欧美最猛性XXXXX69交_亚洲精品无码永久电影在线_欧美黑人粗大xxxxbbbb_中文字幕日韩精品有码视频

海門產品中心
海門產品中心

海門產品中心

product

海門TP系列靜止式進相器

一概述TP系列無環流靜止式(shi)(shi)進(jin)相(xiang)器(qi)是(shi)襄陽(yang)拓(tuo)邦(bang)電氣自(zi)選研制開發的新(xin)一代高新(xin)技術產品,是(shi)一種專為大中(zhong)型繞線(xian)式(shi)(shi)異……

相關內容
在線留言
詳情內容
content details

TP系列無環流靜止式進相器是襄陽拓(tuo)邦電(dian)(dian)(dian)(dian)氣自(zi)(zi)選(xuan)研制開(kai)發(fa)的新(xin)(xin)一代高(gao)新(xin)(xin)技術產(chan)品,是一種專為大中型繞線式(shi)異步電(dian)(dian)(dian)(dian)動機(ji)設計制作的就地(di)無功(gong)(gong)(gong)功(gong)(gong)(gong)率補償裝置。它串接于電(dian)(dian)(dian)(dian)機(ji)轉子(zi)(zi)回路,改(gai)變(bian)轉子(zi)(zi)電(dian)(dian)(dian)(dian)流與轉子(zi)(zi)電(dian)(dian)(dian)(dian)壓的相位關系,通過磁場進而改(gai)變(bian)電(dian)(dian)(dian)(dian)機(ji)定子(zi)(zi)電(dian)(dian)(dian)(dian)流與電(dian)(dian)(dian)(dian)壓的相位關系,達到提高(gao)電(dian)(dian)(dian)(dian)機(ji)自(zi)(zi)身功(gong)(gong)(gong)率因數、降低電(dian)(dian)(dian)(dian)機(ji)定子(zi)(zi)電(dian)(dian)(dian)(dian)流和溫升的目的。這種方式(shi)從根(gen)本上(shang)改(gai)善(shan)了電(dian)(dian)(dian)(dian)機(ji)的運行(xing)狀況,顯著降低電(dian)(dian)(dian)(dian)機(ji)及電(dian)(dian)(dian)(dian)網的無功(gong)(gong)(gong)損耗,對節能降耗、降低單位產(chan)品成本,提高(gao)企(qi)業的經濟(ji)效(xiao)益具有重要的意義。


TP系列無(wu)環(huan)流(liu)靜止式(shi)進相器對(dui)無(wu)功功率的(de)補(bu)償(chang)(chang)與(yu)電(dian)(dian)機(ji)(ji)定子側并聯電(dian)(dian)容器的(de)補(bu)償(chang)(chang)有(you)著本質的(de)區別。電(dian)(dian)容補(bu)償(chang)(chang)只是在(zai)電(dian)(dian)機(ji)(ji)之外的(de)電(dian)(dian)網上對(dui)無(wu)功進行補(bu)償(chang)(chang),減少(shao)電(dian)(dian)網的(de)無(wu)功輸入(ru),電(dian)(dian)網的(de)功率因數得到(dao)提高,但是電(dian)(dian)機(ji)(ji)的(de)無(wu)功消耗并沒有(you)減少(shao),無(wu)法改善電(dian)(dian)機(ji)(ji)本身的(de)運行狀(zhuang)況;而TP系列靜止式進相器是串(chuan)接在電(dian)機(ji)轉子(zi)回(hui)路(lu)中,不僅(jin)可顯(xian)(xian)著提(ti)高(gao)功率(lv)因(yin)數(shu),使(shi)電(dian)機(ji)定(ding)子(zi)電(dian)流(liu)大幅度降低,而且電(dian)機(ji)溫升(sheng)明顯(xian)(xian)降低,電(dian)機(ji)的效(xiao)率(lv)和過載能力顯(xian)(xian)著提(ti)高(gao)。

