欧美最猛性XXXXX69交_亚洲精品无码永久电影在线_欧美黑人粗大xxxxbbbb_中文字幕日韩精品有码视频

泉州產品中心
泉州產品中心

泉州產品中心

product

泉州TP系列靜止式進相器

一(yi)(yi)概述TP系列無環流靜止式(shi)進相器是襄(xiang)陽拓邦電(dian)氣自選研制開發的新一(yi)(yi)代高新技術產品,是一(yi)(yi)種專為大中型繞線式(shi)異……

相關內容
在線留言
詳情內容
content details

TP系列無環流靜止式進相器是襄陽(yang)拓(tuo)邦(bang)電(dian)(dian)(dian)(dian)氣自選研制開發的(de)(de)(de)新(xin)一代高(gao)新(xin)技術產(chan)品,是一種(zhong)專為大中(zhong)型繞線(xian)式(shi)異步電(dian)(dian)(dian)(dian)動機設計制作的(de)(de)(de)就地無(wu)功(gong)功(gong)率(lv)補償裝置。它串(chuan)接于電(dian)(dian)(dian)(dian)機轉子(zi)回路,改變(bian)轉子(zi)電(dian)(dian)(dian)(dian)流與(yu)轉子(zi)電(dian)(dian)(dian)(dian)壓(ya)的(de)(de)(de)相(xiang)位(wei)關系,通過磁場進而改變(bian)電(dian)(dian)(dian)(dian)機定子(zi)電(dian)(dian)(dian)(dian)流與(yu)電(dian)(dian)(dian)(dian)壓(ya)的(de)(de)(de)相(xiang)位(wei)關系,達到提高(gao)電(dian)(dian)(dian)(dian)機自身功(gong)率(lv)因數、降(jiang)低電(dian)(dian)(dian)(dian)機定子(zi)電(dian)(dian)(dian)(dian)流和(he)溫升的(de)(de)(de)目的(de)(de)(de)。這種(zhong)方式(shi)從根(gen)本上改善了電(dian)(dian)(dian)(dian)機的(de)(de)(de)運行狀況,顯著降(jiang)低電(dian)(dian)(dian)(dian)機及電(dian)(dian)(dian)(dian)網的(de)(de)(de)無(wu)功(gong)損耗(hao),對節能降(jiang)耗(hao)、降(jiang)低單位(wei)產(chan)品成本,提高(gao)企業的(de)(de)(de)經濟(ji)效益具有(you)重要(yao)的(de)(de)(de)意義。


TP系列無(wu)(wu)環(huan)流靜止式進相器對無(wu)(wu)功功率的補(bu)償(chang)與電(dian)(dian)(dian)機(ji)(ji)定(ding)子側并(bing)聯(lian)電(dian)(dian)(dian)容(rong)器的補(bu)償(chang)有(you)著本質的區別。電(dian)(dian)(dian)容(rong)補(bu)償(chang)只是在電(dian)(dian)(dian)機(ji)(ji)之外的電(dian)(dian)(dian)網(wang)上對無(wu)(wu)功進行(xing)補(bu)償(chang),減少電(dian)(dian)(dian)網(wang)的無(wu)(wu)功輸(shu)入,電(dian)(dian)(dian)網(wang)的功率因(yin)數得(de)到提高(gao),但是電(dian)(dian)(dian)機(ji)(ji)的無(wu)(wu)功消耗(hao)并(bing)沒有(you)減少,無(wu)(wu)法改善電(dian)(dian)(dian)機(ji)(ji)本身(shen)的運行(xing)狀況;而(er)TP系列靜止式進相器是串接在電(dian)(dian)機轉(zhuan)子回(hui)路(lu)中,不僅(jin)可顯(xian)著(zhu)提高功率因數,使電(dian)(dian)機定(ding)子電(dian)(dian)流大幅度降(jiang)低,而且電(dian)(dian)機溫升明顯(xian)降(jiang)低,電(dian)(dian)機的效率和(he)過(guo)載能(neng)力(li)顯(xian)著(zhu)提高。

