TP系列無環流靜止式進相器是襄(xiang)陽拓(tuo)邦(bang)電(dian)(dian)(dian)氣自選(xuan)研制開發(fa)的新一代(dai)高(gao)新技術產品,是一種專(zhuan)為(wei)大中(zhong)型(xing)繞線式(shi)異步電(dian)(dian)(dian)動機(ji)(ji)設(she)計制作的就地(di)無功功率補償裝置。它串接于電(dian)(dian)(dian)機(ji)(ji)轉(zhuan)子(zi)回路,改(gai)(gai)變轉(zhuan)子(zi)電(dian)(dian)(dian)流與(yu)轉(zhuan)子(zi)電(dian)(dian)(dian)壓(ya)的相位關(guan)系,通過磁場進而改(gai)(gai)變電(dian)(dian)(dian)機(ji)(ji)定子(zi)電(dian)(dian)(dian)流與(yu)電(dian)(dian)(dian)壓(ya)的相位關(guan)系,達到提高(gao)電(dian)(dian)(dian)機(ji)(ji)自身功率因(yin)數(shu)、降低電(dian)(dian)(dian)機(ji)(ji)定子(zi)電(dian)(dian)(dian)流和溫升的目的。這(zhe)種方式(shi)從根本上改(gai)(gai)善了電(dian)(dian)(dian)機(ji)(ji)的運行狀況(kuang),顯著降低電(dian)(dian)(dian)機(ji)(ji)及(ji)電(dian)(dian)(dian)網的無功損耗(hao),對(dui)節能降耗(hao)、降低單位產品成本,提高(gao)企(qi)業的經濟效益具有(you)重要的意(yi)義。
TP系列無(wu)環(huan)流靜止式進相器對無(wu)功(gong)功(gong)率的補(bu)償(chang)與電(dian)(dian)(dian)機(ji)定子側并聯電(dian)(dian)(dian)容(rong)(rong)器的補(bu)償(chang)有著本質的區(qu)別。電(dian)(dian)(dian)容(rong)(rong)補(bu)償(chang)只(zhi)是(shi)在(zai)電(dian)(dian)(dian)機(ji)之外(wai)的電(dian)(dian)(dian)網(wang)(wang)上對無(wu)功(gong)進行(xing)補(bu)償(chang),減少(shao)電(dian)(dian)(dian)網(wang)(wang)的無(wu)功(gong)輸(shu)入,電(dian)(dian)(dian)網(wang)(wang)的功(gong)率因數得(de)到提高,但是(shi)電(dian)(dian)(dian)機(ji)的無(wu)功(gong)消耗并沒有減少(shao),無(wu)法(fa)改善電(dian)(dian)(dian)機(ji)本身(shen)的運行(xing)狀(zhuang)況;而TP系列靜止式進相器是串(chuan)接在電(dian)機(ji)轉子回路中,不(bu)僅可顯著提高功率(lv)因數(shu),使電(dian)機(ji)定子電(dian)流大(da)幅度降低(di)(di),而且電(dian)機(ji)溫升明顯降低(di)(di),電(dian)機(ji)的效率(lv)和過載能力顯著提高。
TP系(xi)列(lie)靜(jing)止式進(jin)相(xiang)(xiang)器(qi)與自(zi)(zi)激(ji)(ji)(旋轉(zhuan))式進(jin)相(xiang)(xiang)機(ji)(ji)也不同。TP系(xi)列(lie)靜(jing)止式進(jin)相(xiang)(xiang)器(qi)采用(yong)了 的(de)(de)交-交變(bian)頻技術和微(wei)機(ji)(ji)、可(ke)控硅控制技術,可(ke)自(zi)(zi)動跟(gen)蹤電機(ji)(ji)運(yun)行狀(zhuang)態的(de)(de)變(bian)化(hua)并自(zi)(zi)動調整(zheng)相(xiang)(xiang)關參(can)數(shu)以達到佳的(de)(de)補償(chang)效果,這是自(zi)(zi)激(ji)(ji)式進(jin)相(xiang)(xiang)機(ji)(ji)無法(fa)做到的(de)(de)。