TP系列無環流靜止式進相器是(shi)襄陽拓邦(bang)電(dian)(dian)氣自選研制(zhi)開(kai)發的(de)(de)新一代高新技術產品,是(shi)一種專為大中型繞線式異步電(dian)(dian)動(dong)機(ji)(ji)設(she)計制(zhi)作的(de)(de)就地(di)無功(gong)功(gong)率(lv)補償裝置。它串(chuan)接于電(dian)(dian)機(ji)(ji)轉子(zi)回(hui)路,改變轉子(zi)電(dian)(dian)流與轉子(zi)電(dian)(dian)壓(ya)(ya)的(de)(de)相位(wei)關系,通(tong)過磁場(chang)進而改變電(dian)(dian)機(ji)(ji)定子(zi)電(dian)(dian)流與電(dian)(dian)壓(ya)(ya)的(de)(de)相位(wei)關系,達到(dao)提高電(dian)(dian)機(ji)(ji)自身功(gong)率(lv)因數、降(jiang)低(di)(di)電(dian)(dian)機(ji)(ji)定子(zi)電(dian)(dian)流和(he)溫升的(de)(de)目的(de)(de)。這種方式從根(gen)本上(shang)改善了電(dian)(dian)機(ji)(ji)的(de)(de)運行狀況(kuang),顯著降(jiang)低(di)(di)電(dian)(dian)機(ji)(ji)及電(dian)(dian)網的(de)(de)無功(gong)損(sun)耗,對節能降(jiang)耗、降(jiang)低(di)(di)單位(wei)產品成本,提高企(qi)業(ye)的(de)(de)經濟效益具有重要的(de)(de)意義(yi)。
TP系列無(wu)環流靜(jing)止式進相器(qi)對無(wu)功功率(lv)(lv)的(de)(de)補(bu)償與電(dian)(dian)機(ji)定(ding)子側并聯電(dian)(dian)容器(qi)的(de)(de)補(bu)償有著本(ben)(ben)質的(de)(de)區別。電(dian)(dian)容補(bu)償只是(shi)在(zai)電(dian)(dian)機(ji)之外的(de)(de)電(dian)(dian)網(wang)上對無(wu)功進行補(bu)償,減(jian)少電(dian)(dian)網(wang)的(de)(de)無(wu)功輸入(ru),電(dian)(dian)網(wang)的(de)(de)功率(lv)(lv)因數得到提(ti)高,但是(shi)電(dian)(dian)機(ji)的(de)(de)無(wu)功消耗并沒有減(jian)少,無(wu)法改善(shan)電(dian)(dian)機(ji)本(ben)(ben)身的(de)(de)運行狀況(kuang);而TP系列靜止式進相器是串接在電(dian)機轉子(zi)回路(lu)中,不僅可顯著(zhu)提(ti)高功率因數,使(shi)電(dian)機定子(zi)電(dian)流大(da)幅度降低,而且電(dian)機溫升明(ming)顯降低,電(dian)機的效率和過(guo)載能力顯著(zhu)提(ti)高。
TP系列靜(jing)(jing)止(zhi)式(shi)進(jin)(jin)相(xiang)(xiang)器(qi)(qi)與自(zi)(zi)激(ji)(旋轉)式(shi)進(jin)(jin)相(xiang)(xiang)機也不同。TP系列靜(jing)(jing)止(zhi)式(shi)進(jin)(jin)相(xiang)(xiang)器(qi)(qi)采用了 的(de)交(jiao)-交(jiao)變(bian)(bian)頻(pin)技術(shu)和微機、可(ke)控(kong)硅(gui)控(kong)制技術(shu),可(ke)自(zi)(zi)動跟蹤電(dian)機運行狀態的(de)變(bian)(bian)化并(bing)自(zi)(zi)動調(diao)整(zheng)相(xiang)(xiang)關參數以達到(dao)佳的(de)補(bu)償效果,這是(shi)自(zi)(zi)激(ji)式(shi)進(jin)(jin)相(xiang)(xiang)機無法做到(dao)的(de)。