TP系列(lie)靜(jing)止(zhi)式進(jin)相(xiang)(xiang)(xiang)器與自(zi)激(ji)(ji)(旋(xuan)轉(zhuan))式進(jin)相(xiang)(xiang)(xiang)機(ji)(ji)(ji)也不同(tong)。TP系列(lie)靜(jing)止(zhi)式進(jin)相(xiang)(xiang)(xiang)器采用(yong)了(le) 的(de)交-交變頻(pin)技(ji)術(shu)和(he)微機(ji)(ji)(ji)、可(ke)(ke)控(kong)硅控(kong)制技(ji)術(shu),可(ke)(ke)自(zi)動跟蹤電機(ji)(ji)(ji)運(yun)行(xing)狀態(tai)的(de)變化(hua)并(bing)自(zi)動調整(zheng)(zheng)相(xiang)(xiang)(xiang)關參數以達到(dao)佳的(de)補償效果,這是自(zi)激(ji)(ji)式進(jin)相(xiang)(xiang)(xiang)機(ji)(ji)(ji)無法(fa)做到(dao)的(de)。而(er)且,TP系列(lie)靜(jing)止(zhi)式進(jin)相(xiang)(xiang)(xiang)器從根(gen)本(ben)上(shang)克(ke)服了(le)自(zi)激(ji)(ji)式進(jin)相(xiang)(xiang)(xiang)機(ji)(ji)(ji)“整(zheng)(zheng)流(liu)子”結構特(te)別怕塵(chen)埃、壽命(ming)短、維修頻(pin)繁的(de)缺點;具有參數調節(jie)容易、主回路無轉(zhuan)動部件(jian)、不怕灰塵(chen)、可(ke)(ke)靠性高、使用(yong)壽命(ming)長、維護方便,是理想的(de)取代自(zi)激(ji)(ji)式進(jin)相(xiang)(xiang)(xiang)機(ji)(ji)(ji)的(de)新型高科技(ji)產(chan)品。

TP系列(lie)靜止(zhi)式(shi)進相器可廣泛(fan)用于(yu)水泥、化工(gong)、礦山、冶金、鋼(gang)鐵(tie)、造(zao)紙、制藥等(deng)行(xing)業(ye)的(de)大中型(xing)高(gao)低壓繞線(xian)式(shi)異步電機。


二型號命(ming)名(ming)

TP系列靜止式進相器型號命名方法如下:





型號:TP-800,表示(shi)適(shi)用于額定轉子電流(liu)不(bu)超過800A的(de)電機的(de)靜止式進(jin)相器(qi)。


三(san)工作原(yuan)理

當電(dian)(dian)(dian)機(ji)(ji)運行進相(xiang)時,進相(xiang)器通過轉(zhuan)(zhuan)子電(dian)(dian)(dian)流(liu)傳感器采集到的(de)(de)(de)轉(zhuan)(zhuan)子電(dian)(dian)(dian)流(liu)信(xin)號(hao)及工頻(pin)電(dian)(dian)(dian)壓(ya)提(ti)供的(de)(de)(de)同步(bu)信(xin)號(hao)經微處理(li)器CPU進行數據和相(xiang)位處理(li),控制可控硅的(de)(de)(de)觸發信(xin)號(hao),調整由12只晶閘管(guan)組成的(de)(de)(de)交—交變頻(pin)裝置,將降壓(ya)后(hou)的(de)(de)(de)工頻(pin)電(dian)(dian)(dian)源變為和轉(zhuan)(zhuan)子電(dian)(dian)(dian)流(liu)同頻(pin)率,相(xiang)位滯后(hou)90°的(de)(de)(de)附(fu)加電(dian)(dian)(dian)勢加在電(dian)(dian)(dian)機(ji)(ji)轉(zhuan)(zhuan)子回路中。轉(zhuan)(zhuan)子的(de)(de)(de)電(dian)(dian)(dian)流(liu)和電(dian)(dian)(dian)壓(ya)相(xiang)位因此改變,通過磁場進而改變電(dian)(dian)(dian)機(ji)(ji)定子電(dian)(dian)(dian)流(liu)與定子電(dian)(dian)(dian)壓(ya)的(de)(de)(de)相(xiang)位角,使電(dian)(dian)(dian)機(ji)(ji)的(de)(de)(de)功(gong)率因數提(ti)高,得(de)到補償。

當電機(ji)在某一負載(zai)下運行時,其轉(zhuan)子電流(liu)為I2e、定(ding)子電流(liu)為I1e, 向(xiang)量圖(tu)如下所示。