而且,TP系(xi)列(lie)靜(jing)止式進(jin)相(xiang)(xiang)器(qi)從根本(ben)上克服了自(zi)(zi)激(ji)(ji)式進(jin)相(xiang)(xiang)機(ji)(ji)“整(zheng)流子”結構特別(bie)怕塵埃、壽(shou)命短(duan)、維修(xiu)頻繁的(de)(de)缺點(dian);具有參(can)數(shu)調節容(rong)易、主回路無轉(zhuan)動部件、不怕灰塵、可(ke)靠性高、使(shi)用(yong)壽(shou)命長、維護方(fang)便,是理想的(de)(de)取(qu)代(dai)自(zi)(zi)激(ji)(ji)式進(jin)相(xiang)(xiang)機(ji)(ji)的(de)(de)新型(xing)高科技產品。
TP系列靜止式進相器(qi)可(ke)廣泛用于水泥、化工、礦(kuang)山、冶金、鋼鐵、造紙、制(zhi)藥等行業(ye)的大(da)中型高低壓繞線式異步電機。
二型(xing)號命(ming)名
TP系列靜止式進相器型號命名方法如下:
型號(hao):TP-800,表示適用于額定轉(zhuan)子電流不超過800A的電機的靜(jing)止式進相器。
三(san)工作(zuo)原理
當電(dian)(dian)(dian)機(ji)(ji)(ji)運行進(jin)相(xiang)時,進(jin)相(xiang)器(qi)(qi)通(tong)過轉子(zi)(zi)電(dian)(dian)(dian)流(liu)傳感器(qi)(qi)采(cai)集到的(de)轉子(zi)(zi)電(dian)(dian)(dian)流(liu)信(xin)號(hao)及工頻電(dian)(dian)(dian)壓(ya)提供的(de)同步(bu)信(xin)號(hao)經微處理器(qi)(qi)CPU進(jin)行數據和相(xiang)位(wei)處理,控制可控硅的(de)觸發信(xin)號(hao),調(diao)整由(you)12只晶(jing)閘管組成的(de)交—交變頻裝置(zhi),將(jiang)降壓(ya)后的(de)工頻電(dian)(dian)(dian)源變為(wei)和轉子(zi)(zi)電(dian)(dian)(dian)流(liu)同頻率,相(xiang)位(wei)滯后90°的(de)附加(jia)電(dian)(dian)(dian)勢加(jia)在電(dian)(dian)(dian)機(ji)(ji)(ji)轉子(zi)(zi)回路中。轉子(zi)(zi)的(de)電(dian)(dian)(dian)流(liu)和電(dian)(dian)(dian)壓(ya)相(xiang)位(wei)因此改(gai)變,通(tong)過磁場進(jin)而改(gai)變電(dian)(dian)(dian)機(ji)(ji)(ji)定(ding)子(zi)(zi)電(dian)(dian)(dian)流(liu)與(yu)定(ding)子(zi)(zi)電(dian)(dian)(dian)壓(ya)的(de)相(xiang)位(wei)角,使電(dian)(dian)(dian)機(ji)(ji)(ji)的(de)功(gong)率因數提高,得到補償。
當電(dian)(dian)機(ji)在某一負載下運(yun)行時,其轉子電(dian)(dian)流(liu)為I2e、定子電(dian)(dian)流(liu)為I1e, 向量圖如下所示。
從電(dian)機(ji)學我們知道,激磁電(dian)流(liu)Im由(you)關系式Im=I1e-I2e,從向(xiang)量圖(tu)可得出Im。當進相器的(de)電(dian)勢(shi)疊(die)加在轉(zhuan)子回路后,轉(zhuan)子電(dian)流(liu)的(de)相位變(bian)為圖(tu)中(zhong)的(de)I2。由(you)于負(fu)載不變(bian),激磁電(dian)流(liu)Im不變(bian)。此時的(de)定子電(dian)流(liu)I1由(you)關系式I1=Im+I2從向(xiang)量圖(tu)可得出I1,如圖(tu)所(suo)示。從圖(tu)中(zhong)可以看出I1的(de)功(gong)率因數(shu)角(jiao)和幅值(zhi)都比I1e小,說明電(dian)機(ji)的(de)功(gong)率因數(shu)有所(suo)提高(gao),定子電(dian)流(liu)有所(suo)下降。
