欧美最猛性XXXXX69交_亚洲精品无码永久电影在线_欧美黑人粗大xxxxbbbb_中文字幕日韩精品有码视频

衡陽產品中心
衡陽產品中心

衡陽產品中心

product

衡陽TP系列靜止式進相器

一(yi)概述TP系列無環(huan)流靜止式(shi)進相(xiang)器是襄陽拓邦電氣自選研制開發(fa)的新一(yi)代(dai)高(gao)新技術產品,是一(yi)種專為大中(zhong)型繞線式(shi)異(yi)……

相關內容
在線留言
詳情內容
content details

TP系列無環流靜止式進相器是(shi)(shi)襄陽拓邦電(dian)(dian)(dian)(dian)(dian)(dian)(dian)(dian)氣自選研(yan)制(zhi)開發(fa)的(de)(de)新(xin)一(yi)代高(gao)新(xin)技術產(chan)品(pin),是(shi)(shi)一(yi)種專為大中型繞線式異步電(dian)(dian)(dian)(dian)(dian)(dian)(dian)(dian)動機(ji)設計制(zhi)作的(de)(de)就地(di)無功(gong)(gong)功(gong)(gong)率(lv)(lv)補償裝置。它串(chuan)接于電(dian)(dian)(dian)(dian)(dian)(dian)(dian)(dian)機(ji)轉子(zi)(zi)回(hui)路,改(gai)變轉子(zi)(zi)電(dian)(dian)(dian)(dian)(dian)(dian)(dian)(dian)流與轉子(zi)(zi)電(dian)(dian)(dian)(dian)(dian)(dian)(dian)(dian)壓的(de)(de)相位關系,通過磁場進而(er)改(gai)變電(dian)(dian)(dian)(dian)(dian)(dian)(dian)(dian)機(ji)定子(zi)(zi)電(dian)(dian)(dian)(dian)(dian)(dian)(dian)(dian)流與電(dian)(dian)(dian)(dian)(dian)(dian)(dian)(dian)壓的(de)(de)相位關系,達到提(ti)高(gao)電(dian)(dian)(dian)(dian)(dian)(dian)(dian)(dian)機(ji)自身(shen)功(gong)(gong)率(lv)(lv)因(yin)數(shu)、降(jiang)低(di)電(dian)(dian)(dian)(dian)(dian)(dian)(dian)(dian)機(ji)定子(zi)(zi)電(dian)(dian)(dian)(dian)(dian)(dian)(dian)(dian)流和(he)溫(wen)升(sheng)的(de)(de)目的(de)(de)。這種方式從根本(ben)上改(gai)善(shan)了電(dian)(dian)(dian)(dian)(dian)(dian)(dian)(dian)機(ji)的(de)(de)運行狀況(kuang),顯著降(jiang)低(di)電(dian)(dian)(dian)(dian)(dian)(dian)(dian)(dian)機(ji)及(ji)電(dian)(dian)(dian)(dian)(dian)(dian)(dian)(dian)網的(de)(de)無功(gong)(gong)損耗,對節能降(jiang)耗、降(jiang)低(di)單位產(chan)品(pin)成本(ben),提(ti)高(gao)企業的(de)(de)經(jing)濟效益(yi)具有重(zhong)要(yao)的(de)(de)意義。


TP系(xi)列無環流(liu)靜止式進(jin)相(xiang)器對(dui)無功(gong)(gong)功(gong)(gong)率的補(bu)償(chang)與電(dian)機定(ding)子側并(bing)聯電(dian)容器的補(bu)償(chang)有著本質的區別。電(dian)容補(bu)償(chang)只(zhi)是(shi)在電(dian)機之外的電(dian)網上(shang)對(dui)無功(gong)(gong)進(jin)行補(bu)償(chang),減少(shao)電(dian)網的無功(gong)(gong)輸入,電(dian)網的功(gong)(gong)率因數得到提高,但是(shi)電(dian)機的無功(gong)(gong)消耗(hao)并(bing)沒(mei)有減少(shao),無法改善電(dian)機本身的運行狀(zhuang)況;而TP系列靜止式進相器是串接在電(dian)(dian)機(ji)(ji)(ji)轉子回路中,不僅可顯著提(ti)高功率(lv)因數,使電(dian)(dian)機(ji)(ji)(ji)定子電(dian)(dian)流(liu)大幅(fu)度降低,而且電(dian)(dian)機(ji)(ji)(ji)溫升明顯降低,電(dian)(dian)機(ji)(ji)(ji)的效率(lv)和(he)過載能力顯著提(ti)高。