TP系(xi)列靜(jing)止式(shi)進(jin)(jin)相(xiang)器與自激(ji)(旋轉)式(shi)進(jin)(jin)相(xiang)機(ji)也(ye)不同(tong)。TP系(xi)列靜(jing)止式(shi)進(jin)(jin)相(xiang)器采用了(le) 的(de)(de)交(jiao)-交(jiao)變頻技(ji)(ji)術和微(wei)機(ji)、可控硅(gui)控制(zhi)技(ji)(ji)術,可自動(dong)跟蹤電機(ji)運行(xing)狀態的(de)(de)變化并自動(dong)調整(zheng)相(xiang)關參數以(yi)達到佳的(de)(de)補償效果,這是(shi)自激(ji)式(shi)進(jin)(jin)相(xiang)機(ji)無法做到的(de)(de)。而且,TP系(xi)列靜(jing)止式(shi)進(jin)(jin)相(xiang)器從根本上克(ke)服了(le)自激(ji)式(shi)進(jin)(jin)相(xiang)機(ji)“整(zheng)流(liu)子”結構(gou)特別怕(pa)塵(chen)埃、壽命短、維修頻繁的(de)(de)缺(que)點;具有(you)參數調節容易、主(zhu)回路無轉動(dong)部件、不怕(pa)灰(hui)塵(chen)、可靠性高(gao)、使用壽命長(chang)、維護方便(bian),是(shi)理想(xiang)的(de)(de)取代自激(ji)式(shi)進(jin)(jin)相(xiang)機(ji)的(de)(de)新型(xing)高(gao)科(ke)技(ji)(ji)產品。

TP系(xi)列靜止式進相器可廣泛用于水泥、化工、礦(kuang)山、冶金、鋼鐵、造紙、制(zhi)藥(yao)等行業的(de)大(da)中型高低壓(ya)繞線式異步電機(ji)。


二(er)型號(hao)命名

TP系列靜止式進相器型號命名(ming)方法如(ru)下:





型號:TP-800,表示適用于額定轉子電流不超過800A的電機(ji)的靜止式進相(xiang)器。


三工(gong)作原理(li)

當電(dian)(dian)(dian)(dian)機(ji)運(yun)行進(jin)相(xiang)時,進(jin)相(xiang)器通過轉(zhuan)子(zi)(zi)(zi)電(dian)(dian)(dian)(dian)流傳(chuan)感器采集(ji)到的(de)(de)(de)(de)轉(zhuan)子(zi)(zi)(zi)電(dian)(dian)(dian)(dian)流信號及工頻電(dian)(dian)(dian)(dian)壓提供的(de)(de)(de)(de)同步信號經(jing)微處理(li)器CPU進(jin)行數據和(he)(he)相(xiang)位處理(li),控(kong)制(zhi)可(ke)控(kong)硅(gui)的(de)(de)(de)(de)觸發信號,調整(zheng)由12只晶閘管(guan)組成的(de)(de)(de)(de)交(jiao)—交(jiao)變頻裝置,將降(jiang)壓后(hou)的(de)(de)(de)(de)工頻電(dian)(dian)(dian)(dian)源變為和(he)(he)轉(zhuan)子(zi)(zi)(zi)電(dian)(dian)(dian)(dian)流同頻率(lv),相(xiang)位滯后(hou)90°的(de)(de)(de)(de)附加電(dian)(dian)(dian)(dian)勢加在電(dian)(dian)(dian)(dian)機(ji)轉(zhuan)子(zi)(zi)(zi)回(hui)路(lu)中。轉(zhuan)子(zi)(zi)(zi)的(de)(de)(de)(de)電(dian)(dian)(dian)(dian)流和(he)(he)電(dian)(dian)(dian)(dian)壓相(xiang)位因此改變,通過磁場(chang)進(jin)而(er)改變電(dian)(dian)(dian)(dian)機(ji)定子(zi)(zi)(zi)電(dian)(dian)(dian)(dian)流與定子(zi)(zi)(zi)電(dian)(dian)(dian)(dian)壓的(de)(de)(de)(de)相(xiang)位角,使電(dian)(dian)(dian)(dian)機(ji)的(de)(de)(de)(de)功(gong)率(lv)因數提高(gao),得到補償(chang)。

當電機(ji)在某一負載(zai)下(xia)運行時,其(qi)轉子電流為I2e、定子電流為I1e, 向量圖如下(xia)所示。







從電(dian)(dian)機學我們知道,激(ji)磁電(dian)(dian)流Im由(you)(you)關系式Im=I1e-I2e,從向量圖(tu)(tu)可(ke)得出(chu)Im。當進相器的(de)(de)電(dian)(dian)勢疊(die)加在轉子(zi)回路(lu)后,轉子(zi)電(dian)(dian)流的(de)(de)相位變(bian)為圖(tu)(tu)中(zhong)的(de)(de)I2。由(you)(you)于負載(zai)不變(bian),激(ji)磁電(dian)(dian)流Im不變(bian)。此時的(de)(de)定子(zi)電(dian)(dian)流I1由(you)(you)關系式I1=Im+I2從向量圖(tu)(tu)可(ke)得出(chu)I1,如圖(tu)(tu)所(suo)(suo)示。從圖(tu)(tu)中(zhong)可(ke)以(yi)看(kan)出(chu)I1的(de)(de)功率因(yin)數角和幅值都比I1e小,說明電(dian)(dian)機的(de)(de)功率因(yin)數有(you)所(suo)(suo)提(ti)高,定子(zi)電(dian)(dian)流有(you)所(suo)(suo)下降。