從(cong)(cong)電機學我們知道(dao),激(ji)磁電流(liu)(liu)(liu)Im由(you)關(guan)系式(shi)(shi)Im=I1e-I2e,從(cong)(cong)向(xiang)量(liang)圖(tu)(tu)可(ke)得出Im。當進相器(qi)的(de)電勢疊(die)加在(zai)轉子(zi)回路(lu)后,轉子(zi)電流(liu)(liu)(liu)的(de)相位(wei)變為(wei)圖(tu)(tu)中的(de)I2。由(you)于負載(zai)不變,激(ji)磁電流(liu)(liu)(liu)Im不變。此(ci)時的(de)定子(zi)電流(liu)(liu)(liu)I1由(you)關(guan)系式(shi)(shi)I1=Im+I2從(cong)(cong)向(xiang)量(liang)圖(tu)(tu)可(ke)得出I1,如圖(tu)(tu)所示。從(cong)(cong)圖(tu)(tu)中可(ke)以看出I1的(de)功率因數角和幅值都比I1e小,說(shuo)明電機的(de)功率因數有所提高,定子(zi)電流(liu)(liu)(liu)有所下降(jiang)。

進相(xiang)器就是這樣改變轉(zhuan)子電流(liu)與轉(zhuan)子電壓(ya)的(de)(de)(de)相(xiang)位(wei)關系,通過磁場進而(er)改變電機(ji)(ji)定子電流(liu)與定子電壓(ya)的(de)(de)(de)相(xiang)位(wei)關系,減小功率因數角,終(zhong)使電機(ji)(ji)本身的(de)(de)(de)功率因數得以提高,定子電流(liu)得以下降,達(da)到對電機(ji)(ji)補償的(de)(de)(de)目(mu)的(de)(de)(de)。

當負載發生(sheng)改變(bian)時,微處理器實時檢測電(dian)機參數(shu)的(de)變(bian)化,并根(gen)據負載的(de)變(bian)化,動態調(diao)整(zheng)附(fu)加在轉子上的(de)電(dian)勢(shi)幅值,以(yi)使電(dian)機的(de)功率因數(shu)始終(zhong)保持在期望值上。

四原(yuan)理框圖






電容式補償的矢量分(fen)析:








電容(rong)補(bu)償和進相器補(bu)償的原理圖(tu)分別(bie)如下(xia):






圖中,將電(dian)(dian)機(ji)(ji)(ji)進(jin)(jin)行了等(deng)效簡(jian)化,R1、X1為電(dian)(dian)機(ji)(ji)(ji)定子等(deng)效電(dian)(dian)路(lu)的(de)(de)電(dian)(dian)阻和(he)電(dian)(dian)感,R2、X2為電(dian)(dian)機(ji)(ji)(ji)轉子等(deng)效電(dian)(dian)路(lu)的(de)(de)電(dian)(dian)阻和(he)電(dian)(dian)感,C為就地補償的(de)(de)電(dian)(dian)容,Uf為進(jin)(jin)相(xiang)器的(de)(de)等(deng)效電(dian)(dian)路(lu),M為電(dian)(dian)機(ji)(ji)(ji)的(de)(de)接線點。

從圖(tu)可以看出,靜止(zhi)(zhi)式(shi)進(jin)相器和電(dian)(dian)容補(bu)償(chang)對電(dian)(dian)機(ji)的(de)作用點不同(tong),電(dian)(dian)容是在(zai)電(dian)(dian)機(ji)的(de)前端定子側進(jin)行補(bu)償(chang),其補(bu)償(chang)范(fan)圍是在(zai)補(bu)償(chang)點的(de)前端;靜止(zhi)(zhi)式(shi)進(jin)相器串聯在(zai)電(dian)(dian)機(ji)的(de)后端,其補(bu)償(chang)范(fan)圍擴(kuo)大到了電(dian)(dian)機(ji)。

五性能特(te)點(dian)

1、可使電機的功(gong)率(lv)因數(shu)提(ti)高到0.95以(yi)上,無功(gong)功(gong)率(lv)降低60%以(yi)上。

2、降低定子電流10%-20%。

3、降低(di)線損(sun)、銅損(sun)20%-30%。

4、電機溫(wen)升降低5%。

5、過載能力和效率大大提高,電機(ji)使用壽(shou)命延長。

6、具有故障自動保(bao)護功能,保(bao)障設備長期安全運行(xing)。

7、操作(zuo)簡單,安裝調(diao)試和維(wei)修保養均不影響正常生產,半年內可收回成本。

六使用條(tiao)件

1、安裝地點環境溫度≤40℃

2、安裝地(di)點相對濕度≤90%

3、 安裝地(di)點無火(huo)災、爆炸危險(xian)品,無化學(xue)腐蝕及劇烈振動。

4、海拔高度≤1500M。

5、進相(xiang)器(qi)柜(ju)體(ti)上方0.5米內應通風;如無地溝(gou),須將進相(xiang)器(qi)柜(ju)體(ti)架空0.1米。

注:TP系列(lie)靜止式進相器應滿足上方(fang)要求的使用條件,襄陽拓邦電氣還可提供(gong)適用于高原地區(海拔(ba)超過1500米)的靜止式進相器(但用戶須事先特別(bie)申請(qing))。