進(jin)相器就是(shi)這樣改變轉子電(dian)流(liu)(liu)與轉子電(dian)壓的(de)相位關系,通過磁場(chang)進(jin)而改變電(dian)機定子電(dian)流(liu)(liu)與定子電(dian)壓的(de)相位關系,減(jian)小功率因(yin)數角,終使(shi)電(dian)機本(ben)身(shen)的(de)功率因(yin)數得以(yi)提高(gao),定子電(dian)流(liu)(liu)得以(yi)下(xia)降,達到(dao)對電(dian)機補償(chang)的(de)目的(de)。
當負載發生改變時,微(wei)處理器(qi)實時檢測電機參數(shu)的(de)(de)變化,并根據負載的(de)(de)變化,動態調(diao)整附(fu)加在轉子(zi)上的(de)(de)電勢(shi)幅(fu)值,以使(shi)電機的(de)(de)功率(lv)因數(shu)始(shi)終(zhong)保(bao)持在期(qi)望(wang)值上。
四原理框圖
電容式補償的(de)矢量分析:
電容補償和進相器補償的原(yuan)理圖分別(bie)如(ru)下:
圖中,將(jiang)電(dian)機(ji)進行(xing)了等效簡(jian)化,R1、X1為(wei)電(dian)機(ji)定(ding)子(zi)等效電(dian)路的(de)電(dian)阻(zu)和電(dian)感,R2、X2為(wei)電(dian)機(ji)轉子(zi)等效電(dian)路的(de)電(dian)阻(zu)和電(dian)感,C為(wei)就地補償的(de)電(dian)容,Uf為(wei)進相器(qi)的(de)等效電(dian)路,M為(wei)電(dian)機(ji)的(de)接線點。
從圖可以看出,靜止式進(jin)(jin)相器和(he)電(dian)(dian)容補償對電(dian)(dian)機(ji)的(de)作用點(dian)不同,電(dian)(dian)容是在電(dian)(dian)機(ji)的(de)前(qian)端定(ding)子側進(jin)(jin)行補償,其補償范圍是在補償點(dian)的(de)前(qian)端;靜止式進(jin)(jin)相器串聯在電(dian)(dian)機(ji)的(de)后端,其補償范圍擴大到了電(dian)(dian)機(ji)。
五性能特(te)點
1、可(ke)使電機的功(gong)率因數提高(gao)到(dao)0.95以(yi)上,無功(gong)功(gong)率降低60%以(yi)上。
2、降低定子電流10%-20%。
3、降低線(xian)損、銅損20%-30%。
4、電機溫升降(jiang)低5%。
5、過(guo)載能力和效率大(da)大(da)提高,電機(ji)使用壽命(ming)延長。
6、具有(you)故障(zhang)自動保護功能,保障(zhang)設(she)備(bei)長(chang)期安(an)全運行。
7、操作簡單(dan),安裝調(diao)試和維修(xiu)保養均不影響(xiang)正常生產,半(ban)年內可收回成本。
六使(shi)用條件
1、安裝地點環境(jing)溫度≤40℃
2、安(an)裝地點相對濕度≤90%
3、 安裝地點無火災、爆炸危(wei)險品(pin),無化學腐蝕及劇烈振動。
4、海(hai)拔高度≤1500M。
5、進相(xiang)器(qi)柜(ju)體上方(fang)0.5米內(nei)應通風(feng);如無地溝,須將進相(xiang)器(qi)柜(ju)體架(jia)空0.1米。
注(zhu):TP系(xi)列(lie)靜止式進(jin)相器應(ying)滿足上方要(yao)求(qiu)的(de)使用條件,襄陽拓邦電氣還可提供適用于高原地區(qu)(海拔超過1500米)的靜止式進相器(但用戶(hu)須事(shi)先特別申請)。
七技術參數(shu)
進 相 器 型 號 |
適 配 電 機 參 數 |
|
額定轉子電流(A) |
額定功率(KW) |
|
TP-400 |
≤400 |
95-800 |
TP-500 |
400-500 |