而(er)且,TP系列靜(jing)(jing)止(zhi)式(shi)進(jin)(jin)相(xiang)(xiang)器(qi)(qi)從根本(ben)上克服了自(zi)(zi)激(ji)式(shi)進(jin)(jin)相(xiang)(xiang)機“整(zheng)流子(zi)”結構特別怕塵(chen)埃、壽命短、維修(xiu)頻(pin)繁(fan)的(de)缺點;具有參數調(diao)節(jie)容易、主回路無轉動部(bu)件、不怕灰(hui)塵(chen)、可(ke)靠性(xing)高(gao)、使用壽命長(chang)、維護(hu)方便,是(shi)理想(xiang)的(de)取代自(zi)(zi)激(ji)式(shi)進(jin)(jin)相(xiang)(xiang)機的(de)新型高(gao)科技產品。
TP系列(lie)靜止式進相器可廣泛用于水泥、化工、礦山(shan)、冶金、鋼鐵、造紙(zhi)、制藥(yao)等(deng)行業的大中型高低壓繞線式異步電機。
二型號命(ming)名(ming)
TP系列靜止式進相器型號命名方法如下:
型(xing)號(hao):TP-800,表示適(shi)用于額定(ding)轉子電(dian)流不(bu)超過800A的(de)電(dian)機的(de)靜止式進相器。
三工作原理
當電(dian)(dian)(dian)機(ji)運行進(jin)相時(shi),進(jin)相器通過(guo)轉(zhuan)(zhuan)子電(dian)(dian)(dian)流(liu)(liu)傳感器采集到的(de)(de)轉(zhuan)(zhuan)子電(dian)(dian)(dian)流(liu)(liu)信號(hao)及(ji)工頻(pin)電(dian)(dian)(dian)壓提供的(de)(de)同步(bu)信號(hao)經微處理(li)器CPU進(jin)行數據和(he)相位處理(li),控制可控硅的(de)(de)觸發信號(hao),調整由(you)12只(zhi)晶(jing)閘(zha)管組成的(de)(de)交(jiao)—交(jiao)變(bian)(bian)頻(pin)裝置(zhi),將降壓后的(de)(de)工頻(pin)電(dian)(dian)(dian)源變(bian)(bian)為和(he)轉(zhuan)(zhuan)子電(dian)(dian)(dian)流(liu)(liu)同頻(pin)率(lv),相位滯后90°的(de)(de)附加(jia)電(dian)(dian)(dian)勢加(jia)在電(dian)(dian)(dian)機(ji)轉(zhuan)(zhuan)子回路中(zhong)。轉(zhuan)(zhuan)子的(de)(de)電(dian)(dian)(dian)流(liu)(liu)和(he)電(dian)(dian)(dian)壓相位因此改(gai)變(bian)(bian),通過(guo)磁場(chang)進(jin)而改(gai)變(bian)(bian)電(dian)(dian)(dian)機(ji)定(ding)子電(dian)(dian)(dian)流(liu)(liu)與定(ding)子電(dian)(dian)(dian)壓的(de)(de)相位角,使(shi)電(dian)(dian)(dian)機(ji)的(de)(de)功(gong)率(lv)因數提高,得到補償(chang)。
當(dang)電機(ji)在某一負載下(xia)運行(xing)時(shi),其轉子電流為(wei)I2e、定子電流為(wei)I1e, 向量圖如下(xia)所示。
從電(dian)機學我們知道,激磁(ci)電(dian)流(liu)(liu)Im由(you)關系(xi)式Im=I1e-I2e,從向量(liang)圖(tu)可(ke)得出Im。當進相(xiang)器的電(dian)勢疊加在轉子回路后,轉子電(dian)流(liu)(liu)的相(xiang)位(wei)變為圖(tu)中的I2。由(you)于負載(zai)不變,激磁(ci)電(dian)流(liu)(liu)Im不變。此時的定(ding)子電(dian)流(liu)(liu)I1由(you)關系(xi)式I1=Im+I2從向量(liang)圖(tu)可(ke)得出I1,如圖(tu)所(suo)示。從圖(tu)中可(ke)以(yi)看(kan)出I1的功率因(yin)數角和幅值都比I1e小,說明(ming)電(dian)機的功率因(yin)數有所(suo)提高,定(ding)子電(dian)流(liu)(liu)有所(suo)下降。
