欧美最猛性XXXXX69交_亚洲精品无码永久电影在线_欧美黑人粗大xxxxbbbb_中文字幕日韩精品有码视频

遼陽產品中心
遼陽產品中心

遼陽產品中心

product

遼陽TP系列靜止式進相器

一概述TP系列(lie)無環(huan)流靜止式(shi)進相器是襄陽(yang)拓邦(bang)電氣自選研制開發的新一代高新技(ji)術(shu)產品,是一種(zhong)專為大(da)中型繞線(xian)式(shi)異……

相關內容
在線留言
詳情內容
content details

TP系列無環流靜止式進相器是襄(xiang)陽拓(tuo)邦電(dian)(dian)(dian)氣自(zi)選研制開(kai)發的(de)(de)(de)(de)新一(yi)代(dai)高(gao)新技術產(chan)品(pin)(pin),是一(yi)種專為(wei)大中(zhong)型繞線式異步電(dian)(dian)(dian)動(dong)機(ji)設計制作的(de)(de)(de)(de)就(jiu)地無功(gong)(gong)功(gong)(gong)率補償裝置。它串接(jie)于電(dian)(dian)(dian)機(ji)轉子回(hui)路,改變轉子電(dian)(dian)(dian)流(liu)與(yu)轉子電(dian)(dian)(dian)壓的(de)(de)(de)(de)相位(wei)(wei)關(guan)系(xi)(xi),通過磁場進(jin)而(er)改變電(dian)(dian)(dian)機(ji)定子電(dian)(dian)(dian)流(liu)與(yu)電(dian)(dian)(dian)壓的(de)(de)(de)(de)相位(wei)(wei)關(guan)系(xi)(xi),達到提高(gao)電(dian)(dian)(dian)機(ji)自(zi)身(shen)功(gong)(gong)率因數(shu)、降低(di)電(dian)(dian)(dian)機(ji)定子電(dian)(dian)(dian)流(liu)和溫(wen)升的(de)(de)(de)(de)目的(de)(de)(de)(de)。這種方式從根本上改善了電(dian)(dian)(dian)機(ji)的(de)(de)(de)(de)運行狀況,顯著(zhu)降低(di)電(dian)(dian)(dian)機(ji)及電(dian)(dian)(dian)網的(de)(de)(de)(de)無功(gong)(gong)損(sun)耗,對節能降耗、降低(di)單位(wei)(wei)產(chan)品(pin)(pin)成本,提高(gao)企業(ye)的(de)(de)(de)(de)經濟效(xiao)益具有(you)重(zhong)要的(de)(de)(de)(de)意義。


TP系(xi)列無(wu)環流靜止(zhi)式進相器對無(wu)功(gong)功(gong)率(lv)的(de)(de)(de)補償(chang)(chang)(chang)與電(dian)(dian)(dian)機定子側并聯電(dian)(dian)(dian)容器的(de)(de)(de)補償(chang)(chang)(chang)有(you)(you)著本質的(de)(de)(de)區別(bie)。電(dian)(dian)(dian)容補償(chang)(chang)(chang)只是(shi)在電(dian)(dian)(dian)機之外的(de)(de)(de)電(dian)(dian)(dian)網上(shang)對無(wu)功(gong)進行補償(chang)(chang)(chang),減(jian)少電(dian)(dian)(dian)網的(de)(de)(de)無(wu)功(gong)輸入,電(dian)(dian)(dian)網的(de)(de)(de)功(gong)率(lv)因數得到提高,但是(shi)電(dian)(dian)(dian)機的(de)(de)(de)無(wu)功(gong)消耗并沒有(you)(you)減(jian)少,無(wu)法改善電(dian)(dian)(dian)機本身(shen)的(de)(de)(de)運行狀況;而TP系列靜止式進相器是(shi)串接在(zai)電(dian)(dian)機(ji)轉子回路(lu)中,不僅(jin)可顯著提(ti)高功率因數,使電(dian)(dian)機(ji)定子電(dian)(dian)流大幅(fu)度降(jiang)低,而且電(dian)(dian)機(ji)溫升明顯降(jiang)低,電(dian)(dian)機(ji)的效率和過載(zai)能(neng)力顯著提(ti)高。