TP系列(lie)(lie)靜(jing)止(zhi)式(shi)(shi)(shi)進相(xiang)(xiang)器(qi)(qi)與(yu)自(zi)激(ji)(ji)(旋轉(zhuan))式(shi)(shi)(shi)進相(xiang)(xiang)機(ji)(ji)(ji)也不同。TP系列(lie)(lie)靜(jing)止(zhi)式(shi)(shi)(shi)進相(xiang)(xiang)器(qi)(qi)采用(yong)了 的(de)(de)交(jiao)-交(jiao)變(bian)頻(pin)技(ji)(ji)術和微機(ji)(ji)(ji)、可控(kong)(kong)硅控(kong)(kong)制技(ji)(ji)術,可自(zi)動(dong)(dong)跟蹤電機(ji)(ji)(ji)運行狀(zhuang)態的(de)(de)變(bian)化(hua)并(bing)自(zi)動(dong)(dong)調整相(xiang)(xiang)關參數以達到佳的(de)(de)補(bu)償效果,這是自(zi)激(ji)(ji)式(shi)(shi)(shi)進相(xiang)(xiang)機(ji)(ji)(ji)無法做到的(de)(de)。而(er)且,TP系列(lie)(lie)靜(jing)止(zhi)式(shi)(shi)(shi)進相(xiang)(xiang)器(qi)(qi)從根本(ben)上克服了自(zi)激(ji)(ji)式(shi)(shi)(shi)進相(xiang)(xiang)機(ji)(ji)(ji)“整流(liu)子”結構特別怕塵(chen)埃(ai)、壽命短、維修(xiu)頻(pin)繁的(de)(de)缺點;具(ju)有參數調節(jie)容易、主回路無轉(zhuan)動(dong)(dong)部件(jian)、不怕灰(hui)塵(chen)、可靠性高、使用(yong)壽命長、維護方便,是理想的(de)(de)取(qu)代(dai)自(zi)激(ji)(ji)式(shi)(shi)(shi)進相(xiang)(xiang)機(ji)(ji)(ji)的(de)(de)新型高科技(ji)(ji)產品。

TP系列靜止(zhi)式(shi)進相器(qi)可廣(guang)泛用于水泥(ni)、化工(gong)、礦(kuang)山(shan)、冶金、鋼鐵、造紙、制藥等(deng)行(xing)業的大(da)中型(xing)高低(di)壓繞(rao)線式(shi)異步電機。


二(er)型(xing)號(hao)命(ming)名

TP系列靜止式進相器型號命名方法(fa)如下:





型(xing)號(hao):TP-800,表示(shi)適用于(yu)額定轉子電(dian)流(liu)不超過800A的(de)電(dian)機的(de)靜止式進相器。


三工作(zuo)原理

當電(dian)機(ji)(ji)運行進(jin)(jin)相(xiang)時(shi),進(jin)(jin)相(xiang)器(qi)通過轉(zhuan)(zhuan)子(zi)(zi)(zi)電(dian)流傳(chuan)感器(qi)采集到(dao)的(de)(de)轉(zhuan)(zhuan)子(zi)(zi)(zi)電(dian)流信(xin)號及工(gong)頻(pin)電(dian)壓(ya)提供的(de)(de)同步信(xin)號經微處理器(qi)CPU進(jin)(jin)行數(shu)據(ju)和相(xiang)位(wei)(wei)處理,控制可(ke)控硅的(de)(de)觸(chu)發(fa)信(xin)號,調整(zheng)由12只晶閘(zha)管(guan)組(zu)成的(de)(de)交(jiao)—交(jiao)變(bian)(bian)頻(pin)裝(zhuang)置,將降壓(ya)后的(de)(de)工(gong)頻(pin)電(dian)源變(bian)(bian)為(wei)和轉(zhuan)(zhuan)子(zi)(zi)(zi)電(dian)流同頻(pin)率(lv),相(xiang)位(wei)(wei)滯后90°的(de)(de)附加(jia)電(dian)勢加(jia)在電(dian)機(ji)(ji)轉(zhuan)(zhuan)子(zi)(zi)(zi)回路中(zhong)。轉(zhuan)(zhuan)子(zi)(zi)(zi)的(de)(de)電(dian)流和電(dian)壓(ya)相(xiang)位(wei)(wei)因(yin)此改變(bian)(bian),通過磁場進(jin)(jin)而改變(bian)(bian)電(dian)機(ji)(ji)定子(zi)(zi)(zi)電(dian)流與(yu)定子(zi)(zi)(zi)電(dian)壓(ya)的(de)(de)相(xiang)位(wei)(wei)角,使電(dian)機(ji)(ji)的(de)(de)功率(lv)因(yin)數(shu)提高(gao),得到(dao)補(bu)償。

