(dong)機(ji)(ji)(ji)(ji)設計制(zhi)作(zuo)的(de)(de)(de)(de)就地無功功率(lv)補償裝置。它(ta)串接(jie)于(yu)電(dian)(dian)機(ji)(ji)(ji)(ji)轉子(zi)(zi)回路,改(gai)變(bian)轉子(zi)(zi)電(dian)(dian)流與轉子(zi)(zi)電(dian)(dian)壓的(de)(de)(de)(de)相(xiang)位關(guan)系,通過磁場(chang)進而(er)改(gai)變(bian)電(dian)(dian)機(ji)(ji)(ji)(ji)定子(zi)(zi)電(dian)(dian)流與電(dian)(dian)壓的(de)(de)(de)(de)相(xiang)位關(guan)系,達到提(ti)高(gao)電(dian)(dian)機(ji)(ji)(ji)(ji)自(zi)身(shen)功率(lv)因數、降低(di)電(dian)(dian)機(ji)(ji)(ji)(ji)定子(zi)(zi)電(dian)(dian)流和溫升(sheng)的(de)(de)(de)(de)目(mu)的(de)(de)(de)(de)。這種方式(shi)(shi)從根本(ben)(ben)上(shang)改(gai)善(shan)了電(dian)(dian)機(ji)(ji)(ji)(ji)的(de)(de)(de)(de)運行狀(zhuang)況(kuang),顯著降低(di)電(dian)(dian)機(ji)(ji)(ji)(ji)及電(dian)(dian)網的(de)(de)(de)(de)無功損(sun)耗,對節能降耗、降低(di)單位產品成本(ben)(ben),提(ti)高(gao)企業的(de)(de)(de)(de)經濟效益具有重(zhong)要的(de)(de)(de)(de)意義。
TP系列無(wu)環流(liu)靜止式(shi)進相器對無(wu)功(gong)(gong)(gong)功(gong)(gong)(gong)率(lv)的補(bu)(bu)償(chang)與電(dian)機(ji)(ji)定子側并聯電(dian)容器的補(bu)(bu)償(chang)有著本質的區別。電(dian)容補(bu)(bu)償(chang)只是在(zai)電(dian)機(ji)(ji)之外的電(dian)網上對無(wu)功(gong)(gong)(gong)進行補(bu)(bu)償(chang),減少電(dian)網的無(wu)功(gong)(gong)(gong)輸入(ru),電(dian)網的功(gong)(gong)(gong)率(lv)因數(shu)得(de)到(dao)提(ti)高,但是電(dian)機(ji)(ji)的無(wu)功(gong)(gong)(gong)消耗并沒(mei)有減少,無(wu)法(fa)改善電(dian)機(ji)(ji)本身(shen)的運(yun)行狀況(kuang);而TP系列靜止式進相器是串接在電機(ji)轉子(zi)回路中,不僅可顯著提高(gao)功(gong)率因數,使(shi)電機(ji)定子(zi)電流大幅度降(jiang)低(di),而(er)且電機(ji)溫升明顯降(jiang)低(di),電機(ji)的效率和過載能力顯著提高(gao)。
TP系列靜(jing)止式(shi)進(jin)(jin)(jin)相(xiang)(xiang)(xiang)器(qi)與(yu)自(zi)(zi)激(ji)(旋轉)式(shi)進(jin)(jin)(jin)相(xiang)(xiang)(xiang)機(ji)(ji)(ji)也(ye)不同。TP系列靜(jing)止式(shi)進(jin)(jin)(jin)相(xiang)(xiang)(xiang)器(qi)采用了 的(de)交-交變頻(pin)技(ji)(ji)術(shu)和微機(ji)(ji)(ji)、可控(kong)硅控(kong)制技(ji)(ji)術(shu),可自(zi)(zi)動跟(gen)蹤(zong)電機(ji)(ji)(ji)運行狀態的(de)變化(hua)并自(zi)(zi)動調(diao)整相(xiang)(xiang)(xiang)關參數(shu)以達到佳的(de)補償效果(guo),這是自(zi)(zi)激(ji)式(shi)進(jin)(jin)(jin)相(xiang)(xiang)(xiang)機(ji)(ji)(ji)無法(fa)做到的(de)。