TP系(xi)列(lie)靜止(zhi)式(shi)(shi)進(jin)(jin)相(xiang)器與自激(ji)(旋(xuan)轉)式(shi)(shi)進(jin)(jin)相(xiang)機(ji)也不(bu)同。TP系(xi)列(lie)靜止(zhi)式(shi)(shi)進(jin)(jin)相(xiang)器采用了 的交-交變(bian)頻技術和微(wei)機(ji)、可控(kong)硅控(kong)制技術,可自動(dong)跟蹤電機(ji)運行狀態(tai)的變(bian)化并自動(dong)調(diao)整相(xiang)關參(can)數以達到(dao)佳的補償效果,這是(shi)自激(ji)式(shi)(shi)進(jin)(jin)相(xiang)機(ji)無法做到(dao)的。而且,TP系(xi)列(lie)靜止(zhi)式(shi)(shi)進(jin)(jin)相(xiang)器從根本(ben)上克服了自激(ji)式(shi)(shi)進(jin)(jin)相(xiang)機(ji)“整流子”結構(gou)特別怕塵埃、壽(shou)命短、維修頻繁的缺點;具(ju)有參(can)數調(diao)節容易、主(zhu)回路(lu)無轉動(dong)部件、不(bu)怕灰塵、可靠性高、使用壽(shou)命長、維護方便,是(shi)理想的取代(dai)自激(ji)式(shi)(shi)進(jin)(jin)相(xiang)機(ji)的新型高科技產品。

TP系列靜止(zhi)式進(jin)相器可(ke)廣泛用于水泥、化(hua)工、礦山、冶(ye)金(jin)、鋼鐵、造紙、制藥(yao)等行業的大中型高低壓(ya)繞線式異(yi)步電機。


二型號(hao)命名

TP系列靜止式進相器型號命名方法如下(xia):





型(xing)號:TP-800,表示適用于額定轉(zhuan)子(zi)電流不超過800A的電機的靜止式進相器。


三工作原理

當電(dian)(dian)(dian)機運行(xing)進相(xiang)(xiang)(xiang)時,進相(xiang)(xiang)(xiang)器(qi)通(tong)過(guo)轉子電(dian)(dian)(dian)流(liu)傳(chuan)感器(qi)采集到(dao)的(de)(de)(de)(de)轉子電(dian)(dian)(dian)流(liu)信號及工頻(pin)電(dian)(dian)(dian)壓提供的(de)(de)(de)(de)同步(bu)信號經微處(chu)理器(qi)CPU進行(xing)數據和(he)相(xiang)(xiang)(xiang)位(wei)(wei)處(chu)理,控制可控硅的(de)(de)(de)(de)觸發信號,調整由12只(zhi)晶閘(zha)管組成的(de)(de)(de)(de)交—交變(bian)頻(pin)裝(zhuang)置,將降壓后(hou)的(de)(de)(de)(de)工頻(pin)電(dian)(dian)(dian)源變(bian)為和(he)轉子電(dian)(dian)(dian)流(liu)同頻(pin)率,相(xiang)(xiang)(xiang)位(wei)(wei)滯后(hou)90°的(de)(de)(de)(de)附加電(dian)(dian)(dian)勢加在電(dian)(dian)(dian)機轉子回路中(zhong)。轉子的(de)(de)(de)(de)電(dian)(dian)(dian)流(liu)和(he)電(dian)(dian)(dian)壓相(xiang)(xiang)(xiang)位(wei)(wei)因此(ci)改(gai)變(bian),通(tong)過(guo)磁(ci)場進而改(gai)變(bian)電(dian)(dian)(dian)機定(ding)(ding)子電(dian)(dian)(dian)流(liu)與定(ding)(ding)子電(dian)(dian)(dian)壓的(de)(de)(de)(de)相(xiang)(xiang)(xiang)位(wei)(wei)角(jiao),使電(dian)(dian)(dian)機的(de)(de)(de)(de)功(gong)率因數提高,得到(dao)補(bu)償。

當(dang)電(dian)機(ji)在某一負載下運行時(shi),其轉子電(dian)流為I2e、定子電(dian)流為I1e, 向(xiang)量(liang)圖(tu)如下所(suo)示。