當電機在(zai)某一(yi)負(fu)載下運行時,其轉子電流為I2e、定子電流為I1e, 向量圖如下所示。







從(cong)(cong)電機學我(wo)們知(zhi)道,激磁電流(liu)(liu)Im由關系式(shi)Im=I1e-I2e,從(cong)(cong)向(xiang)量(liang)(liang)圖(tu)可得出(chu)Im。當進相(xiang)器(qi)的(de)(de)電勢(shi)疊加在轉子回路(lu)后,轉子電流(liu)(liu)的(de)(de)相(xiang)位變(bian)為(wei)圖(tu)中(zhong)的(de)(de)I2。由于負載不(bu)變(bian),激磁電流(liu)(liu)Im不(bu)變(bian)。此時的(de)(de)定(ding)子電流(liu)(liu)I1由關系式(shi)I1=Im+I2從(cong)(cong)向(xiang)量(liang)(liang)圖(tu)可得出(chu)I1,如圖(tu)所(suo)示(shi)。從(cong)(cong)圖(tu)中(zhong)可以看出(chu)I1的(de)(de)功率因(yin)數角和(he)幅值都比I1e小,說明電機的(de)(de)功率因(yin)數有所(suo)提高,定(ding)子電流(liu)(liu)有所(suo)下降。

進相(xiang)器就是這樣改變轉(zhuan)子(zi)(zi)電(dian)流(liu)與(yu)轉(zhuan)子(zi)(zi)電(dian)壓(ya)(ya)的相(xiang)位(wei)關系(xi),通過磁場進而(er)改變電(dian)機(ji)定(ding)子(zi)(zi)電(dian)流(liu)與(yu)定(ding)子(zi)(zi)電(dian)壓(ya)(ya)的相(xiang)位(wei)關系(xi),減小(xiao)功率(lv)因(yin)數角,終使電(dian)機(ji)本身的功率(lv)因(yin)數得以(yi)提高,定(ding)子(zi)(zi)電(dian)流(liu)得以(yi)下(xia)降,達到(dao)對電(dian)機(ji)補償的目的。

當負(fu)載發生改變時(shi),微處理器實時(shi)檢測電(dian)機參數的(de)變化,并(bing)根據(ju)負(fu)載的(de)變化,動態調整附加(jia)在轉子上的(de)電(dian)勢幅值,以使電(dian)機的(de)功率因數始終保持在期望值上。

四原理(li)框圖






電容式補償(chang)的矢量分析:








電容補償(chang)和(he)進相器補償(chang)的(de)原(yuan)理圖分(fen)別(bie)如下:






圖中,將電(dian)(dian)(dian)機進行了等(deng)(deng)效簡化,R1、X1為電(dian)(dian)(dian)機定子(zi)等(deng)(deng)效電(dian)(dian)(dian)路(lu)的電(dian)(dian)(dian)阻(zu)和(he)電(dian)(dian)(dian)感(gan),R2、X2為電(dian)(dian)(dian)機轉子(zi)等(deng)(deng)效電(dian)(dian)(dian)路(lu)的電(dian)(dian)(dian)阻(zu)和(he)電(dian)(dian)(dian)感(gan),C為就地(di)補償(chang)的電(dian)(dian)(dian)容,Uf為進相(xiang)器的等(deng)(deng)效電(dian)(dian)(dian)路(lu),M為電(dian)(dian)(dian)機的接線點(dian)。

從(cong)圖(tu)可(ke)以看(kan)出(chu),靜(jing)止(zhi)式(shi)進(jin)相(xiang)器和電容補(bu)(bu)償對(dui)電機(ji)(ji)的(de)作用(yong)點不(bu)同,電容是(shi)在(zai)電機(ji)(ji)的(de)前端定子側進(jin)行補(bu)(bu)償,其補(bu)(bu)償范圍是(shi)在(zai)補(bu)(bu)償點的(de)前端;靜(jing)止(zhi)式(shi)進(jin)相(xiang)器串聯(lian)在(zai)電機(ji)(ji)的(de)后端,其補(bu)(bu)償范圍擴大到了電機(ji)(ji)。