進相(xiang)器就是這樣改(gai)變轉子(zi)電(dian)流與轉子(zi)電(dian)壓(ya)的(de)相(xiang)位關系(xi),通過磁場進而(er)改(gai)變電(dian)機(ji)定子(zi)電(dian)流與定子(zi)電(dian)壓(ya)的(de)相(xiang)位關系(xi),減(jian)小功(gong)率(lv)因數(shu)角,終使電(dian)機(ji)本身(shen)的(de)功(gong)率(lv)因數(shu)得以提高,定子(zi)電(dian)流得以下降,達(da)到對電(dian)機(ji)補償(chang)的(de)目的(de)。

當(dang)負載發(fa)生(sheng)改變時,微(wei)處理(li)器實時檢測電機(ji)參(can)數的(de)變化(hua)(hua),并根據負載的(de)變化(hua)(hua),動態調整附加在(zai)(zai)轉子(zi)上的(de)電勢幅值,以(yi)使電機(ji)的(de)功率因數始終保(bao)持在(zai)(zai)期(qi)望值上。

四原(yuan)理框圖






電容(rong)式補償(chang)的(de)矢量分析(xi):








電容補償和進相(xiang)器補償的(de)原理圖分別如(ru)下:






圖中,將電(dian)(dian)(dian)(dian)機進行(xing)了(le)等效簡(jian)化(hua),R1、X1為(wei)電(dian)(dian)(dian)(dian)機定(ding)子(zi)等效電(dian)(dian)(dian)(dian)路的(de)(de)電(dian)(dian)(dian)(dian)阻和電(dian)(dian)(dian)(dian)感,R2、X2為(wei)電(dian)(dian)(dian)(dian)機轉子(zi)等效電(dian)(dian)(dian)(dian)路的(de)(de)電(dian)(dian)(dian)(dian)阻和電(dian)(dian)(dian)(dian)感,C為(wei)就地補償的(de)(de)電(dian)(dian)(dian)(dian)容,Uf為(wei)進相器的(de)(de)等效電(dian)(dian)(dian)(dian)路,M為(wei)電(dian)(dian)(dian)(dian)機的(de)(de)接線點。

從圖可以看出(chu),靜止式進(jin)相器和電(dian)(dian)容補(bu)(bu)(bu)償(chang)(chang)對(dui)電(dian)(dian)機(ji)的作用點(dian)不(bu)同,電(dian)(dian)容是在電(dian)(dian)機(ji)的前端(duan)定子側進(jin)行補(bu)(bu)(bu)償(chang)(chang),其(qi)補(bu)(bu)(bu)償(chang)(chang)范(fan)圍(wei)(wei)是在補(bu)(bu)(bu)償(chang)(chang)點(dian)的前端(duan);靜止式進(jin)相器串聯在電(dian)(dian)機(ji)的后端(duan),其(qi)補(bu)(bu)(bu)償(chang)(chang)范(fan)圍(wei)(wei)擴大到了電(dian)(dian)機(ji)。