七技術(shu)參數


相 器 型 號

配 電 機 參 數

額定轉子電流(A

額定功率(KW

TP-400

400

95-800

TP-500

400-500

245-1000

TP-600

500-600

315-1250

TP-800

600-800

630-1600

TP-1000

800-1000

1000-2000

TP-1200

1000-1200

1600-2500

TP-1500

1200-1500

2000以上




八安(an)裝(zhuang)尺寸

1、外型(xing)尺寸圖(tu)






2、安裝基(ji)礎圖(tu)







3、規(gui)格(ge)尺寸(cun)表



型號

外形尺寸(MM)

安裝尺寸(MM)

(W)

(D)

(H)

(E)

(F)

螺孔

TP400-600

1000

760

2000

780

620

14

TP800-1000

1100

800

2000

880

650

14

TP1200-1500

1200

900

2200

980

750

16



注:隨著產品不斷更新換代,外形及安裝尺(chi)寸會有所(suo)變化,請以具體的產品為準(zhun)。

九安裝調試

(一(yi))安(an)裝

1、將進(jin)(jin)相(xiang)(xiang)器(qi)(qi)搬到安裝位置(zhi),注意進(jin)(jin)相(xiang)(xiang)器(qi)(qi)柜體底部應(ying)與地溝(gou)相(xiang)(xiang)通或架(jia)空,首先(xian)是打開柜子的前后門,從上到下(xia),逐(zhu)一(yi)地擰(ning)緊螺(luo)絲,防止在(zai)運輸過(guo)程中螺(luo)絲松(song)動造成進(jin)(jin)相(xiang)(xiang)器(qi)(qi)不能(neng)正常工作。

2、準備好連接【主(zhu)電(dian)(dian)(dian)機(ji)轉子至進相(xiang)器(qi)接觸器(qi)KM13的(de)三根電(dian)(dian)(dian)纜(lan)(lan)】、【進相(xiang)器(qi)接觸器(qi)KM11至主(zhu)電(dian)(dian)(dian)機(ji)起動柜的(de)三根電(dian)(dian)(dian)纜(lan)(lan)】,其線徑應能承載主(zhu)電(dian)(dian)(dian)機(ji)轉子額定電(dian)(dian)(dian)流(liu),比好長度(du)并壓(ya)好接頭。

3、進相(xiang)器(qi)上的(de)電(dian)(dian)(dian)(dian)流(liu)表、功率(lv)因數表是直接(jie)從電(dian)(dian)(dian)(dian)機(ji)定子回路上的(de)電(dian)(dian)(dian)(dian)流(liu)互感(gan)(gan)器(qi)、電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)互感(gan)(gan)器(qi)取(qu)信號,要(yao)求所用電(dian)(dian)(dian)(dian)流(liu)互感(gan)(gan)器(qi)副邊的(de)額定電(dian)(dian)(dian)(dian)流(liu)為(wei)5A、電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)互感(gan)(gan)器(qi)副邊的(de)額定電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)為(wei)100V,若(ruo)用戶現用的(de)不滿(man)足該要(yao)求,則須另(ling)行準備符(fu)合上述(shu)要(yao)求的(de)互感(gan)(gan)器(qi)。(注:電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)互感(gan)(gan)器(qi)僅適用于高壓(ya)(ya)(ya)電(dian)(dian)(dian)(dian)機(ji),對低(di)壓(ya)(ya)(ya)電(dian)(dian)(dian)(dian)機(ji),進相(xiang)器(qi)電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)信號直接(jie)從定子回路取(qu))

4、新電機(ji)須帶上90%以上負載(zai)并正常運轉后才可(ke)調試進相器(qi)(qi),用戶(hu)在(zai)通(tong)知我方調試前,應調試好(hao)電機(ji)、減速機(ji)、磨(mo)機(ji)等(deng)其(qi)它設備,使其(qi)帶上負載(zai)正常運轉,以免(mian)延(yan)誤進相器(qi)(qi)調試時間。