五性能特點

1、可使電(dian)機的功率(lv)因數(shu)提高到0.95以(yi)上,無功功率(lv)降低60%以(yi)上。

2、降低定子電(dian)流10%-20%。

3、降低線損(sun)、銅損(sun)20%-30%。

4、電機(ji)溫升降(jiang)低5%。

5、過載(zai)能力和效(xiao)率大大提高,電機使(shi)用壽命(ming)延長。

6、具(ju)有故障自動保護功(gong)能,保障設備長期安全運行。

7、操(cao)作(zuo)簡單,安裝調(diao)試和維修保養均不影響正常生產,半(ban)年內可收回(hui)成本。

六使用(yong)條件(jian)

1、安裝地點環境溫度(du)≤40℃

2、安裝地點相對濕度≤90%

3、 安裝地點無火災、爆炸危險品,無化學腐(fu)蝕及(ji)劇烈振(zhen)動。

4、海拔高度≤1500M。

5、進相器柜(ju)體上(shang)方0.5米內應通風;如無地溝,須將進相器柜(ju)體架空0.1米。

注(zhu):TP系(xi)列(lie)靜止式進(jin)相器應滿足上方(fang)要(yao)求的使用(yong)條件,襄陽拓邦電氣還可提供適用(yong)于高原地區(海拔超過1500米)的靜止式進相器(但(dan)用戶(hu)須事先特(te)別(bie)申(shen)請(qing))。

七(qi)技(ji)術參數


相 器 型 號

配 電 機 參 數

額定轉子電流(A

額定功率(KW

TP-400

400

95-800

TP-500

400-500

245-1000

TP-600

500-600

315-1250

TP-800

600-800

630-1600

TP-1000

800-1000

1000-2000

TP-1200

1000-1200

1600-2500

TP-1500

1200-1500

2000以上




八安裝尺寸

1、外型尺寸圖






2、安裝(zhuang)基礎圖







3、規格尺寸表



型號

外形尺寸(MM)

安裝尺寸(MM)

(W)

(D)

(H)

(E)

(F)

螺孔

TP400-600

1000

760

2000

780

620

14

TP800-1000

1100

800

2000

880

650

14

TP1200-1500

1200

900

2200

980

750

16



注:隨著產品(pin)不斷更新換代(dai),外形及安裝尺寸會有所變(bian)化,請以具(ju)體的(de)產品(pin)為準(zhun)。

九安(an)裝調試

(一)安裝

1、將進相器(qi)搬(ban)到安裝位置,注意進相器(qi)柜(ju)(ju)體底部應與地溝(gou)相通或(huo)架空(kong),首先是打(da)開(kai)柜(ju)(ju)子的(de)前后門,從(cong)上(shang)到下,逐一地擰緊螺(luo)絲(si),防止在運輸過程中螺(luo)絲(si)松動造成(cheng)進相器(qi)不能(neng)正(zheng)常工作。

2、準備好(hao)連接【主電(dian)機(ji)(ji)轉子至進相器(qi)接觸(chu)器(qi)KM13的三根電(dian)纜】、【進相器(qi)接觸(chu)器(qi)KM11至主電(dian)機(ji)(ji)起動柜的三根電(dian)纜】,其(qi)線徑應能承載(zai)主電(dian)機(ji)(ji)轉子額定電(dian)流,比好(hao)長(chang)度并壓好(hao)接頭。

3、進(jin)相器上(shang)的電(dian)(dian)流(liu)表(biao)、功率因數表(biao)是(shi)直(zhi)接從(cong)電(dian)(dian)機定子回(hui)(hui)路(lu)上(shang)的電(dian)(dian)流(liu)互(hu)感器、電(dian)(dian)壓互(hu)感器取信號,要(yao)求(qiu)所用電(dian)(dian)流(liu)互(hu)感器副(fu)邊的額(e)定電(dian)(dian)流(liu)為5A、電(dian)(dian)壓互(hu)感器副(fu)邊的額(e)定電(dian)(dian)壓為100V,若用戶現用的不滿足該要(yao)求(qiu),則須另行準備符合上(shang)述要(yao)求(qiu)的互(hu)感器。(注(zhu):電(dian)(dian)壓互(hu)感器僅適用于高壓電(dian)(dian)機,對低壓電(dian)(dian)機,進(jin)相器電(dian)(dian)壓信號直(zhi)接從(cong)定子回(hui)(hui)路(lu)取)