五性(xing)能特點

1、可使電(dian)機的(de)功率因數(shu)提高到0.95以(yi)上(shang),無功功率降低60%以(yi)上(shang)。

2、降低(di)定子電流10%-20%。

3、降(jiang)低線損、銅損20%-30%。

4、電機(ji)溫升降低5%。

5、過載能力和效率大大提高,電機使用壽命延長(chang)。

6、具有故(gu)障(zhang)自動保護功(gong)能(neng),保障(zhang)設(she)備長(chang)期安全運行。

7、操作簡單(dan),安裝調試和維修保養均不影響正(zheng)常生產,半年(nian)內可(ke)收(shou)回成(cheng)本。

六使(shi)用條(tiao)件

1、安裝地點環境溫度≤40℃

2、安(an)裝地點(dian)相對濕度≤90%

3、 安裝地點無(wu)火災(zai)、爆炸危(wei)險(xian)品,無(wu)化學腐蝕及(ji)劇(ju)烈振動。

4、海拔(ba)高(gao)度≤1500M。

5、進(jin)相器柜(ju)(ju)體上方0.5米內應通(tong)風;如無(wu)地溝,須(xu)將進(jin)相器柜(ju)(ju)體架空0.1米。

注:TP系列靜止式進相器應滿足上方(fang)要求的(de)使用條件,襄陽拓邦電氣還(huan)可提供適用于(yu)高原地區(海(hai)拔超過1500米)的(de)靜止式進相器(但(dan)用戶(hu)須事先(xian)特別(bie)申請(qing))。

七技術(shu)參數


相 器 型 號

配 電 機 參 數

額定轉子電流(A

額定功率(KW

TP-400

400

95-800

TP-500

400-500

245-1000

TP-600

500-600

315-1250

TP-800

600-800

630-1600

TP-1000

800-1000

1000-2000

TP-1200

1000-1200

1600-2500

TP-1500

1200-1500

2000以上




八安裝(zhuang)尺寸

1、外型尺(chi)寸圖(tu)






2、安(an)裝基礎(chu)圖







3、規格尺寸表



型號

外形尺寸(MM)

安裝尺寸(MM)

(W)

(D)

(H)

(E)

(F)

螺(luo)孔(kong)

TP400-600

1000

760

2000

780

620

14

TP800-1000

1100

800

2000

880

650

14

TP1200-1500

1200

900

2200

980

750

16



注:隨著產(chan)品不斷更新換代(dai),外形及安(an)裝尺寸(cun)會有所變化,請以具體的產(chan)品為(wei)準。

九安(an)裝(zhuang)調試

(一(yi))安(an)裝(zhuang)

1、將進相(xiang)器搬(ban)到(dao)安裝位置,注意進相(xiang)器柜體底部應與地溝相(xiang)通(tong)或架空,首先是打開柜子的(de)前后門,從上到(dao)下,逐一地擰緊(jin)螺(luo)(luo)絲,防止在運輸過程中螺(luo)(luo)絲松動造成進相(xiang)器不能正常工作。

2、準備好連接【主(zhu)電機轉(zhuan)子至(zhi)進相器(qi)接觸器(qi)KM13的(de)三根(gen)(gen)電纜】、【進相器(qi)接觸器(qi)KM11至(zhi)主(zhu)電機起動柜的(de)三根(gen)(gen)電纜】,其線(xian)徑應能承載(zai)主(zhu)電機轉(zhuan)子額定電流(liu),比好長(chang)度并壓好接頭。

3、進相(xiang)器(qi)上(shang)(shang)的(de)(de)電(dian)(dian)(dian)流(liu)(liu)表、功率因數表是直(zhi)接(jie)從(cong)電(dian)(dian)(dian)機定(ding)子回路(lu)(lu)上(shang)(shang)的(de)(de)電(dian)(dian)(dian)流(liu)(liu)互(hu)感器(qi)、電(dian)(dian)(dian)壓互(hu)感器(qi)取(qu)信號,要(yao)求所用(yong)電(dian)(dian)(dian)流(liu)(liu)互(hu)感器(qi)副邊的(de)(de)額定(ding)電(dian)(dian)(dian)流(liu)(liu)為(wei)(wei)5A、電(dian)(dian)(dian)壓互(hu)感器(qi)副邊的(de)(de)額定(ding)電(dian)(dian)(dian)壓為(wei)(wei)100V,若用(yong)戶現用(yong)的(de)(de)不(bu)滿足該要(yao)求,則須另(ling)行準備符合上(shang)(shang)述要(yao)求的(de)(de)互(hu)感器(qi)。(注(zhu):電(dian)(dian)(dian)壓互(hu)感器(qi)僅適(shi)用(yong)于高壓電(dian)(dian)(dian)機,對低壓電(dian)(dian)(dian)機,進相(xiang)器(qi)電(dian)(dian)(dian)壓信號直(zhi)接(jie)從(cong)定(ding)子回路(lu)(lu)取(qu))

4、新電機須(xu)帶上(shang)(shang)90%以上(shang)(shang)負載并正常運轉(zhuan)后才可調試(shi)進(jin)相(xiang)器,用戶在通(tong)知我方調試(shi)前,應調試(shi)好電機、減速機、磨機等其(qi)它(ta)設備(bei),使其(qi)帶上(shang)(shang)負載正常運轉(zhuan),以免(mian)延誤(wu)進(jin)相(xiang)器調試(shi)時(shi)間。