進相(xiang)器就是這樣(yang)改變(bian)轉子電(dian)(dian)流與(yu)轉子電(dian)(dian)壓(ya)的相(xiang)位(wei)關(guan)系,通過(guo)磁場進而改變(bian)電(dian)(dian)機定(ding)子電(dian)(dian)流與(yu)定(ding)子電(dian)(dian)壓(ya)的相(xiang)位(wei)關(guan)系,減小功(gong)率(lv)因數角,終使電(dian)(dian)機本身(shen)的功(gong)率(lv)因數得以提(ti)高,定(ding)子電(dian)(dian)流得以下降,達到對電(dian)(dian)機補(bu)償的目(mu)的。
當負載發生(sheng)改變(bian)(bian)時(shi),微(wei)處理器(qi)實(shi)時(shi)檢測電(dian)機參數的(de)變(bian)(bian)化,并根據負載的(de)變(bian)(bian)化,動態調整(zheng)附加(jia)在轉(zhuan)子(zi)上的(de)電(dian)勢幅值,以使電(dian)機的(de)功率因數始(shi)終(zhong)保持在期望值上。
四(si)原理框圖
電容式補(bu)償的矢量分析:
電容補(bu)償和進相器補(bu)償的原理圖(tu)分別如下:
圖中,將(jiang)電(dian)機(ji)進行了(le)等(deng)(deng)(deng)效(xiao)簡化,R1、X1為(wei)(wei)電(dian)機(ji)定子等(deng)(deng)(deng)效(xiao)電(dian)路的電(dian)阻和(he)電(dian)感,R2、X2為(wei)(wei)電(dian)機(ji)轉(zhuan)子等(deng)(deng)(deng)效(xiao)電(dian)路的電(dian)阻和(he)電(dian)感,C為(wei)(wei)就地補(bu)償的電(dian)容,Uf為(wei)(wei)進相器的等(deng)(deng)(deng)效(xiao)電(dian)路,M為(wei)(wei)電(dian)機(ji)的接線點。
從圖可以看出(chu),靜止(zhi)式(shi)(shi)進(jin)相(xiang)(xiang)器(qi)和(he)電容(rong)補償對(dui)電機(ji)的作用點不同,電容(rong)是在電機(ji)的前端定(ding)子側進(jin)行補償,其(qi)補償范(fan)圍是在補償點的前端;靜止(zhi)式(shi)(shi)進(jin)相(xiang)(xiang)器(qi)串(chuan)聯在電機(ji)的后端,其(qi)補償范(fan)圍擴(kuo)大(da)到了電機(ji)。
五性能特點
1、可使電機的功(gong)率因(yin)數(shu)提高到0.95以(yi)上,無功(gong)功(gong)率降低60%以(yi)上。
2、降低定子電流10%-20%。
3、降低線(xian)損、銅損20%-30%。
4、電機(ji)溫升降低5%。
5、過載能力和效(xiao)率大大提高,電機使用壽命延(yan)長。
6、具有故障自動保護功(gong)能,保障設備長期(qi)安全運行。
7、操作簡單,安裝(zhuang)調(diao)試和維修保養(yang)均不影響正常(chang)生產,半年內可收回(hui)成本。
六使用條件
1、安(an)裝地點環境溫度≤40℃
2、安裝地點相對濕度(du)≤90%
3、 安裝地點無火災、爆炸危險品,無化學腐蝕(shi)及劇烈振動。
4、海(hai)拔高(gao)度≤1500M。
5、進相器柜體上方0.5米(mi)(mi)內應通風;如無地溝,須將(jiang)進相器柜體架空0.1米(mi)(mi)。
注:TP系列靜止式進(jin)相器應(ying)滿(man)足上方要求(qiu)的使用條(tiao)件,襄陽拓邦電氣還(huan)可提供適用于高原地區(qu)(海拔超過1500米)的(de)靜止式進相器(但用戶須(xu)事先特別(bie)申請)。
七技術參數
進 相 器 型 號 |
適 配 電 機 參 數 |
|
額定轉子電流(A) |
額定功率(KW) |
|
TP-400 |
≤400 |
95-800 |
TP-500 |