從電(dian)(dian)機(ji)學我們(men)知道,激磁電(dian)(dian)流Im由(you)關系式Im=I1e-I2e,從向量圖(tu)(tu)(tu)(tu)可得出(chu)Im。當(dang)進相器的(de)電(dian)(dian)勢疊(die)加(jia)在(zai)轉(zhuan)子(zi)回路(lu)后,轉(zhuan)子(zi)電(dian)(dian)流的(de)相位變為(wei)圖(tu)(tu)(tu)(tu)中的(de)I2。由(you)于負載(zai)不(bu)變,激磁電(dian)(dian)流Im不(bu)變。此時的(de)定子(zi)電(dian)(dian)流I1由(you)關系式I1=Im+I2從向量圖(tu)(tu)(tu)(tu)可得出(chu)I1,如圖(tu)(tu)(tu)(tu)所示。從圖(tu)(tu)(tu)(tu)中可以(yi)看出(chu)I1的(de)功率因(yin)數角和幅值都比I1e小,說明電(dian)(dian)機(ji)的(de)功率因(yin)數有所提高(gao),定子(zi)電(dian)(dian)流有所下降。

進相器就是這樣改(gai)變轉子(zi)電(dian)(dian)流與(yu)轉子(zi)電(dian)(dian)壓(ya)的相位(wei)關系(xi),通(tong)過磁(ci)場(chang)進而改(gai)變電(dian)(dian)機(ji)定(ding)子(zi)電(dian)(dian)流與(yu)定(ding)子(zi)電(dian)(dian)壓(ya)的相位(wei)關系(xi),減小功率(lv)因(yin)(yin)數角,終使電(dian)(dian)機(ji)本身的功率(lv)因(yin)(yin)數得(de)以提高,定(ding)子(zi)電(dian)(dian)流得(de)以下降,達到(dao)對電(dian)(dian)機(ji)補償(chang)的目的。

當(dang)負(fu)(fu)載(zai)發生(sheng)改變時(shi),微處理器實時(shi)檢測電機參數(shu)的變化,并根(gen)據負(fu)(fu)載(zai)的變化,動態調(diao)整(zheng)附加在轉(zhuan)子上的電勢(shi)幅值,以(yi)使電機的功率(lv)因數(shu)始(shi)終保持在期望值上。

四原理框圖(tu)






電(dian)容式補償的矢量分析:








電(dian)容(rong)補償和(he)進相(xiang)器補償的原理圖分別如(ru)下:






圖(tu)中,將(jiang)電(dian)(dian)(dian)(dian)(dian)(dian)機(ji)進行(xing)了等(deng)效(xiao)簡化,R1、X1為(wei)(wei)(wei)電(dian)(dian)(dian)(dian)(dian)(dian)機(ji)定子等(deng)效(xiao)電(dian)(dian)(dian)(dian)(dian)(dian)路(lu)的電(dian)(dian)(dian)(dian)(dian)(dian)阻和電(dian)(dian)(dian)(dian)(dian)(dian)感,R2、X2為(wei)(wei)(wei)電(dian)(dian)(dian)(dian)(dian)(dian)機(ji)轉子等(deng)效(xiao)電(dian)(dian)(dian)(dian)(dian)(dian)路(lu)的電(dian)(dian)(dian)(dian)(dian)(dian)阻和電(dian)(dian)(dian)(dian)(dian)(dian)感,C為(wei)(wei)(wei)就(jiu)地補償(chang)的電(dian)(dian)(dian)(dian)(dian)(dian)容,Uf為(wei)(wei)(wei)進相(xiang)器的等(deng)效(xiao)電(dian)(dian)(dian)(dian)(dian)(dian)路(lu),M為(wei)(wei)(wei)電(dian)(dian)(dian)(dian)(dian)(dian)機(ji)的接(jie)線點。

從圖可以看出,靜止(zhi)式進(jin)相器(qi)和(he)電(dian)(dian)容(rong)補償(chang)(chang)對電(dian)(dian)機的作用點不同,電(dian)(dian)容(rong)是在(zai)電(dian)(dian)機的前(qian)端定子側進(jin)行(xing)補償(chang)(chang),其(qi)補償(chang)(chang)范(fan)圍是在(zai)補償(chang)(chang)點的前(qian)端;靜止(zhi)式進(jin)相器(qi)串聯(lian)在(zai)電(dian)(dian)機的后端,其(qi)補償(chang)(chang)范(fan)圍擴(kuo)大到了(le)電(dian)(dian)機。

五性(xing)能特點

1、可使電(dian)機的(de)功(gong)率(lv)因數提高到0.95以(yi)上,無功(gong)功(gong)率(lv)降(jiang)低60%以(yi)上。