4、新(xin)電(dian)機須帶上90%以上負(fu)載并正(zheng)常運轉后(hou)才可調(diao)(diao)試進相器,用(yong)戶在通知我方(fang)調(diao)(diao)試前,應調(diao)(diao)試好電(dian)機、減速(su)機、磨機等其(qi)它設備,使其(qi)帶上負(fu)載正(zheng)常運轉,以免延誤(wu)進相器調(diao)(diao)試時(shi)間(jian)。

5、各聯(lian)鎖線意義如下:

(225、227)取自電(dian)機起動柜星點短接(jie)接(jie)觸(chu)器(qi)的輔助常開點,只有(you)在電(dian)機起動完畢后,進(jin)相器(qi)才可以進(jin)相。

(355、357)當(dang)開(kai)關柜主開(kai)關是接觸器時與(yu)分閘(zha)(zha)按鈕(niu)并聯;是斷路器時與(yu)分閘(zha)(zha)按鈕(niu)串聯, 進相狀(zhuang)態下主電機不能停機,只(zhi)有先(xian)退(tui)相才(cai)能停主機。

(359、361)串入開(kai)關柜合閘(zha)回路。當(dang)KM11吸合時,可以(yi)起動電(dian)機。

(363、369)從(cong)起動柜控制電源引單相380V,使KM11與(yu)起動柜控制回(hui)路同(tong)時得電。

(30、32)串入(ru)主電(dian)機電(dian)流(liu)計(ji)量回路(lu);(40、42)并(bing)入(ru)主電(dian)機電(dian)壓(ya)(ya)計(ji)量回路(lu)。(取A相電(dian)流(liu)則取B,C相電(dian)壓(ya)(ya),如此類(lei)推,電(dian)流(liu)和電(dian)壓(ya)(ya)不得取同相)。

(A、B、C、N)接三相四線電源(yuan),導線橫截面積:TP600以下(xia)用(yong)4mm2;TP1000以下(xia)用(yong)6mm2;TP1500以下(xia)用(yong)10mm2。

6、控制器所有指(zhi)示燈的含義說(shuo)明(ming)如下:

(1)主板(中(zhong)間一塊)的指示燈(從(cong)上(shang)往下數)

●L1、L2、L3:電機(ji)(ji)轉子三相電流(liu)信(xin)號(hao)指示(shi)(電機(ji)(ji)運轉時(shi)為循環顯(xian)示(shi)狀態;自檢(jian)試驗時(shi)為隨機(ji)(ji)狀態:或亮(liang)、或滅)

●L4:+5V電源(yuan)指示(保持亮的狀態)

●L5:熱故障指示(shi)(有熱故障時L5滅)

●L6:缺(que)相及自動故障(zhang)保護(hu)指示(有缺(que)相故障(zhang)及其它故障(zhang)時L6燈滅)

●L7:+15V電源指示(保持亮(liang)的狀態(tai))

●L8:-15V電(dian)源(yuan)指示(保持(chi)亮的狀(zhuang)態)

(2)驅動板(兩邊兩塊)

●分別(bie)代表(biao)12個可(ke)控(kong)制硅的觸發信號(指示燈均亮,并有規(gui)律的閃(shan)爍)

(二(er))試(shi)驗(yan)

1、檢查主電纜(lan)、聯鎖線(xian)、儀表線(xian)連接是(shi)否正確。

2、檢查各器件螺絲(si)是否(fou)緊固。

3、用萬用表測(ce)量可控(kong)硅極間電(dian)阻(zu):

●觸發極G與陰極K間(jian)電阻為幾(ji)十(shi)歐姆;

●觸發(fa)極(ji)G與(yu)陽(yang)極(ji)A間電阻(zu)大于幾十千(qian)歐;

●陰極K與陽極A間電阻大于幾十千歐;

●陰極K與陽極A用萬用表200K檔測量,阻值應從小變化到(dao)無限(xian)大。

4、合上(shang)起動柜電源(yuan),進相(xiang)器背面(mian)的接觸器KM11應吸合,短接225、227;合上(shang)進相(xiang)器電源(yuan),電源(yuan)指示(shi)(shi)燈(deng)亮;控(kong)制器應有(you)電,控(kong)制器上(shang)指示(shi)(shi)燈(deng)亮。

5、控(kong)制器上撥碼開(kai)關打在ON(上方)位置,中間主板(ban)(ban)L1、L2、L3循(xun)環亮或滅,L4~L8全亮;兩邊兩塊(kuai)驅動板(ban)(ban)指(zhi)示燈閃爍。