400-500 |
245-1000 |
TP-600 |
500-600 |
315-1250 |
TP-800 |
600-800 |
630-1600 |
TP-1000 |
800-1000 |
1000-2000 |
TP-1200 |
1000-1200 |
1600-2500 |
TP-1500 |
1200-1500 |
2000以上 |
八安裝尺寸
1、外(wai)型尺(chi)寸圖
2、安裝基礎圖
3、規格尺(chi)寸表
型號 |
外形尺寸(MM) |
安裝尺寸(MM) |
||||
寬(W) |
深(D) |
高(H) |
寬(E) |
深(F) |
螺(luo)孔(kong) |
|
TP400-600 |
1000 |
760 |
2000 |
780 |
620 |
14 |
TP800-1000 |
1100 |
800 |
2000 |
880 |
650 |
14 |
TP1200-1500 |
1200 |
900 |
2200 |
980 |
750 |
16 |
注:隨著產品不斷更新換代,外形(xing)及安裝尺寸會有所(suo)變(bian)化,請以具體的產品為準。
九安裝(zhuang)調試
(一)安裝
1、將(jiang)進相器(qi)搬到安裝位置,注意(yi)進相器(qi)柜體(ti)底部應(ying)與(yu)地溝(gou)相通或(huo)架空,首(shou)先是打開柜子的前后門,從上到下,逐一地擰(ning)緊螺絲,防止在(zai)運輸(shu)過程(cheng)中(zhong)螺絲松動造(zao)成進相器(qi)不能正常工作。
2、準備好(hao)連接(jie)【主(zhu)電(dian)機轉(zhuan)子(zi)至進相器接(jie)觸器KM13的三根(gen)電(dian)纜】、【進相器接(jie)觸器KM11至主(zhu)電(dian)機起動(dong)柜的三根(gen)電(dian)纜】,其線徑應(ying)能承載主(zhu)電(dian)機轉(zhuan)子(zi)額(e)定電(dian)流,比好(hao)長度并壓(ya)好(hao)接(jie)頭(tou)。
3、進相器(qi)(qi)上的(de)電(dian)(dian)(dian)(dian)流(liu)表、功率(lv)因數表是直接從電(dian)(dian)(dian)(dian)機(ji)定(ding)子回(hui)路(lu)上的(de)電(dian)(dian)(dian)(dian)流(liu)互感器(qi)(qi)、電(dian)(dian)(dian)(dian)壓(ya)互感器(qi)(qi)取信號,要求(qiu)所用(yong)電(dian)(dian)(dian)(dian)流(liu)互感器(qi)(qi)副邊的(de)額定(ding)電(dian)(dian)(dian)(dian)流(liu)為5A、電(dian)(dian)(dian)(dian)壓(ya)互感器(qi)(qi)副邊的(de)額定(ding)電(dian)(dian)(dian)(dian)壓(ya)為100V,若(ruo)用(yong)戶現用(yong)的(de)不滿(man)足該要求(qiu),則須另行準備符合上述要求(qiu)的(de)互感器(qi)(qi)。(注:電(dian)(dian)(dian)(dian)壓(ya)互感器(qi)(qi)僅適(shi)用(yong)于(yu)高(gao)壓(ya)電(dian)(dian)(dian)(dian)機(ji),對低(di)壓(ya)電(dian)(dian)(dian)(dian)機(ji),進相器(qi)(qi)電(dian)(dian)(dian)(dian)壓(ya)信號直接從定(ding)子回(hui)路(lu)取)
4、新電機須帶上(shang)(shang)90%以(yi)(yi)上(shang)(shang)負載(zai)(zai)并正(zheng)常(chang)運轉后才(cai)可調(diao)試(shi)(shi)進(jin)相(xiang)器,用戶在通知(zhi)我(wo)方(fang)調(diao)試(shi)(shi)前,應(ying)調(diao)試(shi)(shi)好電機、減速機、磨機等其它設備(bei),使其帶上(shang)(shang)負載(zai)(zai)正(zheng)常(chang)運轉,以(yi)(yi)免延誤進(jin)相(xiang)器調(diao)試(shi)(shi)時間(jian)。