245-1000 |
TP-600 |
500-600 |
315-1250 |
TP-800 |
600-800 |
630-1600 |
TP-1000 |
800-1000 |
1000-2000 |
TP-1200 |
1000-1200 |
1600-2500 |
TP-1500 |
1200-1500 |
2000以上 |
八(ba)安裝尺寸(cun)
1、外型尺(chi)寸圖
2、安裝基礎(chu)圖(tu)
3、規(gui)格尺寸表
型號 |
外形尺寸(MM) |
安裝尺寸(MM) |
||||
寬(W) |
深(D) |
高(H) |
寬(E) |
深(F) |
螺孔 |
|
TP400-600 |
1000 |
760 |
2000 |
780 |
620 |
14 |
TP800-1000 |
1100 |
800 |
2000 |
880 |
650 |
14 |
TP1200-1500 |
1200 |
900 |
2200 |
980 |
750 |
16 |
注:隨著產(chan)品不(bu)斷(duan)更(geng)新換代,外形及安裝尺寸(cun)會有(you)所(suo)變化,請以具體的產(chan)品為準。
九安裝調試
(一)安裝
1、將進相(xiang)(xiang)(xiang)器(qi)搬到安(an)裝位置,注意進相(xiang)(xiang)(xiang)器(qi)柜體(ti)底部(bu)應與地溝相(xiang)(xiang)(xiang)通或架空,首先是打開柜子的前(qian)后(hou)門,從上到下(xia),逐一地擰緊(jin)螺絲,防止在運輸(shu)過程中螺絲松動造(zao)成進相(xiang)(xiang)(xiang)器(qi)不能正常工作。
2、準備好連接【主(zhu)電機轉子(zi)至(zhi)進相器接觸器KM13的三根電纜(lan)】、【進相器接觸器KM11至(zhi)主(zhu)電機起動柜的三根電纜(lan)】,其線徑(jing)應能承載主(zhu)電機轉子(zi)額定電流,比好長度并壓好接頭(tou)。
3、進(jin)相器上的(de)(de)電(dian)(dian)(dian)流表、功率因數表是直接(jie)從(cong)電(dian)(dian)(dian)機(ji)(ji)定子(zi)回路(lu)上的(de)(de)電(dian)(dian)(dian)流互感器、電(dian)(dian)(dian)壓(ya)(ya)互感器取(qu)(qu)信(xin)號(hao),要(yao)(yao)求所(suo)用(yong)電(dian)(dian)(dian)流互感器副(fu)邊(bian)的(de)(de)額定電(dian)(dian)(dian)流為(wei)5A、電(dian)(dian)(dian)壓(ya)(ya)互感器副(fu)邊(bian)的(de)(de)額定電(dian)(dian)(dian)壓(ya)(ya)為(wei)100V,若用(yong)戶現用(yong)的(de)(de)不滿足該(gai)要(yao)(yao)求,則須(xu)另行(xing)準備符合上述要(yao)(yao)求的(de)(de)互感器。(注:電(dian)(dian)(dian)壓(ya)(ya)互感器僅適用(yong)于高壓(ya)(ya)電(dian)(dian)(dian)機(ji)(ji),對低壓(ya)(ya)電(dian)(dian)(dian)機(ji)(ji),進(jin)相器電(dian)(dian)(dian)壓(ya)(ya)信(xin)號(hao)直接(jie)從(cong)定子(zi)回路(lu)取(qu)(qu))
4、新電機須帶(dai)上(shang)(shang)90%以上(shang)(shang)負載并正常(chang)運轉后才可調(diao)試進相(xiang)器(qi),用戶在(zai)通知我方調(diao)試前,應調(diao)試好電機、減速機、磨機等其它設備,使其帶(dai)上(shang)(shang)負載正常(chang)運轉,以免延誤進相(xiang)器(qi)調(diao)試時間。
5、各聯鎖線意義如下:
(225、227)取自電機起動(dong)柜星點短接接觸器的(de)輔(fu)助常開(kai)點,只有在電機起動(dong)完畢后,進相(xiang)器才(cai)可(ke)以進相(xiang)。