5、各(ge)聯鎖線意(yi)義(yi)如下:

(225、227)取(qu)自電(dian)機起動柜(ju)星點短接(jie)接(jie)觸器的輔助常開點,只有在電(dian)機起動完畢后,進相器才可以進相。

(355、357)當開關柜(ju)主開關是接觸器時與(yu)(yu)分(fen)閘(zha)按鈕(niu)并聯;是斷路(lu)器時與(yu)(yu)分(fen)閘(zha)按鈕(niu)串聯, 進相狀(zhuang)態(tai)下主電機(ji)不能(neng)停機(ji),只有先退(tui)相才能(neng)停主機(ji)。

(359、361)串入(ru)開關(guan)柜(ju)合(he)閘回路。當KM11吸合(he)時(shi),可以(yi)起(qi)動電機。

(363、369)從起動柜控(kong)制電源引(yin)單相380V,使(shi)KM11與(yu)起動柜控(kong)制回路同時得電。

(30、32)串入主(zhu)電(dian)(dian)機電(dian)(dian)流計量回路;(40、42)并入主(zhu)電(dian)(dian)機電(dian)(dian)壓(ya)(ya)(ya)計量回路。(取(qu)A相電(dian)(dian)流則(ze)取(qu)B,C相電(dian)(dian)壓(ya)(ya)(ya),如此(ci)類推,電(dian)(dian)流和(he)電(dian)(dian)壓(ya)(ya)(ya)不得取(qu)同(tong)相)。

(A、B、C、N)接三(san)相四線(xian)電(dian)源,導線(xian)橫截面(mian)積:TP600以下用(yong)4mm2;TP1000以下用(yong)6mm2;TP1500以下用(yong)10mm2。

6、控制器所有指(zhi)示燈(deng)的(de)含義說明如下:

(1)主(zhu)板(中間一塊)的指示燈(deng)(從上(shang)往下(xia)數)

●L1、L2、L3:電(dian)機(ji)轉(zhuan)子三相(xiang)電(dian)流信號(hao)指(zhi)示(shi)(shi)(電(dian)機(ji)運轉(zhuan)時為循環顯示(shi)(shi)狀(zhuang)(zhuang)態;自(zi)檢試驗時為隨(sui)機(ji)狀(zhuang)(zhuang)態:或(huo)(huo)亮、或(huo)(huo)滅)

●L4:+5V電源指示(保持亮的狀態)

●L5:熱故障(zhang)指示(有熱故障(zhang)時(shi)L5滅)

●L6:缺相及自動故(gu)(gu)障(zhang)保(bao)護指示(有(you)缺相故(gu)(gu)障(zhang)及其它故(gu)(gu)障(zhang)時(shi)L6燈滅(mie))

●L7:+15V電源(yuan)指示(保持亮的狀(zhuang)態(tai))

●L8:-15V電源指示(shi)(保持亮的狀態)

(2)驅動板(兩(liang)邊(bian)兩(liang)塊)

●分別代表(biao)12個可控制硅(gui)的觸發信號(指示(shi)燈均亮,并有規律的閃(shan)爍)

(二)試驗

1、檢查主電纜、聯(lian)鎖線(xian)、儀表線(xian)連接(jie)是否正(zheng)確。

2、檢查(cha)各器件(jian)螺絲是否緊固。

3、用萬(wan)用表測量(liang)可控硅極(ji)間電阻:

●觸發極(ji)G與(yu)陰極(ji)K間電阻為幾十歐姆;

●觸發極G與陽極A間(jian)電阻大(da)于幾十千歐(ou);

●陰(yin)極K與陽極A間電阻大于幾十千歐;

●陰極K與陽極A用(yong)萬用(yong)表200K檔測量,阻值應(ying)從小變化到(dao)無(wu)限大(da)。

4、合上起動柜電(dian)(dian)源,進相器背面的接觸(chu)器KM11應吸合,短接225、227;合上進相器電(dian)(dian)源,電(dian)(dian)源指示(shi)燈(deng)亮;控(kong)制(zhi)器應有電(dian)(dian),控(kong)制(zhi)器上指示(shi)燈(deng)亮。

5、控(kong)制(zhi)器上撥碼開關打(da)在ON(上方)位置,中間主板L1、L2、L3循環(huan)亮或(huo)滅,L4~L8全亮;兩邊兩塊驅動板指示燈(deng)閃爍。