2、降(jiang)低定子電(dian)流(liu)10%-20%。

3、降低線損、銅損20%-30%。

4、電機(ji)溫(wen)升降低(di)5%。

5、過載能力和效率大大提高(gao),電機使用壽命(ming)延(yan)長。

6、具(ju)有故障(zhang)自動保護(hu)功(gong)能,保障(zhang)設備長期(qi)安全運行(xing)。

7、操(cao)作簡單,安裝調(diao)試(shi)和(he)維修保養均不(bu)影響(xiang)正常生(sheng)產,半年內可(ke)收回成本。

六使(shi)用條(tiao)件

1、安裝地點環(huan)境溫(wen)度≤40℃

2、安(an)裝地點相對濕度(du)≤90%

3、 安裝地點(dian)無火(huo)災、爆炸危(wei)險品,無化學腐(fu)蝕及劇烈振動。

4、海拔高度≤1500M。

5、進相(xiang)器(qi)柜(ju)體(ti)上方0.5米(mi)內應通風;如無(wu)地溝(gou),須將進相(xiang)器(qi)柜(ju)體(ti)架空0.1米(mi)。

注:TP系列靜止式(shi)進(jin)相器應滿足上方要求的(de)使用條件(jian),襄陽拓邦電氣還(huan)可提供適用(yong)于高原(yuan)地(di)區(qu)(海拔超過(guo)1500米)的靜止式進相器(但用戶須事先特別申請)。

七技(ji)術參數


相 器 型 號

配 電 機 參 數

額定轉子電流(A

額定功率(KW

TP-400

400

95-800

TP-500

400-500

245-1000

TP-600

500-600

315-1250

TP-800

600-800

630-1600

TP-1000

800-1000

1000-2000

TP-1200

1000-1200

1600-2500

TP-1500

1200-1500

2000以上




八安裝(zhuang)尺(chi)寸

1、外型尺(chi)寸圖(tu)






2、安裝基礎圖







3、規格尺寸表



型號

外形尺寸(MM)

安裝尺寸(MM)

(W)

(D)

(H)

(E)

(F)

螺(luo)孔(kong)

TP400-600

1000

760

2000

780

620

14

TP800-1000

1100

800

2000

880

650

14

TP1200-1500

1200

900

2200

980

750

16



注:隨著產(chan)品不斷更新換代,外形及安裝尺寸會有所變(bian)化,請(qing)以具體的產(chan)品為準(zhun)。

九安(an)裝調試(shi)

(一(yi))安裝

1、將進(jin)相器搬到安裝位置,注意進(jin)相器柜(ju)體底部應與(yu)地溝相通或架空(kong),首(shou)先是打開柜(ju)子的前后門,從上到下(xia),逐(zhu)一地擰緊螺(luo)絲,防止(zhi)在運(yun)輸(shu)過程中螺(luo)絲松動造成進(jin)相器不能正常工作。

2、準備(bei)好(hao)連接【主電(dian)(dian)機(ji)(ji)轉(zhuan)子至(zhi)進相器接觸器KM13的三根電(dian)(dian)纜(lan)】、【進相器接觸器KM11至(zhi)主電(dian)(dian)機(ji)(ji)起動柜(ju)的三根電(dian)(dian)纜(lan)】,其(qi)線徑應能承載(zai)主電(dian)(dian)機(ji)(ji)轉(zhuan)子額定電(dian)(dian)流,比好(hao)長度并壓好(hao)接頭。

3、進相(xiang)器(qi)上(shang)的(de)電(dian)(dian)流(liu)(liu)表、功率(lv)因數表是直(zhi)接從電(dian)(dian)機(ji)定(ding)子回路上(shang)的(de)電(dian)(dian)流(liu)(liu)互(hu)感(gan)器(qi)、電(dian)(dian)壓(ya)互(hu)感(gan)器(qi)取信(xin)號,要求(qiu)(qiu)所(suo)用電(dian)(dian)流(liu)(liu)互(hu)感(gan)器(qi)副邊(bian)的(de)額定(ding)電(dian)(dian)流(liu)(liu)為5A、電(dian)(dian)壓(ya)互(hu)感(gan)器(qi)副邊(bian)的(de)額定(ding)電(dian)(dian)壓(ya)為100V,若用戶(hu)現用的(de)不滿足(zu)該要求(qiu)(qiu),則(ze)須另(ling)行準(zhun)備符合上(shang)述(shu)要求(qiu)(qiu)的(de)互(hu)感(gan)器(qi)。(注:電(dian)(dian)壓(ya)互(hu)感(gan)器(qi)僅適(shi)用于高壓(ya)電(dian)(dian)機(ji),對低壓(ya)電(dian)(dian)機(ji),進相(xiang)器(qi)電(dian)(dian)壓(ya)信(xin)號直(zhi)接從定(ding)子回路取)