(355、357)當開(kai)關(guan)柜主開(kai)關(guan)是(shi)接觸器時(shi)與分閘按鈕并聯(lian);是(shi)斷(duan)路器時(shi)與分閘按鈕串聯(lian), 進相狀態下主電機(ji)不能停機(ji),只有先(xian)退相才能停主機(ji)。
(359、361)串入開關柜(ju)合閘回路。當KM11吸合時,可以起(qi)動電機。
(363、369)從起動柜(ju)控制電(dian)源引單相380V,使KM11與起動柜(ju)控制回路同(tong)時(shi)得(de)電(dian)。
(30、32)串入(ru)主(zhu)電(dian)(dian)機電(dian)(dian)流計(ji)(ji)量回路;(40、42)并入(ru)主(zhu)電(dian)(dian)機電(dian)(dian)壓計(ji)(ji)量回路。(取A相電(dian)(dian)流則取B,C相電(dian)(dian)壓,如此類推(tui),電(dian)(dian)流和電(dian)(dian)壓不得取同相)。
(A、B、C、N)接(jie)三相(xiang)四線電源,導線橫截面積:TP600以(yi)下用(yong)4mm2;TP1000以(yi)下用(yong)6mm2;TP1500以(yi)下用(yong)10mm2。
6、控制器(qi)所有指示燈(deng)的含義說明如下:
(1)主板(中間一(yi)塊(kuai))的指示燈(從上往(wang)下(xia)數)
●L1、L2、L3:電機(ji)轉(zhuan)子(zi)三相電流信號指示(電機(ji)運轉(zhuan)時(shi)為(wei)循環顯示狀態;自(zi)檢試驗時(shi)為(wei)隨(sui)機(ji)狀態:或(huo)亮、或(huo)滅)
●L4:+5V電源指示(保持亮的狀態)
●L5:熱故(gu)障(zhang)指示(shi)(有(you)熱故(gu)障(zhang)時L5滅(mie))
●L6:缺相及自動故障保(bao)護(hu)指示(有(you)缺相故障及其它(ta)故障時L6燈滅)
●L7:+15V電源指示(保持(chi)亮的狀(zhuang)態(tai))
●L8:-15V電源指示(保持亮的狀態)
(2)驅動板(兩邊兩塊)
●分(fen)別代表12個(ge)可控制硅(gui)的觸發信號(指示燈均(jun)亮,并有規律(lv)的閃爍)
(二)試驗
1、檢查主電纜(lan)、聯鎖(suo)線、儀表線連接是否正(zheng)確(que)。
2、檢查各(ge)器件螺絲(si)是(shi)否緊(jin)固。
3、用萬用表(biao)測量可控硅極間電阻:
●觸(chu)發極G與(yu)陰極K間電阻(zu)為幾十歐姆;
●觸發極G與(yu)陽極A間(jian)電阻大于(yu)幾十千歐(ou);
●陰極K與陽極A間(jian)電阻大于(yu)幾十千(qian)歐(ou);
●陰極K與陽極A用萬用表200K檔測量,阻值應從(cong)小(xiao)變化(hua)到無限大。
4、合(he)(he)上(shang)起動柜電源(yuan),進相器背(bei)面的接(jie)觸(chu)器KM11應吸合(he)(he),短接(jie)225、227;合(he)(he)上(shang)進相器電源(yuan),電源(yuan)指(zhi)示(shi)燈(deng)亮;控(kong)制器應有(you)電,控(kong)制器上(shang)指(zhi)示(shi)燈(deng)亮。
5、控制器上撥碼開關打在ON(上方)位置(zhi),中間主板(ban)L1、L2、L3循環亮(liang)或滅,L4~L8全亮(liang);兩(liang)邊兩(liang)塊驅動(dong)板(ban)指示燈(deng)閃爍。
6、按(an)綠色進相按(an)鈕,進相器(qi)(qi)前(qian)面的(de)接觸(chu)器(qi)(qi)KM13吸合(he),延時(shi)后,背面的(de)接觸(chu)器(qi)(qi)KM11斷開,綠色進相指示燈(deng)亮,風(feng)機運轉,風(feng)應向上吹,主變(bian)壓器(qi)(qi)副邊電流不超過30A,并且沒(mei)有(you)大幅度變(bian)化(hua)。