5、各聯(lian)鎖線意(yi)義(yi)如(ru)下:

(225、227)取自電(dian)機(ji)起動柜星點短(duan)接接觸器(qi)的(de)輔(fu)助常開點,只有在電(dian)機(ji)起動完畢后,進相器(qi)才可(ke)以(yi)進相。

(355、357)當開關柜(ju)主開關是(shi)接觸器時與(yu)分閘按鈕并聯;是(shi)斷路器時與(yu)分閘按鈕串聯, 進相(xiang)狀態下主電機(ji)(ji)不能停(ting)機(ji)(ji),只(zhi)有先(xian)退(tui)相(xiang)才(cai)能停(ting)主機(ji)(ji)。

(359、361)串入開(kai)關柜(ju)合閘回(hui)路。當(dang)KM11吸合時,可以(yi)起(qi)動電機。

(363、369)從(cong)起動柜(ju)(ju)控制電(dian)(dian)源引(yin)單(dan)相380V,使KM11與起動柜(ju)(ju)控制回路(lu)同時得電(dian)(dian)。

(30、32)串入主(zhu)(zhu)電(dian)(dian)機電(dian)(dian)流(liu)計量(liang)回路(lu);(40、42)并(bing)入主(zhu)(zhu)電(dian)(dian)機電(dian)(dian)壓(ya)計量(liang)回路(lu)。(取(qu)(qu)A相(xiang)(xiang)電(dian)(dian)流(liu)則取(qu)(qu)B,C相(xiang)(xiang)電(dian)(dian)壓(ya),如(ru)此(ci)類推,電(dian)(dian)流(liu)和電(dian)(dian)壓(ya)不得取(qu)(qu)同相(xiang)(xiang))。

(A、B、C、N)接三相四線(xian)電源,導線(xian)橫截面積:TP600以(yi)下用4mm2;TP1000以(yi)下用6mm2;TP1500以(yi)下用10mm2。

6、控制器所有指(zhi)示燈的含義說(shuo)明如下:

(1)主板(中(zhong)間一塊)的(de)指示(shi)燈(從上(shang)往下(xia)數)

●L1、L2、L3:電(dian)(dian)機(ji)轉子三相電(dian)(dian)流信(xin)號指示(電(dian)(dian)機(ji)運轉時為循環顯示狀態(tai);自檢試驗時為隨(sui)機(ji)狀態(tai):或亮、或滅)

●L4:+5V電(dian)源指示(保持亮的狀態)

●L5:熱故障指示(有熱故障時L5滅)

●L6:缺相(xiang)及(ji)(ji)自動故(gu)障保護指(zhi)示(有缺相(xiang)故(gu)障及(ji)(ji)其(qi)它故(gu)障時L6燈滅(mie))

●L7:+15V電(dian)源指示(保持亮(liang)的狀態)

●L8:-15V電源(yuan)指示(保持(chi)亮的(de)狀態)

(2)驅動板(兩邊兩塊)

●分別(bie)代(dai)表12個(ge)可控制硅的觸發(fa)信號(指示燈均亮,并有規(gui)律的閃爍)

(二)試驗

1、檢查主電纜、聯鎖線、儀表線連(lian)接是否(fou)正確。

2、檢查各器件螺絲(si)是否緊固(gu)。

3、用萬(wan)用表測量(liang)可控硅(gui)極間電阻(zu):

●觸發極G與陰極K間電(dian)阻為幾十歐姆;

●觸發極(ji)G與陽極(ji)A間電(dian)阻(zu)大于(yu)幾十千歐;

●陰(yin)極K與(yu)陽(yang)極A間電(dian)阻大于幾十千歐(ou);

●陰極K與陽極A用萬用表200K檔測(ce)量,阻值應從(cong)小變化到無限大。

4、合上(shang)起動柜(ju)電(dian)源,進相器(qi)背面的接觸器(qi)KM11應吸合,短接225、227;合上(shang)進相器(qi)電(dian)源,電(dian)源指示燈亮;控(kong)制器(qi)應有電(dian),控(kong)制器(qi)上(shang)指示燈亮。

5、控(kong)制器上(shang)撥(bo)碼(ma)開關打在ON(上(shang)方(fang))位置,中間主板L1、L2、L3循環亮或滅,L4~L8全亮;兩邊兩塊驅動(dong)板指示燈閃爍(shuo)。