而(er)且,TP系列靜(jing)止式(shi)進(jin)(jin)(jin)相(xiang)(xiang)(xiang)器(qi)從根本上克服(fu)了自(zi)(zi)激(ji)式(shi)進(jin)(jin)(jin)相(xiang)(xiang)(xiang)機(ji)(ji)(ji)“整流(liu)子”結構特別怕塵埃、壽命(ming)短、維修頻(pin)繁的(de)缺點;具有(you)參數(shu)調(diao)節容易、主回路無轉動部件(jian)、不怕灰塵、可靠(kao)性高(gao)、使用壽命(ming)長(chang)、維護方便(bian),是理(li)想的(de)取代自(zi)(zi)激(ji)式(shi)進(jin)(jin)(jin)相(xiang)(xiang)(xiang)機(ji)(ji)(ji)的(de)新型(xing)高(gao)科技(ji)(ji)產品。
TP系列靜止(zhi)式(shi)進相(xiang)器可(ke)廣(guang)泛(fan)用于水泥(ni)、化(hua)工、礦山、冶金、鋼鐵、造紙、制藥等行(xing)業的(de)大中型高低壓繞線式(shi)異步(bu)電機。
二(er)型號命名
TP系列靜止式進相器型號命名方法如(ru)下:
型號(hao):TP-800,表示適用于額定(ding)轉子(zi)電流不超過800A的(de)電機的(de)靜止式進相器(qi)。
三工(gong)作原理(li)
當電(dian)(dian)(dian)(dian)(dian)(dian)機(ji)運行進(jin)(jin)相(xiang)(xiang)時,進(jin)(jin)相(xiang)(xiang)器(qi)通過轉(zhuan)(zhuan)子(zi)電(dian)(dian)(dian)(dian)(dian)(dian)流(liu)(liu)傳感(gan)器(qi)采集到(dao)的轉(zhuan)(zhuan)子(zi)電(dian)(dian)(dian)(dian)(dian)(dian)流(liu)(liu)信號及工頻(pin)(pin)電(dian)(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)提(ti)供(gong)的同步(bu)信號經微(wei)處(chu)理(li)器(qi)CPU進(jin)(jin)行數(shu)據和相(xiang)(xiang)位(wei)處(chu)理(li),控(kong)制可控(kong)硅的觸發信號,調整由12只晶(jing)閘(zha)管組成的交—交變頻(pin)(pin)裝置,將(jiang)降壓(ya)(ya)后的工頻(pin)(pin)電(dian)(dian)(dian)(dian)(dian)(dian)源變為和轉(zhuan)(zhuan)子(zi)電(dian)(dian)(dian)(dian)(dian)(dian)流(liu)(liu)同頻(pin)(pin)率,相(xiang)(xiang)位(wei)滯后90°的附加電(dian)(dian)(dian)(dian)(dian)(dian)勢加在電(dian)(dian)(dian)(dian)(dian)(dian)機(ji)轉(zhuan)(zhuan)子(zi)回路中(zhong)。轉(zhuan)(zhuan)子(zi)的電(dian)(dian)(dian)(dian)(dian)(dian)流(liu)(liu)和電(dian)(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)相(xiang)(xiang)位(wei)因此改變,通過磁場進(jin)(jin)而改變電(dian)(dian)(dian)(dian)(dian)(dian)機(ji)定子(zi)電(dian)(dian)(dian)(dian)(dian)(dian)流(liu)(liu)與(yu)定子(zi)電(dian)(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)的相(xiang)(xiang)位(wei)角(jiao),使電(dian)(dian)(dian)(dian)(dian)(dian)機(ji)的功(gong)率因數(shu)提(ti)高(gao),得到(dao)補償。
當電機在某(mou)一負載下運行時,其(qi)轉子電流(liu)為(wei)I2e、定子電流(liu)為(wei)I1e, 向量圖如下所示。