7、按紅色退(tui)(tui)相(xiang)按鈕,進相(xiang)器(qi)后面(mian)的接(jie)(jie)觸(chu)器(qi)KM11吸(xi)合,延(yan)時(shi)后,前面(mian)的接(jie)(jie)觸(chu)器(qi)KM13斷(duan)開,綠色進相(xiang)指示燈滅,紅色電源指示燈亮,進相(xiang)器(qi)即退(tui)(tui)出(chu)進相(xiang)狀態(tai)。
8、通(tong)電試驗結(jie)束(shu),請務必(bi)斷開225、227。
(三)調試
1、運行前:控制器主(zhu)板上撥碼(ma)開關應打在(zai)OFF(下方)位置(zhi)。
2、起動主電(dian)機:打開(kai)進相器前柜門,合上空氣開(kai)關,進相器電(dian)源接(jie)通,面板上的紅色電(dian)源指示燈亮,關閉柜門,等(deng)待主機起動。
3、進(jin)相(xiang):(1)電(dian)機(ji)正常運轉(zhuan)(zhuan)后(hou),按綠(lv)色進(jin)相(xiang)按鈕(niu),進(jin)相(xiang)器(qi)前面的接(jie)觸器(qi)KM13吸合(he),延時后(hou),背面的接(jie)觸器(qi)KM11斷開,綠(lv)色進(jin)相(xiang)指示(shi)燈(deng)亮,風機(ji)運轉(zhuan)(zhuan),定子(zi)(zi)電(dian)流應下(xia)(xia)降(jiang),功(gong)率(lv)因數應上升。如果(guo)定子(zi)(zi)電(dian)流不下(xia)(xia)降(jiang)反而上升,調整(zheng)同步變(bian)壓器(qi)上6V、6V0兩線的位(wei)置(zhi),再進(jin)相(xiang)。
(2)測(ce)量主變(bian)壓器原、副邊電流,應無大幅度擺動(dong)。
(3)電(dian)機定子電(dian)流應平穩,無大(da)幅度擺(bai)動。
(4)六(liu)個電抗器上端銅排的電流擺動幅度應一(yi)致。
4、退(tui)相(xiang)(xiang):按紅色退(tui)相(xiang)(xiang)按鈕,進(jin)相(xiang)(xiang)器(qi)后(hou)面(mian)的接觸器(qi)KM11吸合,延(yan)時(shi)后(hou),前面(mian)的接觸器(qi)KM13斷開,綠色進(jin)相(xiang)(xiang)指示燈滅,紅色電源指示燈亮,進(jin)相(xiang)(xiang)器(qi)即退(tui)出進(jin)相(xiang)(xiang)狀態(tai)。
5、停(ting)(ting)車:進相(xiang)器(qi)退相(xiang)后,按下主機停(ting)(ting)車按鈕(niu),電機即停(ting)(ting)車。
(四)測量和觀察
1、測量可(ke)控硅、銅(tong)排(pai)、交(jiao)流接觸器、電抗(kang)器、主變壓器、控制板(ban)溫度。
2、測量可控(kong)硅觸(chu)發電(dian)壓(ya);主(zhu)變壓(ya)器(qi)一次(ci)、二次(ci)電(dian)流;電(dian)抗器(qi)輸(shu)入電(dian)流。
3、觀察風(feng)機(ji)運行情況。
4、觀察(cha)整體運行情況,有(you)無異常響聲或(huo)銅排有(you)無大的抖(dou)動現象等。
十使用(yong)維護
為確保(bao)TP系列靜止式進相器長(chang)期(qi)安全、可靠地運行,請(qing)操作(zuo)人員(yuan)特別(bie)注意以(yi)下事項:
1、嚴禁在(zai)進相器(qi)運行期間,切斷進相器(qi)外部(bu)電源(yuan)。
2、定期檢查(cha)冷(leng)卻(que)風機運(yun)轉狀(zhuang)況,冷(leng)卻(que)風機停轉使可(ke)控(kong)硅(gui)散熱能力下降,可(ke)能燒壞可(ke)控(kong)硅(gui)。
3、定(ding)期檢測主(zhu)變壓(ya)器(qi)原、副(fu)邊運行電流。
4、定期檢測(ce)可控(kong)硅、聯接銅排、交(jiao)流接觸器、電抗器、主變(bian)壓器、控(kong)制板的溫度。