4、新電(dian)機須帶上90%以(yi)上負載并正常運轉(zhuan)后才可(ke)調試進(jin)(jin)相器(qi),用戶在通知我(wo)方調試前,應調試好電(dian)機、減速機、磨機等其它(ta)設備,使其帶上負載正常運轉(zhuan),以(yi)免延誤(wu)進(jin)(jin)相器(qi)調試時間(jian)。

5、各(ge)聯鎖線意義(yi)如下:

(225、227)取自(zi)電機起動柜星點短接(jie)接(jie)觸器的輔(fu)助常(chang)開點,只有在電機起動完畢后,進(jin)相器才可以進(jin)相。

(355、357)當開關(guan)柜主開關(guan)是接觸器時(shi)與分閘(zha)(zha)按鈕并聯(lian);是斷(duan)路器時(shi)與分閘(zha)(zha)按鈕串聯(lian), 進相(xiang)狀態下(xia)主電機不(bu)能停機,只有先(xian)退相(xiang)才(cai)能停主機。

(359、361)串入開關柜合閘回路(lu)。當KM11吸合時,可以起(qi)動電機。

(363、369)從起動(dong)柜(ju)控制電(dian)源引單相(xiang)380V,使KM11與起動(dong)柜(ju)控制回路同(tong)時得電(dian)。

(30、32)串入主電機電流(liu)計量回路(lu);(40、42)并入主電機電壓(ya)(ya)計量回路(lu)。(取(qu)A相(xiang)(xiang)電流(liu)則取(qu)B,C相(xiang)(xiang)電壓(ya)(ya),如此類推(tui),電流(liu)和電壓(ya)(ya)不得取(qu)同相(xiang)(xiang))。

(A、B、C、N)接三相四線(xian)電源,導線(xian)橫截面(mian)積:TP600以(yi)下用4mm2;TP1000以(yi)下用6mm2;TP1500以(yi)下用10mm2。

6、控制(zhi)器所有指(zhi)示燈的含(han)義(yi)說明如(ru)下:

(1)主板(中間一塊)的指(zhi)示燈(從上往下數)

●L1、L2、L3:電機(ji)轉子三相(xiang)電流信號(hao)指(zhi)示(電機(ji)運轉時(shi)為循環(huan)顯示狀態(tai)(tai);自檢試驗時(shi)為隨機(ji)狀態(tai)(tai):或亮、或滅(mie))

●L4:+5V電(dian)源指示(保持(chi)亮的狀態)

●L5:熱故障指示(有熱故障時L5滅)

●L6:缺相及自動故障(zhang)保護指示(有缺相故障(zhang)及其它故障(zhang)時L6燈(deng)滅(mie))

●L7:+15V電源指示(保持亮的(de)狀態)

●L8:-15V電源指示(shi)(保(bao)持亮的狀態(tai))

(2)驅(qu)動板(兩(liang)邊(bian)兩(liang)塊)

●分別代表(biao)12個(ge)可控制硅的觸(chu)發信號(指示燈均亮,并有規律(lv)的閃爍)

(二(er))試(shi)驗(yan)

1、檢查主電纜(lan)、聯鎖(suo)線、儀表線連接(jie)是否正確。

2、檢(jian)查各器件螺(luo)絲是(shi)否緊固。

3、用萬用表測量可(ke)控硅極(ji)間電阻:

●觸發極G與陰極K間電(dian)阻(zu)為幾十(shi)歐姆;

●觸發極G與陽(yang)極A間電阻大(da)于(yu)幾十千(qian)歐(ou);

●陰極(ji)K與(yu)陽極(ji)A間電(dian)阻大于幾十(shi)千(qian)歐(ou);

●陰極K與(yu)陽(yang)極A用(yong)(yong)萬用(yong)(yong)表200K檔(dang)測量,阻值應從小變化到無限(xian)大。

4、合上(shang)(shang)起動柜(ju)電(dian)源,進相器(qi)背(bei)面的接(jie)觸器(qi)KM11應吸(xi)合,短接(jie)225、227;合上(shang)(shang)進相器(qi)電(dian)源,電(dian)源指示燈(deng)亮(liang);控制器(qi)應有電(dian),控制器(qi)上(shang)(shang)指示燈(deng)亮(liang)。