5、各(ge)聯鎖線意義如下:
(225、227)取自電(dian)機起動(dong)柜星點(dian)短接接觸器的輔助(zhu)常開點(dian),只有在電(dian)機起動(dong)完畢后(hou),進(jin)相器才可以進(jin)相。
(355、357)當開(kai)關柜主(zhu)(zhu)開(kai)關是接觸器(qi)時與分閘(zha)按(an)鈕并(bing)聯;是斷(duan)路(lu)器(qi)時與分閘(zha)按(an)鈕串聯, 進相(xiang)狀態下主(zhu)(zhu)電(dian)機不(bu)能停(ting)機,只有先退(tui)相(xiang)才能停(ting)主(zhu)(zhu)機。
(359、361)串入(ru)開關柜合閘回路。當KM11吸合時,可(ke)以起動電機。
(363、369)從起(qi)(qi)動(dong)柜(ju)控制(zhi)電(dian)源(yuan)引單相380V,使KM11與起(qi)(qi)動(dong)柜(ju)控制(zhi)回(hui)路(lu)同(tong)時得電(dian)。
(30、32)串入(ru)主(zhu)(zhu)電(dian)(dian)機(ji)電(dian)(dian)流計量回(hui)路;(40、42)并(bing)入(ru)主(zhu)(zhu)電(dian)(dian)機(ji)電(dian)(dian)壓(ya)(ya)計量回(hui)路。(取(qu)A相電(dian)(dian)流則取(qu)B,C相電(dian)(dian)壓(ya)(ya),如此類(lei)推,電(dian)(dian)流和(he)電(dian)(dian)壓(ya)(ya)不得取(qu)同相)。
(A、B、C、N)接三相四線(xian)電(dian)源,導(dao)線(xian)橫截面積(ji):TP600以(yi)下(xia)用4mm2;TP1000以(yi)下(xia)用6mm2;TP1500以(yi)下(xia)用10mm2。
6、控制器所有指示燈的(de)含義說明如下:
(1)主板(中間一塊(kuai))的指示(shi)燈(從上往下(xia)數(shu))
●L1、L2、L3:電機(ji)轉子三相電流信號指示(電機(ji)運轉時(shi)為循(xun)環顯(xian)示狀(zhuang)(zhuang)態;自檢試驗時(shi)為隨機(ji)狀(zhuang)(zhuang)態:或(huo)亮、或(huo)滅)
●L4:+5V電(dian)源指(zhi)示(保持亮(liang)的(de)狀(zhuang)態(tai))
●L5:熱故障(zhang)指示(有熱故障(zhang)時L5滅)
●L6:缺相及(ji)(ji)自動故(gu)障保護指示(有缺相故(gu)障及(ji)(ji)其它(ta)故(gu)障時L6燈滅)
●L7:+15V電源指(zhi)示(保持亮(liang)的狀態)
●L8:-15V電源(yuan)指示(保持亮的(de)狀態(tai))
(2)驅動(dong)板(兩邊兩塊)
●分別代(dai)表12個可控制硅的(de)(de)觸發(fa)信號(指示燈均(jun)亮,并有規律的(de)(de)閃爍)
(二)試驗
1、檢查主電纜、聯鎖線、儀(yi)表(biao)線連接是否正(zheng)確。
2、檢查各器件螺絲是否緊(jin)固。
3、用(yong)萬用(yong)表測(ce)量可控硅極(ji)間電阻(zu):
●觸發極(ji)G與(yu)陰極(ji)K間電阻(zu)為幾十歐姆;
●觸發極(ji)G與陽極(ji)A間電阻大于(yu)幾十千歐;
●陰極K與陽(yang)極A間電阻(zu)大(da)于幾十千歐(ou);
●陰(yin)極(ji)K與陽極(ji)A用萬用表200K檔(dang)測(ce)量,阻值應(ying)從小變化到無限大。
4、合上(shang)起動(dong)柜電源(yuan),進相器背面(mian)的接(jie)觸器KM11應吸合,短接(jie)225、227;合上(shang)進相器電源(yuan),電源(yuan)指示燈亮;控制器應有電,控制器上(shang)指示燈亮。
5、控制(zhi)器上(shang)撥碼開關打(da)在(zai)ON(上(shang)方)位置(zhi),中間主板(ban)L1、L2、L3循(xun)環亮或滅,L4~L8全(quan)亮;兩邊兩塊驅動板(ban)指示燈閃(shan)爍。