5、定(ding)期(qi)檢修主(zhu)回路接觸(chu)(chu)器的(de)觸(chu)(chu)頭。真空(kong)接觸(chu)(chu)器定(ding)期(qi)檢測絕緣電阻,用(yong)5KV或2.5KV搖表檢查,當(dang)開關(guan)管(guan)(guan)絕緣電阻小于100兆歐時,應(ying)加強(qiang)監視,小于20兆歐時應(ying)立即更換(huan)新(xin)管(guan)(guan),以延長(chang)接觸(chu)(chu)器的(de)使(shi)用(yong)壽命,保(bao)障進相器及電機安全運行(xing)。
6、當(dang)進(jin)相器停用一段時間(jian)又重新啟(qi)用時, 次(ci)進(jin)相前應觀察柜(ju)內控制單元上(shang)各指示(shi)燈是否正常。電機(ji)起動(dong)并正常運轉后,各指示(shi)燈顯示(shi)如(ru)下(xia):
·主板(中間一塊):除L1,L2,L3周期性循環(huan)顯示外(注(zhu)意:此指(zhi)電(dian)機在運轉時的狀(zhuang)態(tai),若電(dian)機未(wei)轉,該三燈(deng)為隨機狀(zhuang)態(tai)),其(qi)它(ta)各(ge)燈(deng)均亮。
·驅(qu)動扳(兩邊的兩塊):其上面各指示燈均亮并有輕微(wei)閃爍(shuo)。
7、當電(dian)機定子電(dian)流(liu)出現(xian)異(yi)常大(da)幅擺動時,應(ying)立即退(tui)相,查出原因并檢修(xiu)后(hou)投入使用。
8、定期(qi)打掃(sao)柜內衛生。
十一(yi)故障處理
主電機不能(neng)起(qi)動 |
端子363、369無380V 電源 |
檢查起動柜(ju)控制電源(yuan) |
||
|
接觸器KM11不吸合 |
檢查KM11線包及其控制回路 |
||
|
接觸器KM11吸合,但其輔助觸點未閉合 |
檢修其輔助觸點 |
||
|
端子359、361串入合閘回路的線未接通 |
檢查該回路 |
||
不能投入進相 |
空氣開關QF1、QF2、QF3沒合上 |
合上空氣開關 |
||
|
按鈕STP、ST接觸不良 |
|
||
|
中間繼電器KA11觸點接觸不良 |
|
||
|
主電機起動柜內星點接觸器常開輔助觸點不能閉合(225、227未接通) |
檢修該接(jie)觸(chu)器輔(fu)助觸(chu)點及連(lian)線 |
||
|
KM13不(bu)能吸合 |
檢查KM13線包及其控制回路 |
||
|
固態繼電器FV損壞或者不導通 |
控制器主控制板L6燈滅 |
檢查主控板7腳對11、12、13腳有無+、-3伏左右電壓,否則更換電流傳感器 |
|
|
|
檢查固態繼電器FV |
FV的3、4腳有直流15V電(dian)壓(ya),而323、325不通,須更(geng)換該繼電(dian)器 |
|
進相后主電機(ji)停機(ji) |
接入開關柜的KM11、KM13的輔助觸點359、361接觸不好 |
維修該觸點 |
||
|
進相(xiang)器(qi)投入進相(xiang)瞬(shun)間(jian)外部空氣開關(guan)跳閘 |
更換(huan)大規格的(de)空氣(qi)開(kai)關 |
||
進(jin)相后(hou)無(wu)效果 |
接入主(zhu)控板的電流傳感器信號線(xian)錯誤(wu) |
電流傳感器從左到右TA1、TA2、TA3的信號線應分別對應與主控板的13、12、11腳 |
||
|
主(zhu)控板的(de)撥碼開關在自檢位(wei) |
撥(bo)碼開(kai)關撥(bo)至(zhi)工作位 |
||
|
KM13吸合(he)后KM11未釋放(時間繼電器KT11壞) |
更換KT11時間繼電器 |
||
|
KM15沒有吸合 |
KM11的輔助觸點301、305接觸不良 |
維修該(gai)觸(chu)點 |
|
|
|
KM15線圈故障 |
更換KM15線圈 |
|
|
KM15主(zhu)觸點接觸不良 |
更換KM15 |
||
|
主(zhu)變(bian)壓器(qi)原(yuan)邊開路 |
更換主變壓器 |
||
進相后主電機電流(liu)不減反增 |
同步電源相序錯誤 |
調換進相器內小變壓器TC上輸出6V、6V0電壓的兩線位置 |
||
|
電機轉速下降(jiang)(缺(que)相),自(zi)動退相 |
KM13主觸點接觸不良 |