6、按綠(lv)色進相(xiang)按鈕,進相(xiang)器(qi)前面(mian)的(de)接(jie)觸(chu)器(qi)KM13吸合,延時(shi)后,背面(mian)的(de)接(jie)觸(chu)器(qi)KM11斷開,綠(lv)色進相(xiang)指示燈亮,風機運轉,風應向(xiang)上吹(chui),主變壓(ya)器(qi)副邊電流不超過30A,并且沒有大幅度變化。

7、按紅(hong)色(se)退相(xiang)按鈕(niu),進相(xiang)器后面的接觸器KM11吸合,延時后,前面的接觸器KM13斷開(kai),綠色(se)進相(xiang)指示燈滅(mie),紅(hong)色(se)電源(yuan)指示燈亮,進相(xiang)器即(ji)退出進相(xiang)狀態。

8、通(tong)電試驗結(jie)束,請(qing)務必斷開225、227。

(三)調試

1、運行前(qian):控制器主板上撥(bo)碼開關應打(da)在OFF(下方)位置。

2、起(qi)動主電(dian)機(ji):打(da)開進(jin)相器前柜門,合上空氣開關,進(jin)相器電(dian)源(yuan)接(jie)通,面板上的紅色電(dian)源(yuan)指(zhi)示燈亮(liang),關閉柜門,等待主機(ji)起(qi)動。

3、進相(xiang)(xiang):(1)電機(ji)正常運轉(zhuan)后,按綠(lv)色進相(xiang)(xiang)按鈕(niu),進相(xiang)(xiang)器(qi)前面(mian)(mian)的接觸器(qi)KM13吸合(he),延時后,背(bei)面(mian)(mian)的接觸器(qi)KM11斷開,綠(lv)色進相(xiang)(xiang)指(zhi)示燈(deng)亮,風(feng)機(ji)運轉(zhuan),定(ding)子電流(liu)應(ying)下降(jiang),功率因數應(ying)上升(sheng)。如(ru)果定(ding)子電流(liu)不下降(jiang)反而上升(sheng),調整(zheng)同步(bu)變壓器(qi)上6V、6V0兩線的位置,再進相(xiang)(xiang)。

(2)測(ce)量主(zhu)變壓(ya)器原、副邊電流,應無大幅(fu)度擺(bai)動(dong)。

(3)電(dian)機定子電(dian)流應平穩,無大幅(fu)度擺動(dong)。

(4)六個電抗器上端銅排的電流擺動(dong)幅度(du)應一致(zhi)。

4、退相(xiang):按(an)紅色(se)退相(xiang)按(an)鈕,進(jin)相(xiang)器(qi)后(hou)面的接觸器(qi)KM11吸合,延時后(hou),前面的接觸器(qi)KM13斷開(kai),綠色(se)進(jin)相(xiang)指示(shi)燈滅,紅色(se)電源指示(shi)燈亮,進(jin)相(xiang)器(qi)即退出進(jin)相(xiang)狀態。

5、停車(che):進相(xiang)(xiang)器退相(xiang)(xiang)后(hou),按下(xia)主機(ji)停車(che)按鈕,電機(ji)即停車(che)。

(四(si))測量和觀察

1、測量可控硅、銅(tong)排、交流接觸器(qi)、電抗器(qi)、主變(bian)壓器(qi)、控制(zhi)板溫度。

2、測量(liang)可控硅觸發電壓;主(zhu)變壓器一次(ci)、二次(ci)電流;電抗(kang)器輸入電流。

3、觀察風機運行情況。

4、觀察整(zheng)體運行情況(kuang),有(you)無異常響聲或銅(tong)排有(you)無大的抖動現象等。

十(shi)使用維護

為確保TP系列靜止式進相器長期安全、可靠地運行,請操作人員(yuan)特別注(zhu)意以下(xia)事項:

1、嚴禁在(zai)進相器運(yun)行(xing)期間,切斷進相器外部電源(yuan)。

2、定期檢查(cha)冷卻風機運轉(zhuan)狀況,冷卻風機停轉(zhuan)使可(ke)控(kong)(kong)硅散熱(re)能力下(xia)降,可(ke)能燒壞可(ke)控(kong)(kong)硅。

3、定期檢(jian)測主變壓器原、副(fu)邊運行電(dian)流。

4、定期檢測可控硅(gui)、聯接(jie)(jie)銅排、交流接(jie)(jie)觸器(qi)、電抗(kang)器(qi)、主變壓器(qi)、控制板(ban)的溫度(du)。