6、按(an)綠色進相按(an)鈕,進相器(qi)前面(mian)的接(jie)觸(chu)器(qi)KM13吸合(he),延時后(hou),背(bei)面(mian)的接(jie)觸(chu)器(qi)KM11斷開,綠色進相指示(shi)燈(deng)亮,風機運轉,風應向(xiang)上(shang)吹,主(zhu)變壓器(qi)副邊電(dian)流不超(chao)過(guo)30A,并且沒有大(da)幅度變化。
7、按紅色(se)退(tui)相(xiang)(xiang)按鈕,進(jin)相(xiang)(xiang)器(qi)后面的(de)接(jie)觸器(qi)KM11吸合,延(yan)時(shi)后,前面的(de)接(jie)觸器(qi)KM13斷開,綠色(se)進(jin)相(xiang)(xiang)指示燈滅,紅色(se)電(dian)源指示燈亮,進(jin)相(xiang)(xiang)器(qi)即(ji)退(tui)出進(jin)相(xiang)(xiang)狀態。
8、通電(dian)試驗結(jie)束(shu),請務(wu)必斷(duan)開225、227。
(三)調試
1、運行前(qian):控(kong)制(zhi)器主板(ban)上撥碼開(kai)關(guan)應打在OFF(下方)位置。
2、起動主(zhu)電(dian)機:打(da)開(kai)(kai)進相器(qi)前柜門(men),合上(shang)空氣開(kai)(kai)關,進相器(qi)電(dian)源(yuan)(yuan)接通,面板上(shang)的(de)紅色電(dian)源(yuan)(yuan)指示燈亮,關閉柜門(men),等待主(zhu)機起動。
3、進相:(1)電機正常(chang)運(yun)轉后,按綠色進相按鈕,進相器(qi)前面的(de)接觸(chu)器(qi)KM13吸合,延時后,背面的(de)接觸(chu)器(qi)KM11斷開,綠色進相指(zhi)示(shi)燈亮,風機運(yun)轉,定(ding)子電流應下降,功率因數應上升。如果定(ding)子電流不下降反而(er)上升,調整同步變壓(ya)器(qi)上6V、6V0兩線的(de)位置,再進相。
(2)測量(liang)主變壓器原、副邊電流(liu),應無大幅度擺(bai)動。
(3)電機定子(zi)電流應平穩(wen),無大幅度(du)擺動。
(4)六個電抗器上端銅排的電流擺動(dong)幅度應(ying)一致。
4、退(tui)相(xiang):按紅色退(tui)相(xiang)按鈕,進(jin)(jin)相(xiang)器后面的接(jie)(jie)觸(chu)器KM11吸合,延(yan)時后,前(qian)面的接(jie)(jie)觸(chu)器KM13斷開,綠色進(jin)(jin)相(xiang)指(zhi)示(shi)燈滅,紅色電源指(zhi)示(shi)燈亮,進(jin)(jin)相(xiang)器即退(tui)出進(jin)(jin)相(xiang)狀態(tai)。
5、停車:進相器退相后,按下主機(ji)(ji)停車按鈕,電(dian)機(ji)(ji)即停車。
(四)測量和(he)觀察
1、測量可控硅、銅(tong)排、交流接觸器、電(dian)抗器、主變壓器、控制板溫度。
2、測量可控硅(gui)觸(chu)發電壓;主變壓器一(yi)次、二次電流;電抗器輸入(ru)電流。
3、觀察(cha)風機(ji)運(yun)行情(qing)況。
4、觀察整體運行情況,有無(wu)異(yi)常響聲或銅排有無(wu)大的(de)抖動現象(xiang)等(deng)。
十使(shi)用維護
為確保(bao)TP系列靜止式進相器長期安全、可靠地運行,請操作人員特別注意以下事項:
1、嚴禁在進相(xiang)器(qi)運(yun)行期(qi)間,切斷進相(xiang)器(qi)外部電(dian)源。
2、定期檢查冷卻風(feng)機(ji)(ji)運轉(zhuan)狀況,冷卻風(feng)機(ji)(ji)停(ting)轉(zhuan)使可控(kong)硅(gui)散熱(re)能(neng)力下降,可能(neng)燒(shao)壞可控(kong)硅(gui)。
3、定(ding)期(qi)檢測(ce)主變(bian)壓器原(yuan)、副邊(bian)運(yun)行電流。