從(cong)電(dian)機學我們知道,激(ji)磁電(dian)流(liu)(liu)Im由關系(xi)(xi)式(shi)Im=I1e-I2e,從(cong)向量(liang)圖可得出(chu)(chu)Im。當進相(xiang)器的電(dian)勢疊加在轉(zhuan)子(zi)回路后,轉(zhuan)子(zi)電(dian)流(liu)(liu)的相(xiang)位變為(wei)圖中(zhong)的I2。由于負載不變,激(ji)磁電(dian)流(liu)(liu)Im不變。此時的定子(zi)電(dian)流(liu)(liu)I1由關系(xi)(xi)式(shi)I1=Im+I2從(cong)向量(liang)圖可得出(chu)(chu)I1,如圖所示。從(cong)圖中(zhong)可以看(kan)出(chu)(chu)I1的功率因數角和幅值都比I1e小(xiao),說明電(dian)機的功率因數有所提高,定子(zi)電(dian)流(liu)(liu)有所下(xia)降。
進相器(qi)就是這(zhe)樣改變(bian)轉子電(dian)流與轉子電(dian)壓的(de)相位關系,通過磁場進而改變(bian)電(dian)機定子電(dian)流與定子電(dian)壓的(de)相位關系,減小(xiao)功(gong)率(lv)因數角(jiao),終使電(dian)機本身(shen)的(de)功(gong)率(lv)因數得以(yi)提(ti)高,定子電(dian)流得以(yi)下降,達到對電(dian)機補償的(de)目的(de)。
當負載發生(sheng)改變時,微處(chu)理(li)器(qi)實時檢測電(dian)機參數的(de)變化,并根據(ju)負載的(de)變化,動態調整附加(jia)在轉子上的(de)電(dian)勢(shi)幅值,以使電(dian)機的(de)功率因(yin)數始(shi)終保持在期望值上。
四原理框圖
電容式補償的(de)矢量(liang)分析:
電容補(bu)(bu)償和進(jin)相器補(bu)(bu)償的原理圖分別如下:
圖中,將電(dian)機(ji)進行了等(deng)(deng)效(xiao)簡化,R1、X1為(wei)電(dian)機(ji)定子等(deng)(deng)效(xiao)電(dian)路(lu)(lu)的(de)(de)電(dian)阻和電(dian)感,R2、X2為(wei)電(dian)機(ji)轉子等(deng)(deng)效(xiao)電(dian)路(lu)(lu)的(de)(de)電(dian)阻和電(dian)感,C為(wei)就地(di)補償(chang)的(de)(de)電(dian)容,Uf為(wei)進相(xiang)器(qi)的(de)(de)等(deng)(deng)效(xiao)電(dian)路(lu)(lu),M為(wei)電(dian)機(ji)的(de)(de)接線點。
從圖(tu)可以看出(chu),靜止(zhi)式進相(xiang)器和(he)電容補(bu)償對電機的(de)(de)作(zuo)用點不同,電容是(shi)在電機的(de)(de)前(qian)端定子側(ce)進行補(bu)償,其補(bu)償范圍(wei)是(shi)在補(bu)償點的(de)(de)前(qian)端;靜止(zhi)式進相(xiang)器串聯在電機的(de)(de)后端,其補(bu)償范圍(wei)擴(kuo)大到了電機。
五性能(neng)特(te)點
1、可使電機的功率因數提(ti)高到0.95以上(shang),無功功率降低60%以上(shang)。
2、降低定(ding)子電流(liu)10%-20%。
3、降低線損、銅損20%-30%。
4、電機溫升降低(di)5%。
5、過(guo)載能力和效(xiao)率大大提(ti)高(gao),電機使用(yong)壽命延長(chang)。
6、具有(you)故障(zhang)自動保(bao)護功(gong)能,保(bao)障(zhang)設備(bei)長期安全運行(xing)。
7、操作簡單,安裝調試和(he)維(wei)修保養均不影響正(zheng)常生產,半年(nian)內可(ke)收(shou)回成(cheng)本。
六使用條件
1、安(an)裝(zhuang)地點環境溫度≤40℃
2、安裝(zhuang)地點相對濕度≤90%
3、 安裝地點無火(huo)災、爆炸危險品,無化學腐蝕及劇烈振動。
4、海拔高度≤1500M。
5、進(jin)相器柜體上(shang)方0.5米(mi)內應通風;如無地(di)溝,須將進(jin)相器柜體架空0.1米(mi)。