5、定期檢(jian)修主回路接(jie)觸(chu)(chu)器的觸(chu)(chu)頭。真空(kong)接(jie)觸(chu)(chu)器定期檢(jian)測絕(jue)緣電(dian)(dian)阻,用(yong)5KV或2.5KV搖表(biao)檢(jian)查,當開關管絕(jue)緣電(dian)(dian)阻小于100兆歐(ou)時,應(ying)加(jia)強監視,小于20兆歐(ou)時應(ying)立即更換新管,以延長(chang)接(jie)觸(chu)(chu)器的使用(yong)壽命,保障進相(xiang)器及電(dian)(dian)機安(an)全運行。

6、當進相器停用(yong)一段時間又重新啟用(yong)時, 次進相前(qian)應(ying)觀察柜內控制單元上各指示燈是否正常。電機起動并正常運轉后,各指示燈顯示如(ru)下(xia):

·主板(中間一塊(kuai)):除L1,L2,L3周期性(xing)循環顯示外(注意:此(ci)指(zhi)電機在運轉(zhuan)時的狀(zhuang)態(tai),若電機未轉(zhuan),該三燈為隨(sui)機狀(zhuang)態(tai)),其它各燈均(jun)亮。

·驅動扳(兩(liang)邊的兩(liang)塊):其上面各指示燈均亮(liang)并有輕微閃爍。

7、當電機(ji)定子電流出(chu)現異常大(da)幅擺動時,應立(li)即退(tui)相,查(cha)出(chu)原(yuan)因并(bing)檢修后(hou)投入(ru)使用。

8、定(ding)期打掃柜內衛生(sheng)。

十一故障處理



主電機不(bu)能起動

端子363、369無380V 電源

檢查起(qi)動(dong)柜控(kong)制電源

 

接觸器KM11不吸合

檢查KM11線包及其控制回路

 

接觸器KM11吸合,但其輔助觸點未閉合

檢修(xiu)其輔(fu)助觸(chu)點

 

端子359、361串入合閘回路的線未接通

檢查該回路

不能投(tou)入進相(xiang)

空氣開關QF1、QF2、QF3沒合上

合上空氣(qi)開關

 

按鈕STP、ST接觸不良

 

 

中間繼電器KA11觸點接觸不良

 

 

主電機起動柜內星點接觸器常開輔助觸點不能閉合(225、227未接通)

檢修該接觸器(qi)輔(fu)助觸點及連(lian)線(xian)

 

KM13不(bu)能吸合

檢查KM13線包及其控制回路

 

固態繼電器FV損壞或者不導通

控制器主控制板L6燈滅

檢查主控板7腳對11、12、13腳有無+、-3伏左右電壓,否則更換電流傳感器

 

 

檢查固態繼電器FV

FV的3、4腳有(you)直(zhi)流15V電壓,而323、325不通,須更換該繼(ji)電器

進相(xiang)后主電機(ji)停機(ji)

接入開關柜的KM11、KM13的輔助觸點359、361接觸不好

維修該觸點(dian)

 

進(jin)(jin)相器投入(ru)進(jin)(jin)相瞬間(jian)外部空氣開(kai)關跳(tiao)閘

更換大(da)規(gui)格的空氣開關

進相后無效果(guo)

接入(ru)主(zhu)控板的電流傳(chuan)感(gan)器信號線錯誤

電流傳感器從左到右TA1、TA2、TA3的信號線應分別對應與主控板的13、12、11腳

 

主(zhu)控板的撥碼開(kai)關在(zai)自檢位

撥(bo)碼開關(guan)撥(bo)至工作(zuo)位

 

KM13吸合(he)后KM11未(wei)釋放(時(shi)間繼電器KT11壞)

更換KT11時間繼電器

 

KM15沒有(you)吸合

KM11的輔助(zhu)觸點(dian)301、305接觸不良

維修該(gai)觸點

 

 

KM15線(xian)圈故障

更換KM15線圈

 

KM15主(zhu)觸(chu)點(dian)接觸(chu)不良(liang)

更換KM15

 

主(zhu)變壓器(qi)原(yuan)邊開路(lu)

更換主變壓器

進(jin)相后(hou)主電機電流(liu)不減反增

同步電源相序錯誤

調換進相器內小變壓器TC上輸出6V、6V0電壓的兩線位置

 

電機轉速下降(缺相),自動退相

KM13主觸(chu)點接觸(chu)不良

維(wei)修該(gai)觸點

 