6、按綠色進相按鈕(niu),進相器前面(mian)的(de)接觸(chu)器KM13吸合(he),延(yan)時后,背面(mian)的(de)接觸(chu)器KM11斷開,綠色進相指(zhi)示燈亮,風(feng)機運(yun)轉,風(feng)應向上(shang)吹,主(zhu)變壓(ya)器副邊電流(liu)不超(chao)過(guo)30A,并且沒有大幅度(du)變化。

7、按紅(hong)(hong)色退(tui)相按鈕,進(jin)相器后面的接觸器KM11吸合,延時后,前面的接觸器KM13斷開,綠色進(jin)相指示燈滅,紅(hong)(hong)色電源指示燈亮,進(jin)相器即退(tui)出進(jin)相狀態。

8、通(tong)電試驗結束,請務必斷開(kai)225、227。

(三)調(diao)試

1、運(yun)行前:控制器主板上撥碼開關應打在(zai)OFF(下方)位置(zhi)。

2、起動(dong)(dong)主(zhu)電機:打開進相器(qi)前柜門,合上空氣開關,進相器(qi)電源接(jie)通,面板上的紅色電源指(zhi)示燈亮,關閉柜門,等(deng)待主(zhu)機起動(dong)(dong)。

3、進(jin)(jin)相:(1)電(dian)機(ji)正常運轉(zhuan)后,按(an)綠色進(jin)(jin)相按(an)鈕,進(jin)(jin)相器(qi)(qi)前面的接(jie)觸器(qi)(qi)KM13吸合,延時(shi)后,背面的接(jie)觸器(qi)(qi)KM11斷開,綠色進(jin)(jin)相指示燈亮,風(feng)機(ji)運轉(zhuan),定(ding)子(zi)(zi)電(dian)流應(ying)下降,功(gong)率因數(shu)應(ying)上(shang)升。如果定(ding)子(zi)(zi)電(dian)流不下降反而上(shang)升,調整同步變壓(ya)器(qi)(qi)上(shang)6V、6V0兩線的位置,再進(jin)(jin)相。

(2)測量主變壓器原、副邊電流(liu),應無大(da)幅度擺動。

(3)電(dian)機定(ding)子電(dian)流(liu)應平穩,無大幅度擺動。

(4)六個(ge)電(dian)抗器上(shang)端銅(tong)排的電(dian)流擺動幅度應一(yi)致。

4、退(tui)相(xiang):按紅色(se)退(tui)相(xiang)按鈕,進相(xiang)器后面的接觸(chu)(chu)器KM11吸合(he),延時后,前面的接觸(chu)(chu)器KM13斷開,綠色(se)進相(xiang)指示燈滅,紅色(se)電源指示燈亮,進相(xiang)器即(ji)退(tui)出(chu)進相(xiang)狀態(tai)。

5、停車(che):進(jin)相器(qi)退(tui)相后,按(an)下主機停車(che)按(an)鈕,電機即停車(che)。

(四)測量和觀察

1、測量可控(kong)(kong)硅(gui)、銅排、交流接觸(chu)器(qi)、電抗器(qi)、主變壓器(qi)、控(kong)(kong)制板溫度(du)。

2、測量可控硅觸發電壓;主變壓器一次(ci)、二次(ci)電流;電抗器輸入電流。

3、觀察風機運行情況。

4、觀察整體運(yun)行情況,有無異常(chang)響聲或銅排(pai)有無大的抖(dou)動現象等。

十(shi)使用維護

為確(que)保TP系列靜止式進相器長期安全、可靠(kao)地運(yun)行,請操作人(ren)員特(te)別注意以下事項:

1、嚴禁在進(jin)相器運行期間,切斷進(jin)相器外部電源。

2、定(ding)期檢查冷(leng)卻風機運(yun)轉狀(zhuang)況(kuang),冷(leng)卻風機停(ting)轉使可(ke)(ke)控硅(gui)散熱能(neng)力(li)下降,可(ke)(ke)能(neng)燒壞可(ke)(ke)控硅(gui)。

3、定期檢(jian)測主變壓器原、副邊運行電流。

4、定期檢測(ce)可控(kong)硅、聯接(jie)(jie)銅(tong)排、交流接(jie)(jie)觸器(qi)、電抗器(qi)、主變(bian)壓器(qi)、控(kong)制板(ban)的溫度。