注(zhu):TP系(xi)列靜止式(shi)進相器應滿足(zu)上方(fang)要求的使(shi)用(yong)條(tiao)件,襄陽拓邦電氣還(huan)可提供適用于高原地(di)區(qu)(海拔超(chao)過1500米(mi))的靜止式進相器(但用(yong)戶須事先特別申請)。
七技術(shu)參(can)數
進 相 器 型 號 |
適 配 電 機 參 數 |
|
額定轉子電流(A) |
額定功率(KW) |
|
TP-400 |
≤400 |
95-800 |
TP-500 |
400-500 |
245-1000 |
TP-600 |
500-600 |
315-1250 |
TP-800 |
600-800 |
630-1600 |
TP-1000 |
800-1000 |
1000-2000 |
TP-1200 |
1000-1200 |
1600-2500 |
TP-1500 |
1200-1500 |
2000以上 |
八安(an)裝尺寸
1、外(wai)型尺寸圖
2、安裝基(ji)礎圖
3、規(gui)格尺(chi)寸表(biao)
型號 |
外形尺寸(MM) |
安裝尺寸(MM) |
||||
寬(W) |
深(D) |
高(H) |
寬(E) |
深(F) |
螺孔 |
|
TP400-600 |
1000 |
760 |
2000 |
780 |
620 |
14 |
TP800-1000 |
1100 |
800 |
2000 |
880 |
650 |
14 |
TP1200-1500 |
1200 |
900 |
2200 |
980 |
750 |
16 |
注:隨(sui)著產品(pin)不斷更新換代,外(wai)形及(ji)安裝尺(chi)寸(cun)會有所(suo)變化,請(qing)以具體的產品(pin)為準。
九安裝調試
(一)安(an)裝
1、將進相器搬到安(an)裝位置,注意進相器柜體底部應與地溝相通或架空,首先是(shi)打開柜子的前后(hou)門(men),從上(shang)到下,逐一地擰緊螺(luo)絲,防止在運輸過(guo)程中螺(luo)絲松(song)動造(zao)成進相器不能(neng)正常(chang)工作。
2、準備好連接(jie)【主電(dian)(dian)(dian)(dian)機(ji)轉(zhuan)子至(zhi)進相器(qi)接(jie)觸(chu)器(qi)KM13的(de)(de)三根電(dian)(dian)(dian)(dian)纜】、【進相器(qi)接(jie)觸(chu)器(qi)KM11至(zhi)主電(dian)(dian)(dian)(dian)機(ji)起動柜的(de)(de)三根電(dian)(dian)(dian)(dian)纜】,其線徑應能承載主電(dian)(dian)(dian)(dian)機(ji)轉(zhuan)子額定電(dian)(dian)(dian)(dian)流,比好長(chang)度并壓好接(jie)頭(tou)。
3、進相(xiang)器(qi)(qi)(qi)上(shang)的電(dian)(dian)(dian)流(liu)表、功率因數(shu)表是(shi)直(zhi)接從(cong)電(dian)(dian)(dian)機定(ding)(ding)子回路上(shang)的電(dian)(dian)(dian)流(liu)互(hu)(hu)感(gan)(gan)器(qi)(qi)(qi)、電(dian)(dian)(dian)壓(ya)(ya)互(hu)(hu)感(gan)(gan)器(qi)(qi)(qi)取信號,要(yao)求所用電(dian)(dian)(dian)流(liu)互(hu)(hu)感(gan)(gan)器(qi)(qi)(qi)副邊的額定(ding)(ding)電(dian)(dian)(dian)流(liu)為5A、電(dian)(dian)(dian)壓(ya)(ya)互(hu)(hu)感(gan)(gan)器(qi)(qi)(qi)副邊的額定(ding)(ding)電(dian)(dian)(dian)壓(ya)(ya)為100V,若用戶現用的不滿足該要(yao)求,則須另行(xing)準備符合(he)上(shang)述要(yao)求的互(hu)(hu)感(gan)(gan)器(qi)(qi)(qi)。(注(zhu):電(dian)(dian)(dian)壓(ya)(ya)互(hu)(hu)感(gan)(gan)器(qi)(qi)(qi)僅適用于高壓(ya)(ya)電(dian)(dian)(dian)機,對低壓(ya)(ya)電(dian)(dian)(dian)機,進相(xiang)器(qi)(qi)(qi)電(dian)(dian)(dian)壓(ya)(ya)信號直(zhi)接從(cong)定(ding)(ding)子回路取)