6、按綠色(se)進(jin)(jin)相按鈕,進(jin)(jin)相器(qi)前面(mian)的接觸(chu)器(qi)KM13吸合,延時后,背(bei)面(mian)的接觸(chu)器(qi)KM11斷開,綠色(se)進(jin)(jin)相指示燈亮,風機運轉,風應向上(shang)吹,主(zhu)變壓器(qi)副邊電流不超過30A,并且沒(mei)有大(da)幅度(du)變化。

7、按紅色(se)退(tui)相按鈕,進(jin)(jin)相器(qi)后(hou)面的接觸(chu)器(qi)KM11吸(xi)合,延時(shi)后(hou),前面的接觸(chu)器(qi)KM13斷開,綠色(se)進(jin)(jin)相指示燈(deng)滅,紅色(se)電源指示燈(deng)亮(liang),進(jin)(jin)相器(qi)即(ji)退(tui)出進(jin)(jin)相狀態。

8、通電(dian)試驗結束,請務必斷(duan)開(kai)225、227。

(三)調試

1、運行(xing)前(qian):控制器主板(ban)上撥碼開(kai)關應打在OFF(下(xia)方)位(wei)置。

2、起動(dong)主電機(ji):打(da)開進相器前柜(ju)門(men),合上(shang)空氣開關(guan),進相器電源接通,面板上(shang)的紅色(se)電源指示燈亮,關(guan)閉柜(ju)門(men),等待主機(ji)起動(dong)。

3、進相(xiang):(1)電機正常運(yun)轉(zhuan)后,按(an)綠(lv)色進相(xiang)按(an)鈕,進相(xiang)器(qi)前面(mian)的接觸器(qi)KM13吸合,延時后,背(bei)面(mian)的接觸器(qi)KM11斷開,綠(lv)色進相(xiang)指(zhi)示燈亮,風機運(yun)轉(zhuan),定子電流(liu)應下(xia)降,功率因數應上(shang)升。如果定子電流(liu)不下(xia)降反(fan)而(er)上(shang)升,調整同步變壓(ya)器(qi)上(shang)6V、6V0兩線(xian)的位置,再進相(xiang)。

(2)測量主變壓器原、副邊電流,應無(wu)大幅(fu)度擺(bai)動(dong)。

(3)電機(ji)定子電流應(ying)平穩,無大幅(fu)度擺(bai)動。

(4)六個電抗器上端銅(tong)排的電流(liu)擺動幅度(du)應一致。

4、退相(xiang)(xiang):按(an)紅色(se)退相(xiang)(xiang)按(an)鈕,進相(xiang)(xiang)器(qi)后面的(de)接(jie)觸器(qi)KM11吸合,延時(shi)后,前面的(de)接(jie)觸器(qi)KM13斷開,綠色(se)進相(xiang)(xiang)指(zhi)示燈滅,紅色(se)電源指(zhi)示燈亮(liang),進相(xiang)(xiang)器(qi)即退出進相(xiang)(xiang)狀態(tai)。

5、停(ting)(ting)車(che):進相器退(tui)相后(hou),按(an)(an)下主機(ji)(ji)停(ting)(ting)車(che)按(an)(an)鈕,電機(ji)(ji)即(ji)停(ting)(ting)車(che)。

(四)測量(liang)和觀察

1、測量可(ke)控(kong)硅、銅排、交流接觸(chu)器、電抗器、主變壓器、控(kong)制(zhi)板(ban)溫(wen)度。

2、測量可(ke)控硅觸發電(dian)(dian)壓;主變(bian)壓器一次(ci)、二次(ci)電(dian)(dian)流;電(dian)(dian)抗器輸入電(dian)(dian)流。

3、觀(guan)察風機運行情況。

4、觀察整(zheng)體運行情況,有無(wu)(wu)異常(chang)響聲或銅排(pai)有無(wu)(wu)大的抖(dou)動現象(xiang)等。

十(shi)使(shi)用維(wei)護

為(wei)確保TP系列靜止式進相器長(chang)期安全、可靠地運行(xing),請操作(zuo)人員(yuan)特(te)別注意以下事項:

1、嚴禁(jin)在進(jin)相器運行期間,切斷(duan)進(jin)相器外部(bu)電源。

2、定(ding)期檢查冷(leng)卻風(feng)機運轉(zhuan)狀(zhuang)況,冷(leng)卻風(feng)機停轉(zhuan)使可控硅(gui)散熱能(neng)力(li)下降,可能(neng)燒壞(huai)可控硅(gui)。