5、控制(zhi)器(qi)上撥碼(ma)開(kai)關(guan)打在ON(上方)位置,中間(jian)主板(ban)L1、L2、L3循環亮或(huo)滅,L4~L8全亮;兩(liang)邊兩(liang)塊驅(qu)動(dong)板(ban)指示(shi)燈閃爍。

6、按綠(lv)色進相按鈕(niu),進相器前面(mian)的接(jie)觸(chu)器KM13吸合,延時后,背面(mian)的接(jie)觸(chu)器KM11斷開,綠(lv)色進相指(zhi)示燈(deng)亮,風(feng)機運轉,風(feng)應向上吹,主(zhu)變壓器副邊電流(liu)不超(chao)過(guo)30A,并(bing)且沒(mei)有大幅度變化。

7、按(an)紅色退相按(an)鈕(niu),進(jin)相器(qi)后(hou)面(mian)(mian)的接觸器(qi)KM11吸合,延時后(hou),前面(mian)(mian)的接觸器(qi)KM13斷(duan)開(kai),綠色進(jin)相指(zhi)示燈滅,紅色電源指(zhi)示燈亮(liang),進(jin)相器(qi)即退出進(jin)相狀(zhuang)態(tai)。

8、通電試驗結束,請務必斷(duan)開225、227。

(三)調試(shi)

1、運行前:控制器主板上撥碼開關應打在OFF(下方)位置。

2、起(qi)動主電(dian)(dian)機:打開(kai)進(jin)相器前柜門,合上空氣開(kai)關,進(jin)相器電(dian)(dian)源接通(tong),面板(ban)上的紅色電(dian)(dian)源指示(shi)燈(deng)亮,關閉柜門,等待主機起(qi)動。

3、進(jin)相:(1)電機正常(chang)運(yun)轉后(hou),按綠色進(jin)相按鈕(niu),進(jin)相器前面的接(jie)觸器KM13吸合,延時后(hou),背面的接(jie)觸器KM11斷開,綠色進(jin)相指示燈亮(liang),風機運(yun)轉,定(ding)子(zi)電流(liu)應(ying)下降(jiang),功率因數應(ying)上(shang)(shang)升。如果定(ding)子(zi)電流(liu)不(bu)下降(jiang)反而上(shang)(shang)升,調整同步變壓器上(shang)(shang)6V、6V0兩線的位置(zhi),再(zai)進(jin)相。

(2)測(ce)量主變壓器(qi)原、副(fu)邊電流,應無大幅度(du)擺動。

(3)電(dian)(dian)機定子電(dian)(dian)流應平穩,無大幅(fu)度擺動。

(4)六個電抗器上端銅排的電流擺動(dong)幅(fu)度應(ying)一致。

4、退(tui)相(xiang):按紅色退(tui)相(xiang)按鈕,進(jin)(jin)相(xiang)器后面的接觸(chu)器KM11吸(xi)合(he),延(yan)時(shi)后,前面的接觸(chu)器KM13斷(duan)開,綠色進(jin)(jin)相(xiang)指示燈滅,紅色電源指示燈亮,進(jin)(jin)相(xiang)器即(ji)退(tui)出進(jin)(jin)相(xiang)狀態(tai)。

5、停車(che):進相器退相后(hou),按(an)下(xia)主機停車(che)按(an)鈕,電機即停車(che)。

(四)測量和觀(guan)察(cha)

1、測量可控硅、銅排、交流接觸器、電抗器、主變壓器、控制(zhi)板溫度。

2、測量可控硅觸(chu)發(fa)電(dian)(dian)壓;主變壓器一次、二次電(dian)(dian)流(liu)(liu);電(dian)(dian)抗器輸入電(dian)(dian)流(liu)(liu)。

3、觀察風機(ji)運行情況。

4、觀察(cha)整(zheng)體運行(xing)情況(kuang),有無異常響聲或銅排有無大的抖動現(xian)象等(deng)。

十(shi)使用維護(hu)

為確保TP系列靜止式進相器長期安全、可靠地運行,請操作人(ren)員特(te)別注意以下事項:

1、嚴禁在(zai)進相器運行期(qi)間,切斷進相器外部電源。

2、定期檢查冷(leng)卻風機運轉狀況(kuang),冷(leng)卻風機停轉使(shi)可控(kong)硅散(san)熱能力下降,可能燒壞可控(kong)硅。