4、新電機須帶上90%以(yi)上負載并正(zheng)常運轉(zhuan)后(hou)才可(ke)調試(shi)進相器,用戶在(zai)通知我方調試(shi)前,應(ying)調試(shi)好電機、減速機、磨機等其(qi)它設備,使其(qi)帶上負載正(zheng)常運轉(zhuan),以(yi)免延(yan)誤進相器調試(shi)時間。
5、各聯鎖線意(yi)義如下:
(225、227)取自電機(ji)起動(dong)柜星(xing)點短接接觸器(qi)的輔助常開點,只有在電機(ji)起動(dong)完畢后,進相器(qi)才可(ke)以進相。
(355、357)當開關柜(ju)主開關是(shi)接觸器時與分閘(zha)按鈕(niu)并聯(lian);是(shi)斷(duan)路器時與分閘(zha)按鈕(niu)串(chuan)聯(lian), 進相狀態下主電機不能停機,只有先退(tui)相才(cai)能停主機。
(359、361)串入開關柜(ju)合閘回路。當(dang)KM11吸合時,可以起動電機。
(363、369)從起動(dong)柜(ju)控(kong)(kong)制電(dian)源(yuan)引單(dan)相380V,使(shi)KM11與起動(dong)柜(ju)控(kong)(kong)制回路同時得電(dian)。
(30、32)串入(ru)主(zhu)電(dian)機電(dian)流計量(liang)回路;(40、42)并(bing)入(ru)主(zhu)電(dian)機電(dian)壓(ya)計量(liang)回路。(取A相(xiang)電(dian)流則取B,C相(xiang)電(dian)壓(ya),如(ru)此類推,電(dian)流和電(dian)壓(ya)不得取同相(xiang))。
(A、B、C、N)接三相四線(xian)(xian)電(dian)源,導(dao)線(xian)(xian)橫(heng)截面(mian)積:TP600以(yi)下用4mm2;TP1000以(yi)下用6mm2;TP1500以(yi)下用10mm2。
6、控(kong)制器(qi)所有指(zhi)示燈的(de)含義說明如下:
(1)主板(中間一塊)的指示燈(deng)(從上往下數)
●L1、L2、L3:電(dian)機轉子三(san)相電(dian)流(liu)信號指示(電(dian)機運轉時(shi)為循環顯示狀態;自檢(jian)試驗時(shi)為隨機狀態:或亮、或滅)
●L4:+5V電源指示(保持亮(liang)的(de)狀(zhuang)態(tai))
●L5:熱故障(zhang)指示(有(you)熱故障(zhang)時L5滅)
●L6:缺相及自動故障保護指示(shi)(有(you)缺相故障及其它(ta)故障時L6燈(deng)滅)
●L7:+15V電(dian)源指示(保持亮的狀態)
●L8:-15V電源(yuan)指(zhi)示(保持亮的狀(zhuang)態)
(2)驅動(dong)板(兩(liang)邊兩(liang)塊(kuai))
●分別代表12個可控制(zhi)硅的(de)(de)觸發信號(指示(shi)燈均亮(liang),并有規律的(de)(de)閃爍)
(二(er))試(shi)驗
1、檢查主電纜、聯鎖(suo)線(xian)、儀表(biao)線(xian)連接是否正確。
2、檢查各器件螺絲是否緊(jin)固。
3、用萬(wan)用表測量可控硅極間電阻:
●觸(chu)發(fa)極G與(yu)陰極K間電阻為幾十歐(ou)姆(mu);
●觸發極G與陽極A間電(dian)阻大于幾十千歐;
●陰極(ji)K與陽極(ji)A間電阻大于幾(ji)十千歐;
●陰極K與陽(yang)極A用萬用表200K檔測量,阻(zu)值(zhi)應(ying)從小變化(hua)到(dao)無限大(da)。
4、合(he)上(shang)起動柜電(dian)(dian)源(yuan),進相器(qi)背(bei)面的接觸器(qi)KM11應(ying)吸合(he),短接225、227;合(he)上(shang)進相器(qi)電(dian)(dian)源(yuan),電(dian)(dian)源(yuan)指示燈亮;控制器(qi)應(ying)有(you)電(dian)(dian),控制器(qi)上(shang)指示燈亮。