5、定期檢(jian)修(xiu)主(zhu)回路(lu)接(jie)觸器(qi)的觸頭。真(zhen)空接(jie)觸器(qi)定期檢(jian)測絕(jue)緣電(dian)阻,用(yong)5KV或(huo)2.5KV搖表檢(jian)查,當(dang)開關管絕(jue)緣電(dian)阻小于(yu)100兆歐時,應加強監(jian)視,小于(yu)20兆歐時應立即更換新管,以(yi)延長接(jie)觸器(qi)的使用(yong)壽命,保障進相器(qi)及電(dian)機(ji)安全運行(xing)。

6、當(dang)進(jin)相器停用(yong)一段時間又重新啟用(yong)時, 次(ci)進(jin)相前應(ying)觀察(cha)柜(ju)內控制單(dan)元上(shang)各(ge)指(zhi)示(shi)(shi)燈(deng)是否正(zheng)常(chang)。電機起動并正(zheng)常(chang)運轉(zhuan)后,各(ge)指(zhi)示(shi)(shi)燈(deng)顯示(shi)(shi)如下:

·主(zhu)板(中間一塊):除(chu)L1,L2,L3周期性循(xun)環顯(xian)示外(注意(yi):此指(zhi)電機在運(yun)轉(zhuan)(zhuan)時的狀態,若(ruo)電機未轉(zhuan)(zhuan),該(gai)三燈為隨(sui)機狀態),其它(ta)各燈均亮。

·驅動扳(兩邊的兩塊):其上面各指示燈(deng)均(jun)亮并有輕微閃爍。

7、當電(dian)(dian)機(ji)定子電(dian)(dian)流出現異(yi)常大幅擺動時(shi),應立即退相,查出原(yuan)因并檢修后(hou)投入(ru)使用。

8、定(ding)期打掃柜內衛生。

十(shi)一故(gu)障處理



主電機不能(neng)起動(dong)

端子363、369無380V 電源

檢(jian)查起(qi)動(dong)柜控制(zhi)電(dian)源

 

接觸器KM11不吸合

檢查KM11線包及其控制回路

 

接觸器KM11吸合,但其輔助觸點未閉合

檢(jian)修其輔助觸點

 

端子359、361串入合閘回路的線未接通

檢查該(gai)回路

不能投入(ru)進相

空氣開關QF1、QF2、QF3沒合上

合上空氣開關(guan)

 

按鈕STP、ST接觸不良

 

 

中間繼電器KA11觸點接觸不良

 

 

主電機起動柜內星點接觸器常開輔助觸點不能閉合(225、227未接通)

檢修該接(jie)觸器輔(fu)助觸點及連線(xian)

 

KM13不(bu)能吸合

檢查KM13線包及其控制回路

 

固態繼電器FV損壞或者不導通

控制器主控制板L6燈滅

檢查主控板7腳對11、12、13腳有無+、-3伏左右電壓,否則更換電流傳感器

 

 

檢查固態繼電器FV

FV的3、4腳有直流15V電(dian)壓,而323、325不通,須更換該繼電(dian)器

進相后主(zhu)電機(ji)停機(ji)

接入開關柜的KM11、KM13的輔助觸點359、361接觸不好

維修該觸點

 

進相器投入進相瞬間外(wai)部空氣開(kai)關(guan)跳(tiao)閘

更換大規(gui)格的(de)空(kong)氣開關

進相后無效果

接入主控板的電流傳感器信號線錯誤

電流傳感器從左到右TA1、TA2、TA3的信號線應分別對應與主控板的13、12、11腳

 

主控板(ban)的撥(bo)碼開關在自檢位(wei)

撥(bo)碼開關撥(bo)至工作位

 

KM13吸合后(hou)KM11未(wei)釋放(時間繼(ji)電器KT11壞)

更換KT11時間繼電器

 

KM15沒有吸合(he)

KM11的輔助觸點301、305接(jie)觸不良

維修該觸點

 

 

KM15線圈故障

更換KM15線圈

 

KM15主(zhu)觸點接觸不良(liang)

更換KM15

 

主變(bian)壓(ya)器原邊開路(lu)

更換主變壓器

進相(xiang)后主電機電流不(bu)減反(fan)增

同步(bu)電源(yuan)相序錯誤(wu)

調換進相器內小變壓器TC上輸出6V、6V0電壓的兩線位置

 

電機轉速下降(缺(que)相(xiang)(xiang)),自動退相(xiang)(xiang)