3、定期檢測(ce)主變(bian)壓器原(yuan)、副邊(bian)運(yun)行(xing)電流。

4、定期檢測(ce)可(ke)控硅、聯接銅排、交流接觸(chu)器(qi)(qi)、電抗器(qi)(qi)、主變壓器(qi)(qi)、控制板的溫度(du)。

5、定期檢(jian)修主(zhu)回路(lu)接(jie)觸器的觸頭。真(zhen)空接(jie)觸器定期檢(jian)測絕緣電(dian)阻,用(yong)5KV或2.5KV搖表檢(jian)查,當(dang)開關管(guan)絕緣電(dian)阻小(xiao)于100兆(zhao)歐時(shi),應(ying)加強監視,小(xiao)于20兆(zhao)歐時(shi)應(ying)立即更(geng)換新管(guan),以延長接(jie)觸器的使用(yong)壽命,保障進(jin)相(xiang)器及(ji)電(dian)機(ji)安全運行。

6、當(dang)進相(xiang)器停用(yong)一段時間(jian)又(you)重(zhong)新啟用(yong)時, 次進相(xiang)前應觀察柜(ju)內控制單元上各(ge)指(zhi)示(shi)燈是否正(zheng)常。電(dian)機(ji)起動并正(zheng)常運轉后(hou),各(ge)指(zhi)示(shi)燈顯(xian)示(shi)如下(xia):

·主(zhu)板(中間一塊):除L1,L2,L3周期性循環顯示外(注意:此指電機(ji)(ji)在運轉時的(de)狀態(tai),若電機(ji)(ji)未轉,該三燈(deng)為隨機(ji)(ji)狀態(tai)),其它各(ge)燈(deng)均亮。

·驅動扳(ban)(兩邊的兩塊):其上面各指(zhi)示燈均(jun)亮并有輕微(wei)閃爍。

7、當電機(ji)定子電流出現異常大幅擺動時,應立即退(tui)相(xiang),查出原因并(bing)檢修后投入使用(yong)。

8、定期打掃柜內衛生。

十一故(gu)障(zhang)處理



主電機不能起動

端子363、369無380V 電源

檢查(cha)起(qi)動柜控制電源

 

接觸器KM11不吸合

檢查KM11線包及其控制回路

 

接觸器KM11吸合,但其輔助觸點未閉合

檢修其輔助(zhu)觸點

 

端子359、361串入合閘回路的線未接通

檢(jian)查該回路

不(bu)能投入進相

空氣開關QF1、QF2、QF3沒合上

合上空氣開關

 

按鈕STP、ST接觸不良

 

 

中間繼電器KA11觸點接觸不良

 

 

主電機起動柜內星點接觸器常開輔助觸點不能閉合(225、227未接通)

檢(jian)修該接觸器輔(fu)助觸點及(ji)連線

 

KM13不(bu)能吸(xi)合(he)

檢查KM13線包及其控制回路

 

固態繼電器FV損壞或者不導通

控制器主控制板L6燈滅

檢查主控板7腳對11、12、13腳有無+、-3伏左右電壓,否則更換電流傳感器

 

 

檢查固態繼電器FV

FV的3、4腳有直流15V電壓(ya),而323、325不通,須更換該繼電器

進相后主電機(ji)停機(ji)

接入開關柜的KM11、KM13的輔助觸點359、361接觸不好

維修(xiu)該觸點

 

進相(xiang)器投入進相(xiang)瞬(shun)間外部(bu)空氣(qi)開關(guan)跳閘

更換大規格的空氣(qi)開關

進(jin)相后(hou)無效果

接入主控板的電流傳感器信號線錯誤

電流傳感器從左到右TA1、TA2、TA3的信號線應分別對應與主控板的13、12、11腳

 

主控板的撥碼開(kai)關(guan)在自檢位(wei)

撥碼開關撥至工作位

 

KM13吸合后KM11未釋放(時間繼電器KT11壞(huai))

更換KT11時間繼電器

 

KM15沒有吸合

KM11的輔助觸點301、305接觸不(bu)良

維修該(gai)觸點

 

 

KM15線圈故障

更換KM15線圈

 

KM15主觸(chu)點接觸(chu)不良

更換KM15

 