5、控制器上撥碼開關打在ON(上方)位置,中間(jian)主板(ban)L1、L2、L3循環亮或(huo)滅,L4~L8全亮;兩(liang)(liang)邊兩(liang)(liang)塊驅動板(ban)指示燈閃爍(shuo)。
6、按綠色(se)(se)進(jin)相按鈕,進(jin)相器(qi)(qi)前面(mian)的接觸器(qi)(qi)KM13吸合,延時后,背面(mian)的接觸器(qi)(qi)KM11斷開,綠色(se)(se)進(jin)相指(zhi)示燈亮,風(feng)機(ji)運轉,風(feng)應向上吹,主變壓器(qi)(qi)副邊電流不超過(guo)30A,并且沒有大幅度變化(hua)。
7、按紅色(se)(se)退(tui)相(xiang)(xiang)按鈕(niu),進(jin)相(xiang)(xiang)器(qi)后面的接觸(chu)器(qi)KM11吸合,延時后,前面的接觸(chu)器(qi)KM13斷(duan)開,綠色(se)(se)進(jin)相(xiang)(xiang)指示燈(deng)(deng)滅,紅色(se)(se)電源指示燈(deng)(deng)亮,進(jin)相(xiang)(xiang)器(qi)即退(tui)出進(jin)相(xiang)(xiang)狀態。
8、通電試(shi)驗結束,請務必斷開225、227。
(三(san))調試(shi)
1、運行前:控制器主板上(shang)撥碼開關應打在(zai)OFF(下方)位置(zhi)。
2、起(qi)動主(zhu)電機:打(da)開進相器前柜門,合上空氣開關,進相器電源接通,面板上的紅(hong)色電源指示燈亮(liang),關閉(bi)柜門,等待主(zhu)機起(qi)動。
3、進(jin)相(xiang):(1)電機(ji)正(zheng)常(chang)運(yun)轉后,按(an)(an)綠色(se)進(jin)相(xiang)按(an)(an)鈕,進(jin)相(xiang)器(qi)前(qian)面的接(jie)觸器(qi)KM13吸(xi)合,延時(shi)后,背(bei)面的接(jie)觸器(qi)KM11斷開,綠色(se)進(jin)相(xiang)指(zhi)示燈亮,風(feng)機(ji)運(yun)轉,定子電流應下(xia)降(jiang),功率因數應上(shang)升。如果定子電流不下(xia)降(jiang)反而上(shang)升,調整同步變(bian)壓器(qi)上(shang)6V、6V0兩線的位置,再進(jin)相(xiang)。
(2)測量主變(bian)壓器原、副邊電流,應無大(da)幅度(du)擺動。
(3)電機定(ding)子(zi)電流(liu)應平穩,無大幅(fu)度擺動。
(4)六個電抗器上(shang)端銅(tong)排的電流(liu)擺動幅度應一致。
4、退相:按(an)紅色退相按(an)鈕(niu),進(jin)相器(qi)(qi)后面(mian)的接觸器(qi)(qi)KM11吸合(he),延(yan)時后,前面(mian)的接觸器(qi)(qi)KM13斷開(kai),綠色進(jin)相指示燈滅,紅色電(dian)源指示燈亮(liang),進(jin)相器(qi)(qi)即退出進(jin)相狀態。
5、停(ting)車:進相器退相后,按(an)下主機停(ting)車按(an)鈕,電機即停(ting)車。
(四(si))測量和觀察
1、測量可控硅、銅(tong)排、交(jiao)流接觸(chu)器(qi)、電抗(kang)器(qi)、主變壓器(qi)、控制板溫度(du)。
2、測量(liang)可控(kong)硅(gui)觸發電壓;主變(bian)壓器一次、二次電流(liu);電抗器輸(shu)入電流(liu)。
3、觀(guan)察風機運行情況。
4、觀察整(zheng)體運(yun)行情(qing)況,有(you)無(wu)異常響聲或銅排有(you)無(wu)大的抖動現象等。
十使用維(wei)護
為確(que)保TP系列靜止式進相器長(chang)期安全、可(ke)靠地運行,請操作(zuo)人(ren)員特別注意(yi)以下事項(xiang):
1、嚴禁在進相(xiang)器(qi)運行期間,切斷進相(xiang)器(qi)外部(bu)電源。
2、定(ding)期(qi)檢(jian)查冷卻風機運轉狀況,冷卻風機停轉使(shi)可(ke)控硅(gui)散熱能(neng)力下降(jiang),可(ke)能(neng)燒壞可(ke)控硅(gui)。