維(wei)修該(gai)觸點 |
|
|
|
電(dian)機(ji)轉子線松動,進相(xiang)時的電(dian)流沖擊(ji)導致缺相(xiang) |
檢查電機轉子線 |
|
進相后主電機電流擺動大 |
可(ke)控硅擊穿 |
測量可控硅極間電阻(詳細方(fang)法見調試(shi)部分) |
||
|
觸發板損(sun)壞(huai) |
測量可控硅控制極與陰極之間應有0.2V以上的直流電壓信號,否則應檢查觸發板 |
||
|
主(zhu)板的(de)撥碼開關(guan)在(zai)自檢位 |
撥(bo)碼開關撥(bo)至工作位 |
||
|
電機轉子線(xian)松(song)動 |
檢查電機轉子線 |
||
|
當KM13采用節能型線圈時,線圈故障導致KM13進行瞬間來回釋放、吸合,導致主回路接觸不良 |
維修或更換KM13線圈 |
注意(yi):進相器檢修不得在進(jin)相(xiang)狀態(tai)下進(jin)行,發現問題(ti)應(ying)立即退相(xiang)。
十二(er)控制板檢(jian)修
現象 |
原(yuan)因 |
對策 |
L1、L2、L3不循環閃爍,L6滅,其它各燈正常 |
轉(zhuan)子缺相(xiang) |
檢查接觸器KM2主觸頭是否損壞,若損壞,則維修觸頭或更換接觸器 |
電(dian)流傳(chuan)感器器損壞 |
檢查電流傳感器是否有±2V以上的輸出信號,否則更換傳感器 |
|
主控板元器件損(sun)壞 |
依次更換IC210、IC211 |
|
L1、L2、L3不周期性閃爍,其它各燈正常 |
主控(kong)板元器件損壞 |
依次更換IC210、IC211、IC205、IC207 |
L6滅,其它各燈正常 |
主控板元器件(jian)損(sun)壞 |
依次更換IC207、IC209 |
L5滅,其它各燈正常 |
散熱器溫度(du)檢測回路(lu)故障 |
檢查(cha)溫度(du)開關及(ji)其連(lian)線(xian) |
L4、L7、L8全部或部分滅 |
電源(yuan)故障 |
1、檢查變壓器及控制板是否有±18V電源 2、更換相應的7805、7815、7915 |
F1-L1~L6 或F2-L1~L6部分指示燈亮,主板各燈正常 |
觸發板元器件(jian)損壞 |
1、有一片ULN2004損壞,更換之 2、脈沖變壓器接觸不良,作相應處理 |
F1-L1~L6 或F2-L1~L6指示燈全滅,主板各燈正常 |
觸發板元器(qi)件損壞 |
1、兩片ULN2004損壞,更換之 2、更換555芯片 |
觸發板無電源 |
1、檢查主板7815是否有虛焊 2、檢查觸發板19腳與主板6腳連接是否正常 |
十(shi)三注意事項(xiang)
1、進(jin)相器(qi)檢修應在退相狀態下(xia)進(jin)行,發現(xian)問題應立即退相。
2、嚴禁隨意帶電(dian)插拔控(kong)制板,檢修控(kong)制板時,一定要(yao)把空開(kai)QF3打下來。
3、更換可(ke)控硅(gui)時(shi)應(ying)注意陰(yin)、陽極的(de)方向(xiang),并壓(ya)緊(jin)散(san)熱(re)器(壓(ya)力不(bu)要過大),裝上(shang)后擰緊(jin)所有螺絲,之后再檢(jian)測可(ke)控硅(gui)各極間的(de)電(dian)阻情況。若一只可(ke)控硅(gui)擊穿在(zai)柜(ju)體上(shang)直接檢(jian)測,同一相的(de)四個可(ke)控硅(gui)均顯示擊穿,此時(shi)應(ying)把(ba)該組可(ke)控硅(gui)間的(de)聯接銅排拆掉再測 。
十(shi)四訂貨須知
1、提供(gong)電(dian)(dian)機型號、額定(ding)(ding)功率(lv)、定(ding)(ding)子電(dian)(dian)壓、定(ding)(ding)子電(dian)(dian)流(liu)(liu)、轉子電(dian)(dian)壓、轉子電(dian)(dian)流(liu)(liu)、額定(ding)(ding)功率(lv)因數。
2、提(ti)供電機拖動負載的特(te)征(zheng)及負載率。
預知TP系列無環流靜止式進相器的更多信息,請撥打襄陽拓邦電氣官網電話: 鄭經理17771133316或咨(zi)詢網站(zhan)客(ke)服(fu)!!