主變壓器原邊開路

更換主變壓器

進相(xiang)后主(zhu)電(dian)機電(dian)流不減反增

同步電源相(xiang)序錯誤

調換進相器內小變壓器TC上輸出6V、6V0電壓的兩線位置

 

電機轉速下降(缺相),自動退相

KM13主觸(chu)點接觸(chu)不良

維修該(gai)觸點

 

 

電機轉子(zi)線松動,進相(xiang)時(shi)的電流沖擊導(dao)致缺相(xiang)

檢(jian)查電(dian)機轉子線

進相后(hou)主電機電流擺(bai)動大(da)

可控硅(gui)擊穿

測量(liang)可控(kong)硅極間(jian)電阻(詳(xiang)細方(fang)法見調(diao)試部分)

 

觸發板損壞

測量可控硅控制極與陰極之間應有0.2V以上的直流電壓信號,否則應檢查觸發板

 

主板的撥碼開(kai)關在自檢位

撥碼開關(guan)撥至工作位

 

電機轉子線(xian)松動

檢(jian)查電機(ji)轉子線

 

KM13采用節能型線圈時,線圈故障導致KM13進行瞬間來回釋放、吸合,導致主回路接觸不良

維修或更換KM13線圈





注意(yi):進相器檢修不得在進相(xiang)狀態下進行,發現問題應立即退相(xiang)。

十二控制板檢修



現象

原因

對策

L1L2L3不循環閃爍,L6滅,其它各燈正常

轉子缺(que)相

檢查接觸器KM2主觸頭是否損壞,若損壞,則維修觸頭或更換接觸器

電流傳感器器損壞

檢查電流傳感器是否有±2V以上的輸出信號,否則更換傳感器

主控(kong)板元(yuan)器(qi)件損壞

依次更換IC210IC211

L1L2L3不周期性閃爍,其它各燈正常

主(zhu)控板元器(qi)件(jian)損壞(huai)

依次更換IC210IC211IC205IC207

L6滅,其它各燈正常

主控板元器件損壞(huai)

依次更換IC207IC209

L5滅,其它各燈正常

散熱器溫度檢(jian)測回路故障

檢查溫度(du)開關及其連線(xian)

L4L7L8全部或部分滅

電源故障

1、檢查變壓器及控制板是否有±18V電源

2、更換相應的780578157915

F1-L1L6 F2-L1L6部分指示燈亮,主板各燈正常

觸(chu)發板(ban)元器件損壞

1、有一片ULN2004損壞,更換之

2、脈沖變壓器接觸不良,作相應處理

F1-L1L6 F2-L1L6指示燈全滅,主板各燈正常

觸(chu)發板元器件損壞

1、兩片ULN2004損壞,更換之

2、更換555芯片

觸發板無電源

1、檢查主板7815是否有虛焊

2、檢查觸發板19腳與主板6腳連接是否正常





十三注意事項(xiang)

1、進(jin)相(xiang)器檢修應(ying)(ying)在退(tui)相(xiang)狀態(tai)下進(jin)行(xing),發現問題(ti)應(ying)(ying)立即退(tui)相(xiang)。

2、嚴禁隨意(yi)帶(dai)電插拔控(kong)(kong)制板(ban),檢(jian)修控(kong)(kong)制板(ban)時(shi),一定要把空開QF3打下(xia)來。

3、更換可控硅(gui)時應注意(yi)陰、陽極的(de)方(fang)向,并(bing)壓緊(jin)散(san)熱器(壓力不(bu)要過大),裝上后擰緊(jin)所有螺絲(si),之后再檢測(ce)可控硅(gui)各極間的(de)電阻情況。若一(yi)只可控硅(gui)擊穿在(zai)柜體上直接檢測(ce),同一(yi)相的(de)四個可控硅(gui)均顯示擊穿,此時應把(ba)該組(zu)可控硅(gui)間的(de)聯接銅排拆掉(diao)再測(ce) 。

十四訂貨須知(zhi)

1、提供電機型號、額定(ding)功率(lv)、定(ding)子電壓、定(ding)子電流(liu)、轉子電壓、轉子電流(liu)、額定(ding)功率(lv)因數(shu)。

2、提供電機拖(tuo)動負載(zai)的特(te)征及負載(zai)率。

預(yu)知(zhi)TP系列無環流靜止式進相器的更多信(xin)息,請撥打襄陽拓邦電氣官網電話: 鄭經理17771133316或咨詢(xun)網站客(ke)服!!

在線留言

LEAVE A MESSAGE