3、定期檢(jian)測主(zhu)變壓器原、副邊(bian)運行(xing)電流。
4、定期檢測可控硅、聯接(jie)銅排、交流接(jie)觸器(qi)、電(dian)抗器(qi)、主變壓器(qi)、控制(zhi)板的溫度。
5、定期檢修(xiu)主回路接(jie)觸(chu)(chu)器(qi)的觸(chu)(chu)頭。真(zhen)空接(jie)觸(chu)(chu)器(qi)定期檢測絕(jue)緣電阻,用(yong)5KV或2.5KV搖表檢查,當(dang)開關管絕(jue)緣電阻小于100兆歐時,應加強監視,小于20兆歐時應立即更換(huan)新管,以延長接(jie)觸(chu)(chu)器(qi)的使用(yong)壽命(ming),保障(zhang)進相器(qi)及電機(ji)安全運行。
6、當進(jin)相器(qi)停用(yong)一段(duan)時間又(you)重新(xin)啟用(yong)時, 次進(jin)相前(qian)應(ying)觀察柜內控制單元上各指示燈(deng)是否(fou)正(zheng)常。電機起動并正(zheng)常運轉后,各指示燈(deng)顯示如下:
·主板(中間一(yi)塊):除L1,L2,L3周期性循(xun)環顯示外(注(zhu)意:此指電機在運轉時(shi)的狀態,若電機未(wei)轉,該三燈為隨機狀態),其它各(ge)燈均亮。
·驅(qu)動扳(兩(liang)邊(bian)的兩(liang)塊(kuai)):其上面各指示燈均亮(liang)并(bing)有輕微閃爍。
7、當(dang)電(dian)機定(ding)子電(dian)流出現異常(chang)大幅擺動(dong)時(shi),應立即(ji)退相,查出原因并檢修后投入使用。
8、定期打掃柜內衛生。
十(shi)一故障處理
主電機不(bu)能起動 |
端子363、369無380V 電源 |
檢查起動柜控制電(dian)源(yuan) |
||
|
接觸器KM11不吸合 |
檢查KM11線包及其控制回路 |
||
|
接觸器KM11吸合,但其輔助觸點未閉合 |
檢(jian)修其輔助(zhu)觸(chu)點 |
||
|
端子359、361串入合閘回路的線未接通 |
檢查該回路 |
||
不能投入進相 |
空氣開關QF1、QF2、QF3沒合上 |
合(he)上空氣(qi)開關 |
||
|
按鈕STP、ST接觸不良 |
|
||
|
中間繼電器KA11觸點接觸不良 |
|
||
|
主電機起動柜內星點接觸器常開輔助觸點不能閉合(225、227未接通) |
檢修該接(jie)觸(chu)器輔助觸(chu)點及(ji)連線 |
||
|
KM13不能吸合 |
檢查KM13線包及其控制回路 |
||
|
固態繼電器FV損壞或者不導通 |
控制器主控制板L6燈滅 |
檢查主控板7腳對11、12、13腳有無+、-3伏左右電壓,否則更換電流傳感器 |
|
|
|
檢查固態繼電器FV |
FV的(de)3、4腳有直(zhi)流15V電壓,而323、325不(bu)通,須更換該繼電器 |
|
進相(xiang)后(hou)主(zhu)電機停機 |
接入開關柜的KM11、KM13的輔助觸點359、361接觸不好 |
維(wei)修該觸點 |
||
|
進相(xiang)器投入進相(xiang)瞬間外部(bu)空氣開關跳閘(zha) |
更換大規格的(de)空氣開關 |
||
進(jin)相(xiang)后無(wu)效果(guo) |
接入(ru)主控(kong)板的(de)電流傳(chuan)感器(qi)信(xin)號(hao)線錯(cuo)誤 |
電流傳感器從左到右TA1、TA2、TA3的信號線應分別對應與主控板的13、12、11腳 |
||
|
主控板(ban)的撥碼開(kai)關在自檢位 |
撥碼開關(guan)撥至工作位 |
||
|
KM13吸(xi)合后KM11未釋放(時間(jian)繼(ji)電器(qi)KT11壞) |
更換KT11時間繼電器 |
||
|
KM15沒有吸合 |
KM11的輔助觸點301、305接觸不良 |
維修該觸點 |
|
|
|
KM15線圈故(gu)障 |
更換KM15線圈 |
|
|
KM15主觸點接觸不良 |
更換KM15 |
||
|
主變壓器原(yuan)邊開路 |
更換主(zhu)變壓(ya)器 |
||
進相后主(zhu)電機電流不減反增 |
同步電(dian)源相序錯誤 |