 

電機(ji)轉子線松動,進相(xiang)時(shi)的(de)電流沖擊導致缺相(xiang)

檢查(cha)電機(ji)轉子線

進相后(hou)主電機電流擺動大

可控硅擊穿

測量可控硅極間電阻(詳細方法(fa)見(jian)調試部分)

 

觸發(fa)板損壞(huai)

測量可控硅控制極與陰極之間應有0.2V以上的直流電壓信號,否則應檢查觸發板

 

主板的(de)撥(bo)碼開(kai)關在自檢位(wei)

撥碼開關撥至工作位

 

電機轉子線松動

檢查電機(ji)轉子線(xian)

 

KM13采用節能型線圈時,線圈故障導致KM13進行瞬間來回釋放、吸合,導致主回路接觸不良

維修或更換KM13線圈





注意(yi):進相器檢修不得在進相狀(zhuang)態下進行(xing),發現問題應立即退(tui)相。

十二控制板檢修



現象

原因

對策

L1L2L3不循環閃爍,L6滅,其它各燈正常

轉子缺相

檢查接觸器KM2主觸頭是否損壞,若損壞,則維修觸頭或更換接觸器

電(dian)流(liu)傳(chuan)感器器損壞

檢查電流傳感器是否有±2V以上的輸出信號,否則更換傳感器

主控板元器件(jian)損(sun)壞

依次更換IC210IC211

L1L2L3不周期性閃爍,其它各燈正常

主控板元器件損壞(huai)

依次更換IC210IC211IC205IC207

L6滅,其它各燈正常

主控板元器件損壞

依次更換IC207IC209

L5滅,其它各燈正常

散熱器溫度檢測回路故障

檢查溫(wen)度(du)開關及(ji)其(qi)連線

L4L7L8全部或部分滅

電(dian)源故障

1、檢查變壓器及控制板是否有±18V電源

2、更換相應的780578157915

F1-L1L6 F2-L1L6部分指示燈亮,主板各燈正常

觸發板元器(qi)件(jian)損(sun)壞

1、有一片ULN2004損壞,更換之

2、脈沖變壓器接觸不良,作相應處理

F1-L1L6 F2-L1L6指示燈全滅,主板各燈正常

觸發板(ban)元(yuan)器件損(sun)壞

1、兩片ULN2004損壞,更換之

2、更換555芯片

觸發板無電源

1、檢查主板7815是否有虛焊

2、檢查觸發板19腳與主板6腳連接是否正常





十三注(zhu)意(yi)事(shi)項

1、進相(xiang)器(qi)檢(jian)修應(ying)在退相(xiang)狀態(tai)下進行,發(fa)現(xian)問(wen)題應(ying)立即(ji)退相(xiang)。

2、嚴禁隨意(yi)帶電插拔控(kong)(kong)制板,檢修控(kong)(kong)制板時,一定要把空開QF3打下來(lai)。

3、更換(huan)可控(kong)(kong)硅(gui)(gui)時應注意陰(yin)、陽(yang)極的(de)(de)方向,并(bing)壓緊散熱器(qi)(壓力不要過(guo)大(da)),裝上后擰緊所有(you)螺(luo)絲,之后再檢測可控(kong)(kong)硅(gui)(gui)各極間(jian)的(de)(de)電阻情況(kuang)。若一只可控(kong)(kong)硅(gui)(gui)擊穿(chuan)在柜體上直接檢測,同一相的(de)(de)四個可控(kong)(kong)硅(gui)(gui)均顯示(shi)擊穿(chuan),此時應把該組可控(kong)(kong)硅(gui)(gui)間(jian)的(de)(de)聯接銅排拆掉再測 。

十四(si)訂貨須知

1、提供電(dian)機型號、額(e)定(ding)(ding)(ding)功(gong)率、定(ding)(ding)(ding)子(zi)電(dian)壓(ya)、定(ding)(ding)(ding)子(zi)電(dian)流、轉子(zi)電(dian)壓(ya)、轉子(zi)電(dian)流、額(e)定(ding)(ding)(ding)功(gong)率因數。

2、提(ti)供電機拖動(dong)負(fu)載的(de)特征及負(fu)載率(lv)。

預知TP系列無環流靜止式進相器的更多信息,請(qing)撥(bo)打襄(xiang)陽拓(tuo)邦電氣(qi)官(guan)網電話(hua): 鄭經(jing)理17771133316或咨(zi)詢(xun)網站客服!!

在線留言

LEAVE A MESSAGE