3、定(ding)期檢測主變壓器原、副邊運行電流。

4、定(ding)期檢測可(ke)控(kong)硅(gui)、聯(lian)接(jie)銅排、交流接(jie)觸器、電抗器、主變壓(ya)器、控(kong)制板的(de)溫度。

5、定(ding)期檢修主回路(lu)接(jie)觸器的觸頭。真空接(jie)觸器定(ding)期檢測(ce)絕緣(yuan)電阻(zu),用(yong)5KV或(huo)2.5KV搖表(biao)檢查,當開關管絕緣(yuan)電阻(zu)小于(yu)100兆歐時,應加強(qiang)監視,小于(yu)20兆歐時應立(li)即更(geng)換(huan)新(xin)管,以延長接(jie)觸器的使用(yong)壽命,保障進相器及電機(ji)安全(quan)運行。

6、當進相(xiang)器停用(yong)一段時間又重新啟用(yong)時, 次進相(xiang)前應(ying)觀察柜內控制單(dan)元(yuan)上各指示燈是否正常。電(dian)機起動并正常運轉后,各指示燈顯示如下:

·主(zhu)板(中間(jian)一塊):除L1,L2,L3周期性循環顯示外(注意:此指電機(ji)在(zai)運轉時的(de)狀(zhuang)態(tai),若電機(ji)未轉,該三燈為隨機(ji)狀(zhuang)態(tai)),其它(ta)各(ge)燈均亮。

·驅(qu)動扳(ban)(兩邊的(de)兩塊):其上面各指示(shi)燈均(jun)亮(liang)并(bing)有輕(qing)微閃爍。

7、當電機(ji)定子電流出現異(yi)常大幅擺動(dong)時,應立即退相,查(cha)出原因并檢(jian)修后投入使(shi)用。

8、定期(qi)打掃(sao)柜內(nei)衛生。

十一(yi)故(gu)障處理



主電機(ji)不能起動(dong)

端子363、369無380V 電源

檢查起動柜(ju)控制(zhi)電(dian)源

 

接觸器KM11不吸合

檢查KM11線包及其控制回路

 

接觸器KM11吸合,但其輔助觸點未閉合

檢修其輔助觸點

 

端子359、361串入合閘回路的線未接通

檢查該回(hui)路

不能投入進相

空氣開關QF1、QF2、QF3沒合上

合上空氣(qi)開(kai)關

 

按鈕STP、ST接觸不良

 

 

中間繼電器KA11觸點接觸不良

 

 

主電機起動柜內星點接觸器常開輔助觸點不能閉合(225、227未接通)

檢修該(gai)接(jie)觸(chu)器(qi)輔助觸(chu)點及連線

 

KM13不能(neng)吸合

檢查KM13線包及其控制回路

 

固態繼電器FV損壞或者不導通

控制器主控制板L6燈滅

檢查主控板7腳對11、12、13腳有無+、-3伏左右電壓,否則更換電流傳感器

 

 

檢查固態繼電器FV

FV的(de)3、4腳有(you)直流(liu)15V電(dian)壓,而323、325不(bu)通,須(xu)更換該繼電(dian)器(qi)

進相后主電(dian)機(ji)停機(ji)

接入開關柜的KM11、KM13的輔助觸點359、361接觸不好

維修該觸點

 

進相(xiang)器投(tou)入進相(xiang)瞬(shun)間外部(bu)空氣(qi)開關跳閘

更換大規(gui)格的空氣開關

進相后無效果

接入主控板的電流傳(chuan)感(gan)器(qi)信號(hao)線(xian)錯誤

電流傳感器從左到右TA1、TA2、TA3的信號線應分別對應與主控板的13、12、11腳

 

主控板的撥(bo)碼開關在自檢位

撥碼開關撥至工(gong)作位

 

KM13吸(xi)合后(hou)KM11未釋放(時間繼電器KT11壞)

更換KT11時間繼電器

 

KM15沒有(you)吸合

KM11的輔助觸點301、305接觸不良

維修該觸點

 

 

KM15線圈故障

更換KM15線圈

 

KM15主觸(chu)點(dian)接觸(chu)不良

更換KM15

 

主變壓(ya)器(qi)原邊開路

更換主(zhu)變壓器(qi)

進相(xiang)后主電機電流不(bu)減反(fan)增(zeng)

同(tong)步電(dian)源相序錯(cuo)誤

調換進相器內小變壓器TC上輸出6V、6V0電壓的兩線位置

 

電機轉速下(xia)降(缺相(xiang)),自動(dong)退(tui)相(xiang)