KM13主觸點接觸不良(liang)

維修該觸點

 

 

電(dian)機(ji)轉子(zi)線松動,進相時(shi)的電(dian)流沖擊導致缺(que)相

檢查電機轉子線

進相后主電機電流擺動(dong)大(da)

可控(kong)硅(gui)擊(ji)穿

測量可控硅極間電阻(詳細方法見調試部分)

 

觸發板損壞(huai)

測量可控硅控制極與陰極之間應有0.2V以上的直流電壓信號,否則應檢查觸發板

 

主板的撥碼開關(guan)在(zai)自(zi)檢位

撥(bo)碼開(kai)關撥(bo)至工作位(wei)

 

電機轉(zhuan)子線(xian)松動(dong)

檢查電(dian)機(ji)轉子線(xian)

 

KM13采用節能型線圈時,線圈故障導致KM13進行瞬間來回釋放、吸合,導致主回路接觸不良

維修或更換KM13線圈





注意:進相器檢修不得(de)在進(jin)相狀態下進(jin)行,發現(xian)問題應(ying)立即退相。

十(shi)二(er)控制板(ban)檢修



現(xian)象

原因

對策

L1L2L3不循環閃爍,L6滅,其它各燈正常

轉子缺(que)相

檢查接觸器KM2主觸頭是否損壞,若損壞,則維修觸頭或更換接觸器

電流傳(chuan)感器器損壞

檢查電流傳感器是否有±2V以上的輸出信號,否則更換傳感器

主控板元器件損壞

依次更換IC210IC211

L1L2L3不周期性閃爍,其它各燈正常

主控板元器(qi)件損壞

依次更換IC210IC211IC205IC207

L6滅,其它各燈正常

主控板元(yuan)器件損壞

依次更換IC207IC209

L5滅,其它各燈正常

散熱(re)器溫(wen)度檢(jian)測(ce)回路(lu)故障

檢查溫度開(kai)關及其(qi)連線

L4L7L8全部或部分滅

電(dian)源故(gu)障

1、檢查變壓器及控制板是否有±18V電源

2、更換相應的780578157915

F1-L1L6 F2-L1L6部分指示燈亮,主板各燈正常

觸(chu)發(fa)板元器件(jian)損壞(huai)

1、有一片ULN2004損壞,更換之

2、脈沖變壓器接觸不良,作相應處理

F1-L1L6 F2-L1L6指示燈全滅,主板各燈正常

觸發板元器件損壞

1、兩片ULN2004損壞,更換之

2、更換555芯片

觸發板(ban)無電源

1、檢查主板7815是否有虛焊

2、檢查觸發板19腳與主板6腳連接是否正常





十三(san)注意(yi)事項

1、進相(xiang)器(qi)檢修應在退相(xiang)狀態下進行(xing),發(fa)現(xian)問題應立(li)即退相(xiang)。

2、嚴禁(jin)隨意帶電插拔控(kong)制板,檢修(xiu)控(kong)制板時,一定(ding)要把空(kong)開QF3打下來。

3、更換可控硅時應(ying)注意陰、陽極(ji)的方向,并壓(ya)緊散熱器(qi)(壓(ya)力(li)不要(yao)過大),裝上(shang)后擰緊所有螺(luo)絲,之后再檢(jian)測(ce)可控硅各極(ji)間(jian)的電阻情況。若一只可控硅擊(ji)(ji)穿在(zai)柜體上(shang)直(zhi)接檢(jian)測(ce),同一相的四個可控硅均顯示(shi)擊(ji)(ji)穿,此時應(ying)把該組可控硅間(jian)的聯接銅排拆掉再測(ce) 。

十四(si)訂貨須(xu)知

1、提供電(dian)機型(xing)號(hao)、額(e)定(ding)功率(lv)、定(ding)子(zi)(zi)電(dian)壓(ya)、定(ding)子(zi)(zi)電(dian)流、轉子(zi)(zi)電(dian)壓(ya)、轉子(zi)(zi)電(dian)流、額(e)定(ding)功率(lv)因數。

2、提供電機拖(tuo)動負載的(de)特征(zheng)及負載率。

預知TP系列無環流靜止式進相器的更(geng)多信(xin)息(xi),請撥(bo)打襄陽拓邦電氣官網(wang)電話: 鄭經理(li)17771133316或咨詢(xun)網(wang)站客服(fu)!!

在線留言

LEAVE A MESSAGE