調換進相器內小變壓器TC上輸出6V、6V0電壓的兩線位置 |
||
|
電機轉速(su)下降(缺相),自動退相 |
KM13主觸點接觸不良 |
維修該觸點 |
|
|
|
電(dian)機轉子線松動,進(jin)相時的電(dian)流沖(chong)擊導致缺相 |
檢查(cha)電機轉子(zi)線(xian) |
|
進相后(hou)主電(dian)機電(dian)流擺動大 |
可控硅擊穿(chuan) |
測量可控硅極間電阻(詳細方法見調(diao)試部分) |
||
|
觸發板損壞 |
測量可控硅控制極與陰極之間應有0.2V以上的直流電壓信號,否則應檢查觸發板 |
||
|
主板的(de)撥碼(ma)開關(guan)在自檢位 |
撥碼開關撥至工作(zuo)位 |
||
|
電機轉子線松(song)動 |
檢查電(dian)機轉子(zi)線 |
||
|
當KM13采用節能型線圈時,線圈故障導致KM13進行瞬間來回釋放、吸合,導致主回路接觸不良 |
維修或更換KM13線圈 |
注意:進相器檢修不得在(zai)進相(xiang)(xiang)狀態下進行,發現問題(ti)應立即退(tui)相(xiang)(xiang)。
十二(er)控(kong)制板檢(jian)修
現象 |
原因 |
對策 |
L1、L2、L3不循環閃爍,L6滅,其它各燈正常 |
轉子缺相(xiang) |
檢查接觸器KM2主觸頭是否損壞,若損壞,則維修觸頭或更換接觸器 |
電流傳感(gan)器器損(sun)壞 |
檢查電流傳感器是否有±2V以上的輸出信號,否則更換傳感器 |
|
主控板(ban)元器件損壞 |
依次更換IC210、IC211 |
|
L1、L2、L3不周期性閃爍,其它各燈正常 |
主(zhu)控板元器件(jian)損壞 |
依次更換IC210、IC211、IC205、IC207 |
L6滅,其它各燈正常 |
主(zhu)控板元(yuan)器(qi)件(jian)損壞 |
依次更換IC207、IC209 |
L5滅,其它各燈正常 |
散熱器(qi)溫度檢(jian)測回(hui)路故障(zhang) |
檢查(cha)溫度(du)開關(guan)及其連線 |
L4、L7、L8全部或部分滅 |
電源故障 |
1、檢查變壓器及控制板是否有±18V電源 2、更換相應的7805、7815、7915 |
F1-L1~L6 或F2-L1~L6部分指示燈亮,主板各燈正常 |
觸發板元器(qi)件損(sun)壞 |
1、有一片ULN2004損壞,更換之 2、脈沖變壓器接觸不良,作相應處理 |
F1-L1~L6 或F2-L1~L6指示燈全滅,主板各燈正常 |
觸發板元器(qi)件損壞 |
1、兩片ULN2004損壞,更換之 2、更換555芯片 |
觸發板無電(dian)源 |
1、檢查主板7815是否有虛焊 2、檢查觸發板19腳與主板6腳連接是否正常 |
十三注意事項(xiang)
1、進(jin)(jin)相(xiang)器(qi)檢修(xiu)應在退(tui)相(xiang)狀態下(xia)進(jin)(jin)行,發現問題(ti)應立即退(tui)相(xiang)。
2、嚴禁隨意帶電(dian)插拔(ba)控制(zhi)板,檢修控制(zhi)板時,一定(ding)要把空開QF3打下來(lai)。
3、更換可(ke)控(kong)硅(gui)(gui)時應(ying)注意(yi)陰、陽極(ji)的方(fang)向(xiang),并壓緊(jin)散熱器(壓力不要過大),裝(zhuang)上后擰緊(jin)所有螺絲,之后再檢測(ce)可(ke)控(kong)硅(gui)(gui)各極(ji)間(jian)的電阻情況(kuang)。若一(yi)只可(ke)控(kong)硅(gui)(gui)擊穿(chuan)在柜體上直接檢測(ce),同一(yi)相的四個可(ke)控(kong)硅(gui)(gui)均(jun)顯示擊穿(chuan),此時應(ying)把該(gai)組(zu)可(ke)控(kong)硅(gui)(gui)間(jian)的聯接銅(tong)排拆掉再測(ce) 。
十四(si)訂貨須知
1、提供(gong)電機(ji)型號、額定(ding)功率、定(ding)子電壓(ya)、定(ding)子電流、轉子電壓(ya)、轉子電流、額定(ding)功率因數。
2、提供電機(ji)拖動負載的(de)特(te)征及負載率。
預知TP系列無環流靜止式進相器的(de)更多信(xin)息(xi),請撥打襄陽拓邦電氣官(guan)網電話: 鄭經理(li)17771133316或咨詢網站(zhan)客服!!