4、定期檢測可控硅、聯接銅排(pai)、交流接觸器(qi)(qi)、電抗器(qi)(qi)、主變壓器(qi)(qi)、控制板的溫(wen)度(du)。
5、定期檢修主回路(lu)接(jie)觸(chu)(chu)器(qi)的觸(chu)(chu)頭(tou)。真(zhen)空接(jie)觸(chu)(chu)器(qi)定期檢測絕(jue)緣電阻,用5KV或2.5KV搖表檢查(cha),當開關管(guan)絕(jue)緣電阻小(xiao)于100兆歐(ou)時,應(ying)加強(qiang)監視,小(xiao)于20兆歐(ou)時應(ying)立即更(geng)換新管(guan),以延(yan)長接(jie)觸(chu)(chu)器(qi)的使用壽(shou)命,保障進相器(qi)及(ji)電機安(an)全運(yun)行。
6、當進(jin)相器停用一(yi)段(duan)時(shi)間又重(zhong)新啟用時(shi), 次進(jin)相前應觀(guan)察柜內控(kong)制單元(yuan)上各指(zhi)示燈是否正常(chang)。電機起動(dong)并(bing)正常(chang)運轉后,各指(zhi)示燈顯示如下:
·主板(中間(jian)一(yi)塊):除L1,L2,L3周期(qi)性循環顯示外(注意:此指(zhi)電機(ji)在運轉時的狀態,若(ruo)電機(ji)未轉,該(gai)三(san)燈為隨機(ji)狀態),其它(ta)各燈均(jun)亮。
·驅動扳(ban)(兩邊(bian)的(de)兩塊):其上面各(ge)指示燈均亮(liang)并有輕微(wei)閃爍。
7、當電機定(ding)子電流出現異常大幅擺動時,應立即退相,查出原因并檢修后投入使用。
8、定期打掃柜內衛生。
十一故障處理
主電機(ji)不能起動 |
端子363、369無380V 電源 |
檢查起動(dong)柜(ju)控制電(dian)源(yuan) |
||
|
接觸器KM11不吸合 |
檢查KM11線包及其控制回路 |
||
|
接觸器KM11吸合,但其輔助觸點未閉合 |
檢修其輔(fu)助觸點 |
||
|
端子359、361串入合閘回路的線未接通 |
檢(jian)查該回路 |
||
不能投入進相 |
空氣開關QF1、QF2、QF3沒合上 |
合上空氣開(kai)關 |
||
|
按鈕STP、ST接觸不良 |
|
||
|
中間繼電器KA11觸點接觸不良 |
|
||
|
主電機起動柜內星點接觸器常開輔助觸點不能閉合(225、227未接通) |
檢修該接觸器輔(fu)助觸點及連線(xian) |
||
|
KM13不能吸合 |
檢查KM13線包及其控制回路 |
||
|
固態繼電器FV損壞或者不導通 |
控制器主控制板L6燈滅 |
檢查主控板7腳對11、12、13腳有無+、-3伏左右電壓,否則更換電流傳感器 |
|
|
|
檢查固態繼電器FV |
FV的3、4腳有直流15V電(dian)壓,而323、325不通,須更換該繼電(dian)器 |
|
進相后主電機停(ting)機 |
接入開關柜的KM11、KM13的輔助觸點359、361接觸不好 |
維修該(gai)觸點 |
||
|
進相器投入進相瞬間外部空氣開關跳閘 |
更換大(da)規(gui)格(ge)的空氣(qi)開關 |
||
進相后(hou)無效果 |
接(jie)入主(zhu)控板的(de)電流傳感(gan)器信號線(xian)錯誤 |
電流傳感器從左到右TA1、TA2、TA3的信號線應分別對應與主控板的13、12、11腳 |
||
|
主控板的撥碼開關(guan)在自檢位 |
撥(bo)碼開關撥(bo)至工作位 |
||
|
KM13吸合后(hou)KM11未釋放(時間繼電器KT11壞) |
更換KT11時間繼電器 |
||
|
KM15沒有吸合(he) |
KM11的輔助(zhu)觸(chu)點301、305接(jie)觸(chu)不良 |
維修該觸點 |
|
|
|
KM15線圈故(gu)障(zhang) |
更換KM15線圈 |
|
|
KM15主觸點(dian)接(jie)觸不良 |
更換KM15 |
||
|
主變壓器原邊開路 |
更換主變(bian)壓器 |
||
進(jin)相后主電機電流不減反增 |
同步電(dian)源(yuan)相序錯誤 |
調換進相器內小變壓器TC上輸出6V、6V0電壓的兩線位置 |
||
|