KM13主觸點(dian)接觸不良

維修該觸點

 

 

電機轉子線松動(dong),進相時的(de)電流沖擊導致缺相

檢查電機轉子線

進相后主電(dian)機電(dian)流擺(bai)動大

可控硅擊(ji)穿

測(ce)量可控硅極間(jian)電阻(zu)(詳細方法見調試部分)

 

觸發板損壞(huai)

測量可控硅控制極與陰極之間應有0.2V以上的直流電壓信號,否則應檢查觸發板

 

主板的撥(bo)碼(ma)開關在自檢位

撥碼(ma)開關撥至工作位

 

電機(ji)轉子(zi)線松動

檢查電機轉子線

 

KM13采用節能型線圈時,線圈故障導致KM13進行瞬間來回釋放、吸合,導致主回路接觸不良

維修或更換KM13線圈





注意:進相器檢修不得在(zai)進(jin)相(xiang)狀態下進(jin)行,發現問題應(ying)立即退相(xiang)。

十二(er)控制板(ban)檢修(xiu)



現象

原因

對策

L1L2L3不循環閃爍,L6滅,其它各燈正常

轉子(zi)缺相

檢查接觸器KM2主觸頭是否損壞,若損壞,則維修觸頭或更換接觸器

電流傳感器器損壞

檢查電流傳感器是否有±2V以上的輸出信號,否則更換傳感器

主控板(ban)元器件損壞(huai)

依次更換IC210IC211

L1L2L3不周期性閃爍,其它各燈正常

主控板元器件損壞

依次更換IC210IC211IC205IC207

L6滅,其它各燈正常

主(zhu)控板元器(qi)件損壞

依次更換IC207IC209

L5滅,其它各燈正常

散熱器溫度檢測回路故障(zhang)

檢查溫度開(kai)關及其連線

L4L7L8全部或部分滅

電源故障

1、檢查變壓器及控制板是否有±18V電源

2、更換相應的780578157915

F1-L1L6 F2-L1L6部分指示燈亮,主板各燈正常

觸發板元器件損(sun)壞

1、有一片ULN2004損壞,更換之

2、脈沖變壓器接觸不良,作相應處理

F1-L1L6 F2-L1L6指示燈全滅,主板各燈正常

觸(chu)發板元器件(jian)損壞

1、兩片ULN2004損壞,更換之

2、更換555芯片

觸發板無電源

1、檢查主板7815是否有虛焊

2、檢查觸發板19腳與主板6腳連接是否正常





十三注(zhu)意事項

1、進(jin)相器(qi)檢(jian)修應(ying)在退(tui)相狀態下進(jin)行(xing),發現問題應(ying)立即退(tui)相。

2、嚴禁(jin)隨意帶電插拔(ba)控制板,檢修控制板時,一定(ding)要把(ba)空開QF3打下來。

3、更換可(ke)(ke)控硅(gui)時應(ying)注(zhu)意陰、陽(yang)極的(de)(de)方向(xiang),并壓(ya)緊散熱(re)器(壓(ya)力不要過大),裝(zhuang)上后(hou)(hou)擰緊所有螺(luo)絲,之后(hou)(hou)再檢(jian)測可(ke)(ke)控硅(gui)各極間的(de)(de)電阻情況。若一(yi)只可(ke)(ke)控硅(gui)擊穿(chuan)(chuan)在柜體(ti)上直(zhi)接(jie)檢(jian)測,同一(yi)相的(de)(de)四(si)個可(ke)(ke)控硅(gui)均(jun)顯示擊穿(chuan)(chuan),此(ci)時應(ying)把該組(zu)可(ke)(ke)控硅(gui)間的(de)(de)聯接(jie)銅排拆掉再測 。

十四訂貨須知

1、提(ti)供電(dian)機型(xing)號、額定(ding)(ding)功率(lv)、定(ding)(ding)子電(dian)壓、定(ding)(ding)子電(dian)流、轉(zhuan)子電(dian)壓、轉(zhuan)子電(dian)流、額定(ding)(ding)功率(lv)因數(shu)。

2、提供電機拖(tuo)動負載的(de)特征(zheng)及負載率。

預知TP系列無環流靜止式進相器的更(geng)多信息,請撥打襄陽拓邦電氣(qi)官網電話: 鄭(zheng)經(jing)理(li)17771133316或(huo)咨(zi)詢網站客服!!

在線留言

LEAVE A MESSAGE