電(dian)機(ji)轉速下(xia)降(缺相),自動(dong)退相 |
KM13主觸點接觸不良 |
維(wei)修該觸(chu)點 |
|
|
|
電機轉子線松動(dong),進相時的電流沖擊導致缺(que)相 |
檢(jian)查電機轉子線 |
|
進相后主(zhu)電機電流擺動大 |
可(ke)控硅擊(ji)穿 |
測量可控(kong)硅極(ji)間電阻(詳(xiang)細方法見調試部分) |
||
|
觸發板(ban)損壞 |
測量可控硅控制極與陰極之間應有0.2V以上的直流電壓信號,否則應檢查觸發板 |
||
|
主板的撥碼開關在自(zi)檢位 |
撥(bo)碼(ma)開關撥(bo)至工(gong)作(zuo)位 |
||
|
電機轉子線松(song)動 |
檢(jian)查電(dian)機轉子線 |
||
|
當KM13采用節能型線圈時,線圈故障導致KM13進行瞬間來回釋放、吸合,導致主回路接觸不良 |
維修或更換KM13線圈 |
注(zhu)意:進相器檢修不得在進(jin)相(xiang)狀態下進(jin)行,發(fa)現問題(ti)應立即(ji)退相(xiang)。
十二控制板檢修(xiu)
現象 |
原因(yin) |
對(dui)策 |
L1、L2、L3不循環閃爍,L6滅,其它各燈正常 |
轉子缺(que)相 |
檢查接觸器KM2主觸頭是否損壞,若損壞,則維修觸頭或更換接觸器 |
電流(liu)傳感器器損壞(huai) |
檢查電流傳感器是否有±2V以上的輸出信號,否則更換傳感器 |
|
主控板(ban)元器件損壞 |
依次更換IC210、IC211 |
|
L1、L2、L3不周期性閃爍,其它各燈正常 |
主控板元器件損壞 |
依次更換IC210、IC211、IC205、IC207 |
L6滅,其它各燈正常 |
主控板元器(qi)件(jian)損壞(huai) |
依次更換IC207、IC209 |
L5滅,其它各燈正常 |
散熱器溫度檢測回路故障 |
檢查溫度開(kai)關(guan)及其連線 |
L4、L7、L8全部或部分滅 |
電源(yuan)故障 |
1、檢查變壓器及控制板是否有±18V電源 2、更換相應的7805、7815、7915 |
F1-L1~L6 或F2-L1~L6部分指示燈亮,主板各燈正常 |
觸發板元器件損壞 |
1、有一片ULN2004損壞,更換之 2、脈沖變壓器接觸不良,作相應處理 |
F1-L1~L6 或F2-L1~L6指示燈全滅,主板各燈正常 |
觸(chu)發板元器件損(sun)壞(huai) |
1、兩片ULN2004損壞,更換之 2、更換555芯片 |
觸發板無電(dian)源(yuan) |
1、檢查主板7815是否有虛焊 2、檢查觸發板19腳與主板6腳連接是否正常 |
十(shi)三注意事項
1、進相器檢(jian)修應在退相狀(zhuang)態下進行(xing),發現問題(ti)應立即退相。
2、嚴禁隨意帶(dai)電插(cha)拔控制板,檢(jian)修控制板時,一定要把空開QF3打下來。
3、更換可控(kong)硅(gui)時應注意陰、陽極的方向,并壓(ya)緊(jin)散熱器(壓(ya)力不要過大),裝(zhuang)上(shang)后(hou)擰緊(jin)所有螺絲,之后(hou)再檢測可控(kong)硅(gui)各(ge)極間的電阻情況。若一只可控(kong)硅(gui)擊穿(chuan)在柜(ju)體上(shang)直(zhi)接檢測,同一相的四個可控(kong)硅(gui)均顯示(shi)擊穿(chuan),此時應把該組可控(kong)硅(gui)間的聯接銅排(pai)拆(chai)掉再測 。
十四(si)訂貨須知(zhi)
1、提供電(dian)(dian)機型(xing)號、額定(ding)功率(lv)、定(ding)子(zi)(zi)電(dian)(dian)壓、定(ding)子(zi)(zi)電(dian)(dian)流、轉(zhuan)子(zi)(zi)電(dian)(dian)壓、轉(zhuan)子(zi)(zi)電(dian)(dian)流、額定(ding)功率(lv)因數。
2、提供電機(ji)拖動(dong)負載的特征及負載率。
預(yu)知TP系列無環流靜止式進相器的(de)更多信息,請撥打襄陽拓邦電(dian)氣(qi)官網(wang)電(dian)話: 鄭經理17771133316或咨(zi)詢網(wang)站客(ke)服(fu)!!